G5SB PCB Power Relay Compact Single-pole Relay for Switching 5 A Compact SPDT Relay Incorporates a normally open contact that switches 5 A max. (N.O. contacts) Small, yet provides 8-kV impulse withstand voltage (between coil and contacts) Standard model conforms to UL/CSA/VDE standards. RoHS Compliant Model Number Legend Application Examples Ideal for output applications of control equipments 1. Number of Poles 2. Enclosure rating G G5SB-14 5 1: 1-pole/SPDT (1c) 4: Fully sealed 12 S B Ordering Information Characteristics Contact resistance *1 100 m max. Contact Terminal Enclosure Rated coil Minimum Classification Model form Shape rating voltage packing unit Operate time 10 ms max. Release time 5 ms max. 5 VDC Insulation resistance *2 1,000 M min. 9 VDC SPDT PCB Fully 100 pcs/ Between coil Standard G5SB-14 (1c) terminals sealed Tray 4,000 VAC, 50/60 Hz for 1 min 12 VDC and contacts Dielectric 24 VDC Between strength contacts of the 1,000 VAC, 50/60 Hz for 1 min Note. When ordering, add the rated coil voltage to the model number. same polarity Example: G5SB-14 DC12 Impulse Between coil Rated coil voltage withstand 8 kV (1.2 x 50 s) However, the notation of the coil voltage on the product case as well as and contacts voltage on the packing will be marked as VDC. Insulation Between coil Clearance: 3.5 mm, Creepage: 6.5 mm distance and contacts Ratings 10 to 55 to 10 Hz, 0.75 mm single amplitude Destruction Vibration (1.5 mm double amplitude) Coil resistance 10 to 55 to 10 Hz, 0.75 mm single amplitude Malfunction (1.5 mm double amplitude) Item Must Must 2 Max. Destruction 1,000 m/s Shock operate release Rated Coil Power voltage 2 resistance Malfunction 100 m/s voltage voltage current resistance consumption (V) 5,000,000 operations (V) (V) (mA) () (mW) Rated Mechanical (18,000 operations per hour) voltage % of rated voltage 200,000 operations: 3 A (NO)/3 A (NC) at 5 VDC 80 63 125 VAC 150% 50,000 operations: 5 A (NO)/3 A (NC) at 9 VDC 44.4 202 75% 5% min. (at Approx. 400 Durability 125 VAC max. 12 VDC 33.3 360 Electrical 23C) 50,000 operations: 5 A (NO) at 250 VAC (resistive load) 24 VDC 16.7 1,440 100,000 operations: 3 A (NC) at 250 VAC 100,000 operations: 5 A (NO)/3 A (NC) at Note 1. The rated current and coil resistance are measured at a coil 30 VDC temperature of 23C with a tolerance of 10%. Switching frequency: 1,800 operations per hour Note 2. The operating characteristics are measured at a coil temperature of 23C. Failure rate (P level) Note 3. The Max. voltage is the maximum voltage that can be applied to the relay coil. 10 mA at 5 VDC (reference value) *3 Contacts Ambient operating 40C to 70C with no icing or condensation temperature Item Load Resistive load Ambient operating humidity 5% to 85% Contact type Single Weight Approx. 6.5 g Contact material Ag-alloy (Cd free) Note. The data shown above are initial values. 3 A (NO)/3 A (NC) at 125 VAC *1. The contact resistance is possible with 1 A applied at 5 VDC using a fall- 5 A (NO)/3 A (NC) at 125 VAC of-potential method. Rated load 5 A (NO) at 250 VAC *2. The insulation resistance is possible between coil and contacts and 3 A (NC) at 250 VAC between contacts of the same polarity at 500 VDC. 5 A (NO)/3 A (NC) at 30 VDC *3. This value was measured at a switching frequency of 120 operations/min. Rated carry current 5 A (NO)/3 A (NC) Max. switching voltage 250 VAC, 30 VDC Max. switching current 5 A (NO)/3 A (NC) 1G5SB PCB Power Relay Engineering Data Maximum Switching Capacity Ambient Temperature vs. Maximum Voltage 7 200 180 6 AC resistive (NO) 160 5 140 120 DC resistive 4 AC resistive 110 (NO) (NC) 100 3 80 DC resistive 60 2 (NC) 40 1 20 0 0 1 10 30 100 250 1,000 -40 -20 0 23 40 60 70 80 100 Note. The maximum voltage is the maximum voltage that can be applied to the relay cooil. Switching voltage (V) Ambient temperature (C) Ambient Temperature vs Must Shock Malfunction Operate and Must Release Voltages Y 100 1,000 Sample: Must operate voltage NO contact 90 G2RL-14-E 24 VDC Must release voltage Sample: G5SB-14 12 VDC Number of Relays: 5 pcs Number of Relays: 5 pcs 80 X Z NC contact Conditions: Shock is applied in X, Y, Z G 1,000 1,000 70 max. directions three times each with and without 5 X energizing the Relays to check the number 60 S min. of malfunctions. B 50 2 250 Requirement: None malfunction 100 m/s 40 1,000 1,000 Z X 30 650 20 max. Shock direction X XX 1,000 2 10 min. Unit: m/s Y Y Z -30 -20 -10 0 102030405060708090 Z Y Ambient temperature (C) Dimensions (Unit: mm) PCB Mounting Holes Terminal Arrangement/ G5SB-14 (Bottom View) Internal Connections Tolerance: 0.1 mm (Bottom View) 10.3max. (10.0)* 20.3max. (20.0)* 2.54 Five, 1.30.1-dia. holes (1.19) 2.54 15.8max. (15.5)* 1 23 7.62 0.4 5 4 0.4 0.27 1 3.4 (No coil polarity) 10.16 2.54 5.08 7.62 (1.18) 10.16 2.54 5.08 *Values in parentheses are average values. Approved Standards UL Recognized: (File No. E41515) CSA Certified: (File No. LR31928) Number of test Model Coil ratings Contact ratings operations 5A 250V AC N.O. only (Resistive) 40C 3A 125V AC N.O. only (Resistive) 40C G5SB 12 to 24 VDC 5A 30V DC N.O. only (Resistive) 40C 6,000 3A 250V AC N.C. only (Resistive) 40C 2A 125V AC N.C. only (Resistive) 40C EN/IEC, VDE Certified: (Certificate No. 40003957) Number of test Model Coil ratings Contact ratings operations G5SB 12, 24 VDC 5A(N.O)/3A(N.C) 250V AC 70C 10,000 Precautions Please refer to PCB Relays Common Precautions for correct use. 2 Must operate/must release voltage (percentage of rated voltage) (%) Switching current (A) Maximum voltage (%)