Power PCB Relay
G6D-ASI
Reduced board space ideal for high-density mounting
(45% smaller than the surface area of G6B).
Slim package: measures 6.5 W x 17.5 L x 12.5 H mm
Switches loads up to 5 A, 250 VAC/30 VDC.
Sealed construction allows automatic soldering and cleaning.
Long service life: up to 300,000 operations with a 2 A,
250 VAC/30 VDC load.
Rated for D150 pilot duty by UL, CSA.
Optional mounting socket simplifies relay installation and
servicing of finished equipment.
RCE
RoHS Compliant.
Ordering Information
To Order: Select the part number and add the desired coil voltage rating, (e.g., G6D-1A-ASI-DC12).
Type Contact form Terminal Construction Model
Standard SPST-NO PCB Fully sealed G6D-1A-ASI
Accessories
Connecting Socket
Description Model
PCB mount socket for G6D relay P6D-04P
Specifications
Contact Data
Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms)
Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC
Contact material Ag alloy
Carry current 5 A
Max. operating voltage 250 VAC, 30 VDC
Max. operating current 5 A
Max. switching capacity 1,250 VA, 150 W 500 VA, 60 W
Min. permissible load 10 mA at 5 VDC
-6
Note: P level: = 0.1 x 10 /operation
60
Power PCB Relay G6D-ASI 145 Coil Data
Rated Rated Coil Pick-up Dropout Maximum Power
voltage current resistance voltage voltage voltage consumption
(VDC) (mA) () (mW)
% of rated voltage
5 40 125 70% max. 10% min. 160% at 23C Approx. 200
12 16.7 720
24 8.3 2,880
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C (73F) with a tolerance of 10%.
2. Operating characteristics are measured at a coil temperature of 23C (73F).
3. The pick-up voltage is 75% or less of rated voltage if the relay is mounted upside down.
Characteristics
Contact resistance 100 m max.
Operate time 10 ms max.
Release time 5 ms max.
Operating Mechanical 18,000 operations/hour
frequency
Electrical 1,800 operations/hour (under rated load)
Insulation resistance 1,000 M min. (at 500 VDC)
Dielectric strength 3,000 VAC, 50/60 Hz for 1 minute between coil and contacts
750 VAC, 50/60 Hz for 1 minute between contacts of the same polarity
Surge withstand voltage 6,000 V, 1.20 x 50 s between coil and contacts
Vibration Mechanical durability 10 to 55 Hz, 1.50 mm (0.06 in) double amplitude
Malfunction durability 10 to 55 Hz, 1.50 mm (0.06 in) double amplitude
2
Shock Mechanical durability
1,000 m/s (approx. 100 G)
2
Malfunction durability
100 m/s (approx. 10 G)
Ambient temperature Operating -25 to 70C (-13 to 158F)
Humidity 5% to 85% RH
Life expectancy Mechanical 20 million operations min. (at operating frequency of 18,000 operations/hour)
Electrical 70,000 operations min. at rated loads (300,000 operations min for 2A at 250 VAC, 30 VDC,
resistive load)
Weight Approx. 3 g (0.10 oz)
Note: Data shown are of initial value.
Characteristic Data
Maximum Switching Capacity Life Expectancy
Ambient Temperature vs.
Maximum Coil Voltage
50
500 200
30
300
180
100
10
160
AC resistive load
250-VAC/30-VDC resistive load
5 50
140
3 30
DC resistive
load
120
AC inductive
10
1
load
DC inductive
cos=0.4
load
100
250-VAC/30 VDC inductive load
5
0.5
(cos=0.4/ L/R=7 ms)
0.3 3
80
0.1
60
0 1 2 3 4 5 6 7 8 9 10
0 3 5 10 30 100 250 500 1,000
02330 40 50 60 70 8090
Switching current (A)
Switching voltage (V)
Ambient temperature (C)
Note: The maximum coil voltage is the
maximum voltage that can be
applied to the relay coil.
146 Power PCB Relay G6D-ASI
Switching current (A)
4
Life Expectancy (x10 operations)
Maximum coil voltage (%)