G6K Surface Mounting Relay Surface Mounting Relay with the Worlds Smallest Mounting Area and a Height of Only 5.2 mm Subminiature model as small as 5.2 (H) 6.5 (W) 10 (L) mm is ideal for high-density mounting. Low profile of 5.2 mm improves mounting efficiency. Light weight of 0.7 g contributes to higher speed mounting. Consumes approximately 70% the power of a conventional OMRON model and operates at a current that is as low as 100 mW. Surface mounting terminal models incorporate a unique terminal structure with high infrared irradiation efficiency which allows the terminal temperature to rise easily when mounting the IRS, thus ensuring excellent soldering. Ensures a dielectric strength of 1,500 VAC and conforms to FCC Part 68 (i.e., withstanding an impulse withstand voltage of 1,500 V for 10 160 s). New-Y models offer an impulse withstand voltage of 2,500 V for 2 10 s (conforms to Telcordia specifications) by optimizing the distance between coil and contacts. Standard model conforms to UL/CSA standards. RoHS Compliant G 6 Model Number Legend Application Examples K Telecommunication equipment G6K - - Office automation machines 123 4 Audio-visual products 1. Relay function 2. Number of contact None : Single-side stable model poles/Contact form U : Single-winding latching model 2: 2-pole/DPDT (2c) 3. Terminal Shape F : Outside-L surface mounting terminals G : Inside-L surface mounting terminals P : PCB terminals 4. Approved standards None : UL, CSA Does not conform to Telcordia specifications Y : UL, CSA Conforms to Telcordia specifications: 2,500 V for 2 10 s Ordering Information Surface Mounting Terminal Standard Models (UL, CSA certified) PCB Terminal Standard Models (UL, CSA certified) Relay Enclosure Contact Rated coil Minimum Relay Enclosure Contact Rated coil Minimum Model Model Function rating form voltage packing unit Function rating form voltage packing unit 3 VDC 3 VDC 4.5 VDC 4.5 VDC G6K-2F 5 VDC G6K-2P 5 VDC 12 VDC 12 VDC 24 VDC Single-side Fully DPDT 24 VDC 3 VDC stable sealed (2c) 3 VDC Highly 4.5 VDC Highly 4.5 VDC 50 insulated 5 VDC insulated 5 VDC pcs/tube G6K-2F-Y 12 VDC G6K-2P-Y 12 VDC Single-side Fully DPDT 24 VDC 24 VDC stable sealed (2c) 3 VDC 3 VDC 4.5 VDC Highly 4.5 VDC Single-winding Fully DPDT G6K-2G 5 VDC insulated 5 VDC latching sealed (2c) 50 12 VDC G6KU-2P-Y 12 VDC 24 VDC pcs/tube 24 VDC 3 VDC (900 Note 1. When ordering, add the rated coil voltage to the model number. Highly 4.5 VDC pcs/reel) Example: G6K-2F 3 VDC insulated 5 VDC Rated coil voltage G6K-2G-Y 12 VDC Note 2. When ordering tape packing, add -T to the model number. 24 VDC Be sure since -T is not part of the relay model number, it is not marked 3 VDC on the relay case. Highly 4.5 VDC insulated 5 VDC G6KU-2F-Y 12 VDC Single-winding Fully DPDT 24 VDC latching sealed (2c) 3 VDC Highly 4.5 VDC insulated 5 VDC G6KU-2G-Y 12 VDC 24 VDC 1G6K Surface Mounting Relay Ratings Coil: Single-side Stable Models Contacts Must operate Must release Max. voltage Item Load Resistive load Item Rated Coil Power voltage (V) voltage (V) (V) current resistance consumption Contact type Bifurcated crossbar Rated voltage (mA) () (mW) % of rated voltage Contact material Ag (Au-Alloy contact) 3 VDC 33.0 91 0.3 A at 125 VAC, Rated load 4.5 VDC 23.2 194 1 A at 30 VDC Approx. 5 VDC 21.1 237 80% max. 10% min. 150% Rated carry current 1 A 100 12 VDC 9.1 1,315 Max. switching voltage 125 VAC, 60 VDC 24 VDC 4.6 5,220 Max. switching current 1 A Note 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. Note 2. The operating characteristics are measured at a coil temperature of 23C. Note 3. The maximum voltage is the highest voltage that can be imposed on the relay coil instantaneously. Coil: Single-winding Latching Models (G6KU-2F-Y, G6KU-2G-Y, G6KU-2P-Y) Must operate Must release Max. voltage Item Rated Coil Power voltage (V) voltage (V) (V) current resistance consumption Rated voltage (mA) () % of rated voltage (mW) 3 VDC 33.0 91 4.5 VDC 23.2 194 Approx. 5 VDC 21.1 237 75% max. 75% max. 150% 100 12 VDC 9.1 1,315 24 VDC 4.6 5,220 G 6 Note 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance K of 10%. Note 2. The operating characteristics are measured at a coil temperature of 23C. Note 3. The maximum voltage is the highest voltage that can be imposed on the relay coil instantaneously. Characteristics Relay Function Single-side stable models Single-winding latching models Item G6K-2F, G6K-2G, G6K-2P G6K-2F-Y, G6K-2G-Y, G6K-2P-Y G6KU-2F-Y, G6KU-2G-Y, G6KU-2P-Y Contact resistance *1 100 m max. Operating (set) time 3 ms max. Release (reset) time 3 ms max. Minimum set/reset signal width 10 ms Insulation resistance *2 1,000 M min. (at 500 VDC) Between coil and 1,500 VAC, 50/60 Hz for 1 min contacts Dielectric Between contacts of 1,000 VAC, 50/60 Hz for 1 min strength different polarity Between contacts of 750 VAC, 50/60 Hz for 1 min the same polarity Between coil and 1,500 V (10 160 s) 2,500 V (2 10 s), 1,500 V (10 160 s) contacts Impulse Between contacts of withstand different polarity voltage 1,500 V (10 160 s) Between contacts of the same polarity 2 Destruction 10-55-10 Hz, 2.5 mm single amplitude (5 mm double amplitude) and 55 to 500 Hz, 300 m/s Vibration resistance 2 Malfunction 10-55-10 Hz, 1.65 mm single amplitude (3.3 mm double amplitude) and 55 to 500 Hz, 200 m/s 2 Destruction 1,000 m/s Shock resistance 2 Malfunction 750 m/s Mechanical 50,000,000 operations min. (at 36,000 operations/hour) Durability Electrical 100,000 operations min. (with a rated load at 1,800 operations/hour) Failure rate (P level) *3 10 A at 10 mVDC Ambient operating temperature -40 to 70C (with no icing or condensation) Ambient operating humidity 5% to 85% Weight Approx. 0.7 g Note: The above values are initial values. *1. The contact resistance was measured with 10 mA at 1 *3. This value was measured at a switching frequency of 120 VDC with a voltage-drop method. operations/min and the criterion of contact resistance is *2. The insulation resistance was measured with a 500 VDC 50 . This value may vary depending on the switching megohmmeter applied to the same parts as those used for frequency and operating environment. Always checking the dielectric strength. double-check relay suitability under actual operating conditions. 2