Low Signal Relay G6A Fullly Sealed Relay with High Impulse Withstand High sensitivity can be driven by digital circuits. Low-profile design allows use in 12.70 mm PC board rack. Surge withstand voltage meet s FCC Part 68 regulation. Units can be mounted side by side due to low magnetic leakage. Special models available for low thermoelectromotive force. Unique moving loop (permanent magnet) armature reduces relay size, magnetic interference, and contact bounce time. Single or dual coil winding types available. RoHS Compliant RC FCC Ordering Information To Order: Select the part number and add the desired coil voltage rating, (e.g., G6A-274P-ST-US-DC12). Non-latching Type Contact form Model Ag (Au clad) Standard DPDT G6A-274P-ST-US 4PDT - DISCONTINUED G6A-474P-ST-US Low-sensitivity DPDT G6A-274P-ST40-US 4PDT - DISCONTINUED G6A-474P-ST40-US Latching Single Coil Type Contact form Model Ag (Au clad) Standard DPDT G6AU-274P-ST-US 4PDT - DISCONTINUED G6AU-474P-ST-US Dual Coil Type Contact form Model Ag (Au clad) Standard DPDT G6AK-274P-ST-US 4PDT - DISCONTINUED G6AK-474P-ST-US Low-sensitivity DPDT G6AK-274P-ST40-US 4PDT - DISCONTINUED G6AK-474P-ST40-US Low Signal Relay G6A 81Specifications Contact Data Type G6A-274P-ST(40)-US, G6A-474P-ST(40)-US G6AK-274P-ST(40)-US, G6AK-474P-ST(40)-US G6AU-274P-ST-US, G6AU-474P-ST-US Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.4) (L/R = 7 ms) Rated load 0.50 A at 125 VAC, 0.3 A* at 125 VAC, 2 A at 30 VDC 1 A at 30 VDC Contact material Ag (Au clad) Carry current 3 A Max. operating voltage 250 VAC, 220 VDC Max. operating current 2 A 1 A Max. switching capacity 125 VA, 60 W 62.50 VA, 30 W Min. permissible load (See note) 10 A, 10 mVDC * 0.25A at 125VAC for latching models 6 Note: 1. P level: = 0.1 x 10 /operation 60 This value was measured at a switching frequency of 60 operations/min and the criterion of contact resistance is 50 . This value may vary depending on the switching frequency and operating environment. Always double-check relay suitability under actual operating con- ditions. 2. G6A-4 pole versions are discontinued. Coil Data Standard Non-latching DPDT (G6A-274P-ST-US) Rated Rated Coil Coil inductance Pick-up Dropout Maximum Power voltage current resistance (ref. value) (H) voltage voltage voltage consumption (VDC) (mA) ( ) (mW) Armature Armature % of rated voltage OFF ON 3 66.70 45 0.07 0.065 70% max. 10% min. 200% Approx. 200 at 23 C 4.5 44.6 101 0.16 0.14 5 40 125 0.20 0.18 6 33.30 180 0.29 0.26 9 22.20 405 0.63 0.57 12 16.70 720 1.10 1.06 24 8.30 2,880 4.50 4.10 48 4.90 9,750 13.70 12.50 Approx. 235 Low-sensitivity Non-latching DPDT (G6A-274P-ST40-US) Rated Rated Coil Coil inductance Pick-up Dropout Maximum Power voltage current resistance (ref. value) (H) voltage voltage voltage consumption (VDC) (mA) () (mW) Armature Armature % of rated voltage OFF ON 3 133.30 22.50 0.03 0.02 70% max. 10% min. 150% Approx. 400 at 23 C 4.5 88.9 50.6 0.065 0.06 5 80 62.50 0.08 0.07 6 66.70 90 0.11 0.10 9 44.30 203 0.27 0.23 12 33.30 360 0.52 0.43 24 16.70 1,440 2.10 1.80 48 8.30 5,760 7.50 6.40 Note: 1. The rated current and coil resistance are measured at a coil temperature of 23 C with a tolerance of 10%. 2. Operating characteristics are measured at a coil temperature of 23 C. 3. The maximum voltage is the highest voltage that can be imposed on the relay coil. 82 Low Signal Relay G6A