G6RL PCB Power Relay Low-profile 12.3 mm height power relay with maximum switching of 10A Low profile: 12.3 mm in height Max. switching capacity: 2,500 VA (NO) Dielectric strength: 5 kV Clearance and creepage distance: 10 mm. 2 Models with high shock resistance (250 m/s ) are available. Models for P1 load (2 x 200 W lamps parallel to ignition transformer) are available. RoHS Compliant Model Number Legend Application Examples Boilers G6RL- - - 12 3 4 5 PLCs 1. Number of Poles 4. Contact material I/O ports G 6 1: 1-pole None: Standard (Ag-alloy, Cd free) Timers R ASI: AgSnIn Temperature controllers 2. Contact Form L None: SPDT (1c) 5. Special Functions A: SPST-NO (1a) PL: P1 load 3. Enclosure rating None: Flux protection 4: Fully sealed Ordering Information Classification Terminal Shape Contact form Enclosure rating Model Rated coil voltage Minimum packing unit G6RL-1A Standard G6RL-1A-ASI Flux protection 3 VDC SPST-NO (1a) P1 Load G6RL-1A-ASI-PL 5 VDC Fully sealed G6RL-1A4-ASI 6 VDC PCB terminals 100 pcs/tray Standard 12 VDC G6RL-1 24 VDC G6RL-1-ASI Flux protection SPDT (1c) 48 VDC P1 Load G6RL-1-ASI-PL Standard Fully sealed G6RL-14-ASI Note. When ordering, add the rated coil voltage to the model number. Example: G6RL-1A DC3 Rated coil voltage However, the notation of the coil voltage on the product case as well as on the packing will be marked as VDC. Ratings Coil Standard, P1 Load (-PL type) Must operate voltage Must release voltage Max. voltage Rated Voltage Rated current Coil resistance Power consumption (V) (V) (V) (VDC) (mA) () (mW) % of rated voltage 3 73.3 40 5 44.0 113 6 36.7 Approx. 220 163 150% 70% max. 10% min. (at 23C) 12 18.3 654 24 9.2 2618 48 5.0 Approx. 240 9600 Note 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. Note 2. The operating characteristics are measured at a coil temperature of 23C. Note 3. The Max. voltage is the maximum voltage that can be applied to the relay coil. 1G6RL PCB Power Relay Contacts Load Resistive load Contacts type Single Contacts material Ag-alloy (Cd free) 10 A at 250 VAC, (NO) resistive load Rated load * 8 A at 250 VAC, resistive load 5 A at 30 VDC, resistive load Rated carry current 10 A Max. switching current NO: 10 A, NC: 8 A * G6RL-1(A), G6RL-1(A)4-ASI: 8 A 250 VAC, resistive load 5 A 24 VDC resistive load. Characteristics Contact resistance *1 100 m max. Operate time 10 ms max. Release time 5 ms max. Insulation resistance *2 1,000 M min. Between coil and contacts 5,000 VAC, 50/60 Hz for 1 min Dielectric strength Between contacts of the same polarity 1,000 VAC, 50/60 Hz for 1 min Impulse withstand voltage Between coil and contacts 10kV (1.250s) Insulation distance Between coil and contacts Clearance: 10 mm, Creepage: 10 mm Destruction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) Vibration resistance 10 to 55 to 10 Hz, 0.825 mm single amplitude (1.65 mm double amplitude) when energized Malfunction 10 to 55 to 10 Hz, 0.4 mm single amplitude (0.8 mm double amplitude) when de-energized. 2 Destruction 1,000 m/s Shock resistance 2 2 Malfunction NO: 200 m/s , NC: 50 m/s G Mechanical 10,000,000 operations min. (at 18,000 operations/h) 6 G6RL-1(A) R 50,000 operations min. (NO) at 250 VAC, 8A (resistive load) L 50,000 operations min. (NC) at 250 VAC, 8A (resistive load) 50,000 operations min. at 24 VDC, 5A (resistive load) (at 600 operations/h) G6RL-1(A)-ASI-(PL) 100,000 operations min. (NO) at 250 VAC, 10A (resistive load) Endurance Electrical 100,000 operations min. at 250 VAC, 8A (resistive load) 50,000 operations min. at 30 VDC, 5A (resistive load) (at 1,800 operations/h) G6RL-1(A)4-ASI 50,000 operations min. (NO) at 250 VAC, 8A (resistive load) 50,000 operations min. (NC) at 250 VAC, 8A (resistive load) 50,000 operations min. at 24 VDC, 5A (resistive load) (at 1,800 operations/h) Failure rate (P level) (reference value) *3 10 mA at 5 VDC Ambient operating temperature -40C to 85C (with no icing or condensation) Ambient operating humidity 5% to 85% Weight Approx. 7.8 g Note. The given values are initial values. *1. Measurement conditions: 5 VDC, 1 A, voltage drop method. *2. Measurement conditions: The insulation resistance was measured with a 500 VDC megohmmeter at the same locations as the dielectric strength was measured. *3. This value was measured at a switching frequency of 120 operations/min. 2