Low Signal Relay G6K Compact design, offers excellent board space savings. Available in 2.54 and 3.2 mm coil-contact terminal spacing. -Y models meet 2.5 kV Telcordia surge requirements of 2,500V for 2 x 10s. Conforms to FCC Part 68 surge requirements of 1,500V for 10 x 160s. Available in PCB through-hole, SMT gullwing and SMT inside-L terminals. UL recognized / CSA and BSI (EN60950) certified. Available in single coil latching. Rated Carry Current: 2A. RoHS Compliant. RC Ordering Information To Order: Select the part number and add the desired coil voltage rating (e.g., G6K-2F-DC5). Terminal Contact form Model Non-latching Non-latching Single coil latching 2.54 mm spacing 3.2 mm coil-contact 3.2 mm coil-contact terminal spacing terminal spacing Gullwing DPDT G6K-2F G6K-2F-Y G6KU-2F-Y Inside L G6K-2G G6K-2G-Y G6KU-2G-Y PCB through-hole G6K-2P G6K-2P-Y G6KU-2P-Y When ordering tape packing (surface mount versions), add -TR to the model number (e.g., G6K-2G-TR-DC5). TR is not part of the relay model number and will not be marked on the relay. -Y models offer an impulse withstand voltage of 2,500 V for2x10s (conforms to Telcordia specifications). When ordering tape packing, minimum order unit is 2 reels (900 pcsx2= 1,800 pcs per box). When ordering tube packing, the minimum order unit is 10 tubes. (50 pcs x 10 tubes = 500 pcs per box). Specifications Contact Data Load Resistive load (cos=1) Rated load 0.3 A at 125 VAC 1Aat30VDC Contact type Bifurcated crossbar Contact material Ag (Au-alloy contact) Rated carry current 2A Max. switching voltage 125 VAC, 60 VDC Max. switching current 1A Max. switching capacity 37.5 VA, 30W Min. permissible load (See note) 10 A at 10 mVDC Note: This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 50 . This value may vary depending on the switching frequency and operating environment. Always double-check relay suitability under actual operating conditions. Low Signal Relay G6K 1 Coil Data G6K- 2.5 mm coil-contact terminal spacing, standard, non-latching (G6K-2F, G6K-2G, G6K-2P) G6K- 3.2 mm coil-contact terminal spacing, non-latching (G6K-2F-Y, G6K-2G-Y, G6K-2P-Y) Rated voltage Rated current Coil resistance Pick-up voltage Dropout voltage Maximum voltage Powerconsumption (VDC) (mA) () (mW) % of rated value 3 33.0 91 80% max. 10% min. 150% max. Approx. 100 4.5 23.2 194 5 21.1 237 6 17.6 341 9 11.3 795 12 9.1 1,315 24 4.6 5,220 G6KU- 3.2 mm spacing, single coil latching (G6KU-2F-Y, G6KU-2G-Y, G6KU-2P-Y) Rated voltage Rated current Coil resistance Set-up voltage Reset voltage Maximum voltage Powerconsumption (VDC) (mA) () (mW) % of rated value 3 33.0 91 75% max. 75% max. 150% max. Approx. 100 4.5 23.2 194 5 21.1 237 6 17.6 341 9 11.3 795 12 9.1 1,315 24 4.6 5,220 Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. 2. The operating characteristics are measured at a coil temperature of 23C unless otherwise specified. 3. Pick-up voltage will vary with temperature 4. The maximum voltage is the highest voltage that can be imposed on the relay coil instantaneously. Characteristics Contact resistance (See note 1) 100 m max. Operate (set) time (See note 2) 3 ms max. (Approx. 1.4 ms - standard. Approx. 1.2 ms - latching) Release (set) time (See note 2) 3 ms max. (Approx. 1.3 ms - standard. Approx. 1.2 ms - latching) Insulation resistance (See note 3) 1,000 M min. (at 500 VDC) Dielectric strength 1,500 VAC, 50/60 Hz for 1 minute between coil contacts 1,000 VAC, 50/60 Hz for 1 minute between contacts of different polarity 750 VAC, 50/60 Hz for 1 minute between contacts of the same polarity Surge withstand voltage -Y versions 2,500 V, (2 x 10 s) between coil and contacts. 1,500 V, (10 x 160 s) between coil and contacts / contacts of different and same polarity. (Conforms to Telcordia and FCC Part 68 specifications) Standard versions 1,500 V, (10 x 160 s) between coil and contacts / contacts of different and same polarity. (Conforms to FCC Part 68) 2 Vibration Mechanical durability 10 to 55 Hz 5.0 mm double amplitude and 50 to 500 Hz, 300 m/s 2 Malfunction durability 10 to 55 Hz 3.3 mm double amplitude and 50 to 500 Hz, 300 m/s 2 Shock Mechanical durability 1,000 m/s (approx. 100G) 2 Malfunction durability 750 m/s (approx. 75G) Ambient operating temperature -40Cto70C with no icing or condensation Ambient operating humidity 5 to 85% RH Service life Mechanical 50,000,000 operations min. (at 36,000 operations per hour) Electrical 100,000 operations min. at rated load (at 1,800 operations per hour) Weight Approx. 0.7 g Note: 1. The contact resistance was measured with 10 mA at 1 VDC with a voltage-drop method. 2. Values in parentheses are typical values unless otherwise stated. 3. The insulation resistance was measured with a 500-VDC megohmmeter applied to the same parts as those for checking the dielectric strength. 4. Data shown are of initial value. 5. The minimum set/reset signal width is 10 ms, for latching coil versions. 2 Low Signal Relay G6K