- G5V-2 Low Signal Relay General-purpose, Low-cost, Two-pole Relays for Signal Circults General-purpose DIL terminal layout. Wide switching power of 10 A to 2 A. Fully-sealed type Relays standardized with bifurcated crossbar contacts. Highly reliable in addition to its high environment resistance. Conforms to FCC Part 68 (impulse withstand voltage of 1,500 V for 10 x 160 s between coil and contacts and between contacts of the same polarity). High dielectric strength at 1,000 VAC between coil and contacts, and 750 VAC between contacts of the same polarity. UL and CSA standard approved. RoHS Compliant Model Number Legend Application Examples 1. Number of Poles/ Contact form 2. Classification Telecommunication equipment G5V- - 2: 2-pole/DPDT (2c) None: Standard Security equipment 12 H1: High-sensitivity Ordering Information Ratings G Minimum Coil 5 Enclosure Contact Terminal Rated coil Model packing V rating form shape voltage Must Must Classification unit Max. Rated Coil operate release Power 2 3 VDC Rated voltage voltage voltage Classification current resistance consumption 5 VDC (V) voltage (mA) () (V) (V) (mW) 6 VDC % of rated voltage Standard G5V-2 9 VDC 12 VDC 3 VDC 166.7 18 PCB Fully DPDT 25 24 VDC 5 VDC 100 50 sealed (2c) pcs/tube terminals 48 VDC 6 VDC 83.3 72 Approx. 500 75% 5% 120% 5 VDC Standard 9 VDC 55.6 162 max. min. (at 23C) 12 VDC High- G5V-2-H1 12 VDC 41.7 288 sensitivity 24 VDC 24 VDC 20.8 1,152 48 VDC 48 VDC 12 4,000 Approx. 580 Note: When ordering, add the rated coil voltage to the model number. 5 VDC 30 166.7 Example: G5V-2 3 VDC 180% Approx. 150 Rated coil voltage 12 VDC 12.5 960 High- 75% 5% (at 23C) 24 VDC 8.33 2,880 Approx. 200 sensitivity max. min. Characteristics 150% 48 VDC 6.25 7,680 Approx. 300 (at 23C) Item Classification Standard High-sensitivity Note 1. The rated current and coil resistance are measured at a coil Contact resistance *1 50 m max. 100 m max. temperature of 23C with a tolerance of 10%. Operate time 7 ms max. 2.Operating characteristics are measured at a coil temperature of 23C. Release time 3 ms max. 3. The maximum voltage is the highest voltage that can be imposed on the Insulation resistance *2 1,000 M min. (at 500 VDC) relay coil. Between coil and 1,000 VAC, 50/60 Hz for 1 min contacts Contacts Dielectric Between contacts 750 VAC, 50/60 Hz 500 VAC, 50/60 Hz for Classification Standard High-sensitivity strength of the same polarity for 1 min 1min Load Resistive load Between contacts 1,000 VAC, 50/60 Hz for 1 min Contact type Bifurcated crossbar of different polarity 10 to 55 to 10 Hz, 0.75 mm single amplitude Contact material Ag + Au-alloy Destruction (1.5 mm double amplitude) Vibration 0.5 A at 125 VAC 0.5 A at 125 VAC Rated load resistance 10 to 55 to 10 Hz, 0.75 mm single amplitude 2 A at 30 VDC 1 A at 24 VDC Malfunction (1.5 mm double amplitude) Rated carry current 2 A 2 Shock Destruction 1,000 m/s Max. switching voltage 125 VAC, 125 VDC 2 2 resistance Malfunction 200 m/s 100 m/s Max. switching current 2 A 1 A 15,000,000 operations min. Mechanical (at 36,000 operations/hr) AC: 100,000 operations Durability 100,000 operations min., DC: 300,000 Electrical min. (at 1,800 operations min. operations/hr) (at 1,800 operations/hr) Failure rate (P level) (reference 10 A at 10 m VDC value) *3 -25C to 65C -25C to 70C Ambient operating temperature (with no icing or (with no icing or condensation) condensation) Ambient operating humidity 5% to 85% Weight Approx. 5 g Note: The above values are initial values. *1. The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method. *2. The insulation resistance was measured with a 500 VDC megohmmeter applied to the same parts as those used for checking the dielectric strength. *3. This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 50 . This value may vary depending on the switching frequency and operating environment. Always double-check relay suitability under actual operating conditions. 1- G5V-2 Low Signal Relay Engineering Data Maximum Switching Capacity Durability Standard/G5V-2 High-sensitivity/G5V-2-H1 Standard/G5V-2 High-sensitivity/G5V-2-H1 5 100 5 100 24 VDC resistive load 3 50 50 30 VDC resistive load 2 AC resistive load 30 30 1 AC resistive load 1 125 VAC resistive load 0.7 10 10 0.5 0.5 DC resistive load 5 125 VAC resistive load 5 DC resistive load 0.3 3 3 0.2 0.1 0.1 1 1 0 10 30 50 100 300 500 0 1 2 3 0 10 30 50 70 125 300 500 0.5 1 1.5 Switching voltage (V) Switching current (A) Switching voltage (V) Switching current (A) Ambient Temperature vs. Maximum Coil Voltage Standard/G5V-2 High-sensitivity/G5V-2-H1 160 200 3 to 24 VDC 180 140 3 to 24 VDC 160 120 140 100 120 48 VDC 48 VDC 80 100 G 60 80 5 V 0 20 40 60 80 100 120 0 20 40 60 80 Ambient temperature (C) Ambient temperature (C) 2 Note: The maximum coil voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage. Ambient Temperature vs. Must Operate or Must Release Voltage Shock Malfunction Standard/G5V-2 High-sensitivity/G5V-2-H1 Standard/G5V-2 High-sensitivity/G5V-2-H1 100 100 Y Y 1,000 1,000 Sample: G5V-2 Sample: G5V-2-H1 Number of Relays: 10 pcs Number of Relays: 10 pcs max. 800 800 max. X 80 80 X 600 600 min. min. X Z X Z 1,000 1,000 1,000 1,000 400 400 200 200 60 60 200 200 max. X 40 40 De- De- 400 400 max. min. 1,000 1,000 1,000 1,000 energized energized X Z X Z X 600 600 min. 800 800 20 20 Shock direction Shock direction X X X X Energized Energized Must operate voltage Must operate voltage 1,000 1,000 Y Y Y Y Must release voltage Must release voltage 2 Z 2 0 0 Z Unit: m/s Unit: m/s -60 -40 -20 0 20 40 60 80 100 120 -60 -40 -20 0 20 40 60 80 100 120 Z Sample: G5V-2 12 VDC Sample: G5V-2-H1 12 VDC Z Y Y Number of Relays: 10 pcs Number of Relays: 10 pcs Ambient temperature (C) Ambient temperature (C) Conditions: Shock is applied in X, Y, and Z directions three times each with and without energizing the Relays to check the number of contact malfunctions. Dial Pulse Test (with Must Operate and Must Release Voltage) *1 Dial Pulse Test Contact Reliability Test *1, *2 Standard/G5V-2 (Contact Resistance) *1 Standard/G5V-2 High-sensitivity/G5V-2-H1 100 1,000 1,000 1,000 Sample: G5V-2 Sample: G5V-2-H1 Sample: G5V-2 Sample: G5V-2 NO contact Number of Relays: 10 pcs Number of Relays: 10 pcs Number of Relays: 10 pcs Number of Relays: 10 pcs max. Test conditions: 10 A resistive load at 10 mVDC Test conditions: 10 A resistive load at 10 mVDC Test conditions: Contact load WJ-926 500 Test conditions: Contact NC contact 500 500 Switching frequency: 1,800 operations/h load WJ-926 Switching frequency: 7,200 operations/h Switching frequency: 7,200 operations/h 80 Switching frequency: 300 300 300 1,800 operations/h Must operate voltage NO contact NO contact max. max. 60 max. NC contact NC contact min. 100 100 100 max. max. 40 max. 50 50 50 min. Must release voltage min. min. 30 30 30 min. 20 max. min. min. min. 10 10 10 0 0.3 0.5 1 3 5 10 30 50 100 300 0 0.3 0.5 1 3 5 10 30 50 100 300 0 5 10 50 100 500 1,000 0 5 10 50 100 500 1,000 3 3 4 Operating frequency (10 operations) Operating frequency (10 operations) Operating frequency (10 operations) 4 Operating frequency (10 operations) *1. The tests were conducted at an ambient temperature of 23C. *2. The contact resistance data are periodically measured reference values and are not values from each monitoring operation. Contact resistance values will vary according to the switching frequency and operating environment, so be sure to check operation under the actual operating conditions before use. 2 Switching current (A) Maximum coil voltage (%) On the basis of rated voltage (%) On the basis of rated voltage (%) Contact resistance (m ) Maximum coil voltage (%) Switching current (A) On the basis of rated voltage (%) Contact resistance (m ) 4 Durability (x10 operations) Contact resistance (m) 4 Durability (x10 operations)