Omron 08 Cat 1-302 5/10/07 15:39 Page 62 TPCB Power Relay G6Dext Text PCBText Power Relay - G6DS Slim, Miniature Relay with 1-pole 5- Dimensions A Switching Capability Note: 1. All units are in millimetres unless otherwise indicated. 2. Orientation marks are indicated as follows: Slim 5-mm width and miniature size. (21.3 x 5.08 x 12.5 mm max.) 6.5 max. G6D-1A-ASI Terminal Arrangement/ Mounting Holes 17.5 max. 0.5 (6.4)* Internal Connections (Bottom View) (17.3)* Ideal for high-density mounting. (Bottom View) Tolerance: 0.1 Delivers high switching performance (5 A at 12.5 max. (1.13) Four, 1.1-dia. 2.54 (12.4)* holes 250 VAC/30 VDC) and enables various loads (0.71) all in a slim, miniature size. 3.5 1 57 0.5 0.8 5.08 0.3 Highly sensitive coil type (120 mW) also 2.54 7.62. 2.54 5.08 5.08 available. 13 *Average value Satisfies EN 61131-2 (PLC) and EN 61010 15.24 19.7 max. P6D-04P Socket (measuring instrument/control equipment) (19.5)* Mounting Holes (Bottom View) reinforced insulation requirement. 6.9 max. (6.7)* Tolerance: 0.1 Four, 1.1-dia. Special socket also added to the series. (2.18) 2.54 holes Applications: (0.86) PLCs, I/O modules, I/O ports, Timers, 10.8 RoHS Compliant 6+0.1 Temperature Controllers, and Control Boards. 5.08 3.6 2.54 0.65 0.3 Ordering Information 2.54 76.2 5.08 15.24 Classification Contact form Enclosure ratings Model *Average value Standard SPST-NO Fully sealed G6DS-1A High-sensitivity G6DS-1A-H Note: When ordering, add the rated coil voltage to the model number. Example: G6DS-1A 12 VDC Precautions Rated coil voltage - G6DS- VDC More than two relays can be closely mounted right side up as SOCKET MOUNTING HEIGHT shown in the following illustration. 12 3 4 3. Classification 1. Number of Poles 6.5 mm 1: 1 pole None: Standard H: High-sensitivity 18.5 mm max. 2. Contact Form A: SPST-NO 4. Rated Coil Voltage 5, 12, 24 VDC Current flow: Accessories (Order Separately) 5 A max. When mounting the relay, insert it into the socket as vertically as possible so that the relay terminals contact securely with the Connecting Socket P6DS-04P contact pins on the socket. More than two relays can be closely mounted upside down as Relay Pullout Tool R99-01 for G6DS shown in the following illustration. The P6D is flux-resistive. Do not wash the P6D with water. Dismount the relay from the socket before soldering the socket to 7.62 mm in the Coil Ratings a PCB. upside-down direction Item Standard High-sensitivity Rated voltage 5 VDC 12 VDC 24 VDC 5 VDC 12 VDC 24 VDC Rated current 36 mA 15 mA 7.5 mA 24 mA 10 mA 5 mA Coil resistance 139 800 3,200 208 1,200 4,800 Current flow: Must operate voltage 70% max. of rated voltage 2 A max. Must release voltage 5% min. of rated voltage 1.12 mm Max. voltage 160% of rated voltage (at 23C) Note: The space between each relay required for heat radiation Power consumption Approx. 180 mW Approx. 120 mW may vary with operating conditions. Contact your OMRON Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. representative for details 2. Operating characteristics are measured at a coil temperature of 23C. 3. Max. voltage refers to the maximum voltage that can be applied to the relay coil. It is not the maximum voltage that can be applied continuously. ALL DIMENSIONS SHOWN ARE IN MILLIMETRES. To convert millimetres into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. CAT. No. K127-E2-02A-X 62 63 Power RelaysOmron 08 Cat 1-302 5/10/07 15:39 Page 64 Text PCBText Power Relay - G6DS PCB Power Relay - G6DS Contact Ratings Approved Standards The rated values approved by each of the safety standards may be different from the performance characteristics individually Item Resistive load (cos=1) Inductive load (cos=0.4, L/R=7 ms) defined in this catalog. Rated load 5 A at 250 VAC, 5 A at 30 VDC 2 A at 250 VAC, 2 A at 30 VDC UL 508 (File No. E41515)/CSA C22.2 No.14 (File No. LR31928) Contact Material AgNi Model Contact form Coil ratings Contact ratings Rated carry current 5 A G6DS-1A SPST-NO 5 to 24 VDC 5 A, 250 VAC (Resistive & General Use) Max. switching voltage 250 VAC, 30 VDC 5 A, 30 VDC (Resistive & General Use) Max. switching current 5 A G6DS-1A-H 5 A, 250 VAC (Resistive & General Use) Max. switching power 1,250 VA, 150 W 5 A, 30 VDC (Resistive & General Use) Failure rate (reference value) (See note.) 5 mA at 24 VDC -6 Note: P level: 60 = 0.1 x 10 operation VDE (EN61810-1) (License No. B161) Characteristics Model Contact form Coil ratings Contact ratings Contact resistance (See note 1.) 100 m max. G6DS-1A SPST-NO 5, 12, 24 VDC 5 A, 250 VAC (cos=1.0) Operate time 10 ms max. 5 A, 30 VDC (0 ms) Release time 5 ms max. G6DS-1A-H 5 A, 250 VAC (cos=1.0) Insulation resistance (See note 2.) 1,000 M min. (at 500 VDC) 5 A, 30 VDC (0 ms) Dielectric strength 3,000 VAC, 50/60 Hz for 1 min between coil and contacts 750 VAC, 50/60 Hz for 1 min between contacts of same polarity Dimensions Impulse withstand voltage 6,000 V (1.2 x 50 s) between coil and contacts Note: All units are in millimetres unless otherwise indicated. Insulation Creepage (Typ) 6.4mm Distance Clearance (Typ) 5.2mm Terminal Arrangement/ G6DS-1A/1A-H Internal Connections Tracking Resistance (CTI) 175V (Bottom View) Vibration resistance Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) 2 21.3 max. Shock resistance Destruction: 1,000 m/s 2 2 Malfunction: 150 m/s (standard type). 130 m/s (high-sensitivity type) 5.08 max. 20 Endurance Mechanical: 20,000,000 operations min. (at 18,000 operations/hr) Mounting Holes Electrical: 100,000 operations min. (at 1,800 operations/hr) for standard type. (Bottom View) 80,000 operations min. (at 1,800 operations/hr) for high-sensitivity type. (at 23C) 10.160.1 5.080.1 Ambient temperature Operating: -40C to 85C (with no icing) 2.540.1 Ambient humidity Operating: 5% to 85% (1.11) (1.11) Weight Approx. 2.3 g Note: The data shown above are initial values. 1. The contact resistance is possible with 1 A applied at 5 VDC using a fall-of-potential method. 0.3 0.3 0.8 2. The insulation resistance is possible between coil and contacts and between contacts of the same polarity at 500 VDC. 0.3 0.3 0.6 Engineering Data Maximum Switching Power Endurance Ambient Temperature vs. Maximum Coil Voltage 22.5 max. 50 500 200 Connecting Socket 30 300 P6DS-04P 180 10 100 160 AC resistive load 250-VAC/30-VDC resistive load 5 50 140 3 30 Standard type Mounting Holes DC resistive load High-sensitivity type (Bottom View) 120 AC inductive 1 10 DC inductive load cos=0.4 load 100 250-VAC/30 VDC inductive load 0.5 5 17.780.05 (cos=0.4/ L/R=7 ms) 0.3 3 80 12.70.05 0.1 60 0 3 5 10 30 100 250 500 1,000 0 1 2 3 4 5 6 7 8 9 10 0 23 30 40 50 60 70 80 85 90 2.540.05 Switching voltage (V) Switching current (A) Ambient temperature (C) (2.31) Note: The maximum coil voltage is the maximum voltage that can be applied to the relay coil. Ambient Temperature vs. Malfunctioning Shock Operating/Recovery Voltage G6DS-1A G6DS-1A Four, 1.1 dia. 90 Energized Y Not energized 1000 80 max. 800 ave. 70 (2.31) 600 X Z min. 0.6 60 400 0.3 200 50 0 10.16 5.08 40 2.54 Shock direction 30 XX Z X Y Z 20 max. Z Relay Pullout Tool ave. Y 10 min. 2 Coil terminals Units: m/s Y R99-01 for G6DS 0 60 40 20 0 20 40 60 80 100 Measurement conditions: Impose a shock in the X, Y, and A convenient removal pullout tool (R99-01 for G6DS) is available to pull Relays out of special sockets mounted closely side by side. Z directions three times each with the Relay energized to Ambient temperature (C) check the shock values that cause the Relay to malfunction. 64 65 Four, 1.1 dia. Ratio of rated voltage (%) Switching current (A) 4 Endurance (x10 operations) Maximum coil voltage (%) 0 5.55 max. 6.1 0.1 3.3 3.65 14.8 max. 12.5 max. (1.2) 2.540.05 (1.4) (1.46) (1.26) 2.540.1 Power Relays