G6A Low Signal Relay World s Standard Model G6A Resistant to electromagnetic interference, enables high-density mounting. Impulse withstand voltage of 1,500V meets FCC requirements. Gold-clad twin-contacts provide short contact bounce in addition to its high contact reliability. A variety of products th at cover a wide range of use. RoHS Compliant Model Number Legend Application Examples Telecommunication equipment 5. Terminal Shape G6A - - - G Security equipment P: PCB Terminals 123456 7 6 Medical equipment A 6. Classification Test & measurement equipment 1. Relay Function None : Standard LT : Low thermoelectromotive force None : Single-side stable U : Single-winding latching ST : Stand-off 0.64 mm K : Double-winding latching 15 : High-sensitivity (150 mW) 40 : Low-sensitivity 2. Contact Form (Single-side Stable: 400 mW 2: DPDT (2c) Double-winding Latching: 300 mW) 3. Contact Type 7. Approved Standards 7: Bifurcated crossbar Ag (Au-Alloy) None : Standard 4. Protective Structure US : UL, CSA 4: Fully sealed Ordering Information UL, CSA Certified Models Relay Function Classification Contact form Model Rated coil voltage (VDC) Minimum packing unit 3, 4.5, 5, 6, 9, 12, 24 Standard G6A-274P-ST-US 48 3, 5, 6, 9, 12, 24 Single-side Stable Low-sensitivity G6A-274P-ST40-US Type 48 3, 5, 6, 9, 12, 24 High-sensitivity G6A-274P-ST15-US 48 DPDT (2c) 25 pcs/tube 3, 4.5, 5, 6, 9, 12, 24 Single-winding Standard G6AU-274P-ST-US Latching Type 48 3, 4.5, 5, 6, 9, 12, 24 Standard G6AK-274P-ST-US 48 Double-winding Latching Type 3, 5, 6, 9, 12, 24 Low-sensitivity G6AK-274P-ST40-US 48 Note: When ordering, add the rated coil voltage to the model number. Example: G6A-274P-ST-US 3 VDC Rated coil voltage 1G6A Low Signal Relay Ratings Coil: Single-side Stable (Standard Models) Must operate voltage Must release voltage Max. voltage Rated current Coil resistance Power consumption (V) (V) (V) Contact form Rated voltage (mA) () (mW) % of rated voltage 3 VDC 66.7 45 4.5 VDC 44.6 101 5 VDC 40.0 125 6 VDC 33.3 180 Approx. 200 200% DPDT (2c) 70% max. 10% min. (at 23C) 9 VDC 22.2 405 12 VDC 16.7 720 24 VDC 8.3 2,880 48 VDC 4.9 9,750 Approx. 235 Note1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. 2. Operating characteristics are measured at a coil temperature of 23C. 3. The maximum voltage is the highest voltage that can be imposed on the relay coil. Coil: Single-side Stable (Low-sensitivity Models) Must operate voltage Must release voltage Max. voltage Rated current Coil resistance Power consumption (V) (V) (V) Contact form Rated voltage (mA) () (mW) % of rated voltage 3 VDC 133.3 22.5 5 VDC 80 62.5 G 6 VDC 66.7 90 6 150% A DPDT (2c) 9 VDC 44.3 203 70% max. 10% min. Approx. 400 (at 23C) 12 VDC 33.3 360 24 VDC 16.7 1,440 48 VDC 8.3 5,760 Note1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. 2. Operating characteristics are measured at a coil temperature of 23C. 3. The maximum voltage is the highest voltage that can be imposed on the relay coil. Coil: Single-side Stable (High-sensitivity Models) (Low Thermoelectromotive Force) Must operate voltage Must release voltage Max. voltage Rated current Coil resistance Power consumption (V) (V) (V) Contact form Rated voltage (mA) () (mW) % of rated voltage 3 VDC 50 60 4.5 VDC 33.3 135 5 VDC 30 167 6 VDC 25 240 200% DPDT (2c) 80% max. 10% min. Approx. 150 (at 23C) 9 VDC 16.7 540 12 VDC 12.5 960 24 VDC 6.3 3,840 48 VDC 3.2 15,000 Note1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. 2. Operating characteristics are measured at a coil temperature of 23C. 3. The maximum voltage is the highest voltage that can be imposed on the relay coil. Coil: Single-winding Latching Set voltage (V) Reset voltage (V) Max. voltage (V) Rated current Coil resistance Power consumption Contact form Rated voltage (mA) () (mW) % of rated voltage 3 VDC 33.7 89 5 VDC 20 250 6 VDC 16.7 360 Approx. 100 200% DPDT (2c) 9 VDC 11.1 810 70% max. 70% max. (at 23C) 12 VDC 8.3 1,440 24 VDC 4.2 5,760 48 VDC 2.5 19,000 Approx. 120 Note1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. 2. Operating characteristics are measured at a coil temperature of 23C. 3. The maximum voltage is the highest voltage that can be imposed on the relay coil. 2