- G6J-Y Surface-mounting Relay Ultra-compact and Slim DPDT Relay Suitable for high-density mounting.(5.7 mm (W) 10.6 mm (L) 9 mm (H)). Dielectric strength of 1,500 VAC and an impulse withstand voltage of 2,500 V for 2 10 s (conforms to Telcordia specifications (formerly Bellcore)). Conforms to FCC Part 68 (1,500 V, 10 160 s). Single-winding latching models to save energy. Standard models conforms to UL/C-UL standards. RoHS Compliant Model Number Legend Application Examples Communication equipment G6J - - Test & measurement equipment 123 4 G Office automation equipment 1. Relay function 3. Terminal Shape 6 Audio-visual products None : Single-side stable relay P : PCB terminals J Security equipment U : Single-winding latching relay FS: Surface-mounting terminals, short Y Building automation equipment FL : Surface-mounting terminals, long 2. Number of contact poles/ Industrial equipment Contact form 4. Special function Amusement equipment 2: 2-pole/DPDT (2c) Y: Improved product for soldering heat resistance Ordering Information Packing Tube Packing Tape Packing Minimum Protective Rated coil Minimun Rated coil Minimum ordering unit Relay Function Structure Contact form Model voltage packing unit Model voltage packing unit (tape packing) 3 VDC 3 VDC 4.5 VDC 4.5 VDC G6J-2P-Y 5 VDC 5 VDC 12 VDC 12 VDC 24 VDC 24 VDC Single-side stable 3 VDC 3 VDC 4.5 VDC 4.5 VDC G6J-2FS-Y G6J-2FS-Y-TR 5 VDC 5 VDC G6J-2FL-Y G6J-2FL-Y-TR 12 VDC 12 VDC DPDT 800 pcs/ Fully sealed 24 VDC 50 pcs/tube 24 VDC 400 pcs/reel (2c) 2 reels 3 VDC 3 VDC 4.5 VDC 4.5 VDC G6JU-2P-Y 5 VDC 5 VDC 12 VDC 12 VDC Single-winding 24 VDC 24 VDC latching 3 VDC 3 VDC 4.5 VDC 4.5 VDC G6JU-2FS-Y G6JU-2FS-Y-TR G6JU-2FL-Y G6JU-2FL-Y-TR 5 VDC 5 VDC 12 VDC 12 VDC Note 1. When ordering, add the rated coil voltage to the model number. Example: G6J-2P-Y DC3 Rated coil voltage However, the notation of the coil voltage on the product case as well as on the packing will be marked as VDC. Note 2. When ordering tape packing, add -T to the model number. Be sure since -T is not part of the relay model number, it is not marked on the relay case. When ordering tape packing, minimum order unit is 2 reels (400 pcs 2 = 800 pcs). Note 3. Surface mounting terminal (SMT) standard models are shipped in moisture-proof package. PCB terminal standard types do not require moisture proof packaging and therefore shipped in non-moisture-proof package. 1- G6J-Y Surface-mounting Relay Ratings Coil: Single-side Stable Relays (G6J-2P-Y, G6J-2FS-Y, G6J-2FL-Y) Must operate voltage Must release voltage Max. voltage Item Rated current Coil resistance Power consumption (V) (V) (V) (mA) () (mW) Rated voltage % of rated voltage 3 VDC 48.0 62.5 4.5 VDC 32.6 137.9 Approx. 140 5 VDC 28.9 173.1 75% max. 10% min. 150% 12 VDC 12.3 976.8 24 VDC 9.2 2,600.5 Approx. 230 Note 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. Note 2. The operating characteristics are measured at a coil temperature of 23C. Note 3. The maximum voltage is the highest voltage that can be imposed on the Relay coil instantaneously. Coil: Single-winding Latching Relays (G6JU-2P-Y, G6JU-2FS-Y, G6JU-2FL-Y) Must set voltage Must reset voltage Max. voltage Item (V) (V) (V) Rated current Coil resistance Power consumption Rated voltage (mA) () % of rated voltage (mW) 3 VDC 33.7 89.0 4.5 VDC 22.0 204.3 75% max. 75% max. 150% Approx. 100 5 VDC 20.4 245.5 12 VDC 9.0 1,329.2 Note 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. Note 2. The operating characteristics are measured at a coil temperature of 23C. G Note 3. The maximum voltage is the highest voltage that can be imposed on the Relay coil instantaneously. 6 J Contacts Y Item Load Resistive load Contact type Bifurcated crossbar Contact material Ag (Au-Alloy) 0.3 A at 125 VAC, Rated load 1 A at 30 VDC Rated carry current 1 A Max. switching voltage 125 VAC, 110 VDC Max. switching current 1 A Characteristics Classification Single-side stable Single-winding latching Item Model G6J-2P-Y, G6J-2FS-Y, G6J-2FL-Y G6JU-2P-Y, G6JU-2FS-Y, G6JU-2FL-Y Contact resistance *1 100 m max. Operating (set) time 3 ms max. Release (reset) time 3 ms max. Min. set/reset signal width 10 ms Insulation resistance *2 1,000 M min. (at 500 VDC) Between coil and contacts 1,500 VAC, 50/60 Hz for 1 min Dielectric strength Between contacts of different polarity 1,000 VAC, 50/60 Hz for 1 min Between contacts of the same polarity 750 VAC, 50/60 Hz for 1 min Between coil and contacts 2,500 VAC, 2 10 s Impulse withstand Between contacts of different polarity voltage 1,500 VAC, 10 160 s Between contacts of the same polarity Destruction 10 to 55 to 10 Hz 2.5 mm single amplitude (5 mm double amplitude) Vibration resistance Malfunction 10 to 55 to 10 Hz 1.65 mm single amplitude (3.3 mm double amplitude) 2 Destruction 1,000 m/s Shock resistance 2 Malfunction 750 m/s Mechanical 50,000,000 operations min. (at 36,000 operations/hour) Durability Electrical 100,000 operations min. (with a rated load at 1,800 operations/hour) Failure rate (P level) (reference value) *3 10 A at 10 mVDC Ambient operating temperature -40 to 85C (with no icing or condensation) Ambient operating humidity 5% to 85% Weight Approx. 1.0 g Note: The above values are initial values. *1. The contact resistance was measured with 10 mA at 1 VDC with a fall-of-potential method. *2. The insulation resistance was measured with a 500 VDC Megger Tester applied to the same parts as those for checking the dielectric strength. *3. This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 50 . This value may vary depending on the operating frequency, operating conditions, expected reliability level of the relay, etc. Always double-check relay suitability under actual load conditions. 2