DISCONTINUED
Low Signal Relay
G6H
Ultra-compact, Ultra-sensitive DPDT Relay
Compact size and low 5 mm profile.
Low thermoelectromotive force.
Low magnetic interference enables high-density mounting.
Utilizes Omrons moving-loop design.
Highly stable magnetic circuit for latching endurance and
excellent resistance to vibration and shock.
High sensitivity with low nominal power consumption.
Single or dual coil latching types available.
RoHS Compliant
RC
Ordering Information
To Order: Select the part number and add the desired coil voltage rating, (e.g., G6H-2-DC6).
Non-latching
Terminal Type Contact form Model
Through-hole DPDT G6H-2
Surface mount G6H-2F
Latching
Terminal Type Contact form Model
Single coil latching Dual coil latching
Through-hole DPDT G6HU-2 G6HK-2
Specifications
Contact Data
Load Resistive load (p.f. = 1)
Rated load 0.50 A at 125 VAC, 1 A at 30 VDC
Contact material Ag (Au clad)
Carry current 1 A
Max. operating voltage 125 VAC, 110 VDC
Max. operating current 1 A
Max. switching capacity 62.50 VA, 33 W
Min. permissible load (See note) 10 A, 10 mVDC
6
Note: P level: = 0.1 x 10 /operation
60
This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 50 . This value may vary
depending on the operating environment. Always double-check relay suitability under actual operating conditions.
Low Signal Relay G6H 49DISCONTINUED
Coil Data
Non-latching Type (G6H-2, G6H-2F)
Rated voltage Rated current Coil Coil inductance Pick-up Dropout Maximum Power
(VDC) (mA) resistance (ref. value) (H) voltage voltage voltage consumption
() (mW)
Armature Armature % of rated voltage
OFF ON
3 46.70 64.30 0.025 0.022 75% max. 10% min. 200% max. at Approx. 140
23C
5 28.10 178 0.065 0.058
6 23.30 257 0.11 0.09
9 15.50 579 0.24 0.20
12 11.70 1,028 0.43 0.37
24 8.30 2,880 1.20 1.0 170% max. at Approx. 200
23C
48 5.8 8,228 140% max. at Approx. 300
23C
Single Coil Latching Type (G6HU-2)
Rated voltage Rated current Coil Coil inductance Set pick-up Reset pick-up Maximum Power
(VDC) (mA) resistance (ref. value) (H) voltage voltage voltage consumption
() (mW)
Armature Armature % of rated voltage
OFF ON
3 33.30 90 0.034 0.029 75% max. 75% max. 180% max. at Approx. 100
23C
5 20 250 0.11 0.09
6 16.70 360 0.14 0.12
9 11.10 810 0.33 0.28
12 8.30 1,440 0.60 0.50
24 6.25 3,840 1.6 1.3 Approx. 150
Dual Coil Latching Type (G6HK-2)
Rated voltage Rated current Coil Coil inductance Set pick-up Reset pick-up Maximum Power
(VDC) (mA) resistance (ref. value) (H) voltage voltage voltage consumption
() (mW)
Armature Armature % of rated voltage
OFF ON
3 66.70 45 0.014 0.0075 75% max. 75% max. 160% max. at Approx. 200
23C
5 40 125 0.042 0.023
6 33.30 180 0.065 0.035
9 22.20 405 0.16 0.086
12 16.70 720 0.3 0.16
24 12.50 1,920 0.63 0.33 130% max. at Approx. 300
23C
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%.
2. Operating characteristics are measured at a coil temperature of 23C with a tolerance of 10%.
3. The maximum voltage is the highest voltage that can be imposed on the relay coil.
4. The maximum voltage that can be be applied when using the G6H-2F (at 85C) is 115% (3 to 12 V) or 105% (24 V) of the rated voltage.
50 Low Signal Relay G6H