- - - G6K-2F-RF-V Surface-mounting High-frequency Relay 8-GHz Band Miniature DPDT High Frequency Relay for High-speed Differential Transmission Signal Switching High-frequency characteristics (insertion loss 3 dB or less at 8 GHz) Miniaturized to 11.7 7.9 7.1 mm (L W H). Rated power consumption of 100 mW with high sensitivity RoHS Compliant Application Examples Model Number Legend Semiconductor test equipment G6K-2F-RF-V Test&measurement equipment Communication equipment 12 3 4 1. Number of poles/ 3. Special Function 1 Contact Form RF: High-frequency compatible Standard type specifications 2: 2-pole/ DPDT (2c) G 4. Special Function 2 6 Contact type: Bifurcated crossbar 2. Terminal Shape V: 8-GHz band K Ag (Surface Au alloy) F: Outside-L surface mounting High-speed differential trans- 2 terminals mission compatible type F R Note. We have a lineup of G6K (U)-2F(P)-RF(-S,-T) products for 1-GHz/3-GHz band high-frequency signal applications. F V Ordering Information Relay Function Enclosure rating Contact form Model Rated coil voltage Minimum packing unit Single-side stable Fully sealed DPDT (2c) G6K-2F-RF-V 3, 4.5, 5, 12 VDC 40 pcs/tube Note 1. When ordering, add the rated coil voltage to the model number. Example: G6K-2F-RF-V DC5 Rated coil voltage However, the notation of the coil voltage on the product case as well as on the packing will be marked as VDC. Ratings Contacts High-frequency Characteristics *1 Item Load Resistive load Item Frequency 8GHz 125 VAC, 0.3 A Insertion loss 3 dB max. 30 VDC, 1 A Differential Rated load 10 VDC, 10 mA transmission Isolation 15 dB min. 8 GHz, 1 W * characteristics Return loss (V.SWR) 5 dB min. (3.57 max.) Rated carry current 1 A Insertion loss 4 dB max. Max. switching voltage 125 VAC or 60 VDC Max. switching current 1A Between contacts of 15 dB min. Single-ended the same polarity * This value is for a V.SWR of 1.2 max. at the load. characteristics Isolation Between contacts of (reference value) 15 dB min. different polarity Return loss (V.SWR) 5 dB min. (3.57 max.) Maximum carry power 1 W *2 Maximum switching power 1 W *2 Note 1. The impedance of the measurement system is 50 . (Differential im- pedance is 100 .) Note 2. The above values are initial values. *1. Contact your OMRON representative if the Relay will be used in an application that requires high repeatability in high-frequency characteristics. *2. These values are for a V.SWR of 1.2 max. at the load. 1- - - G6K-2F-RF-V Surface-mounting High-frequency Relay Coil: Single Must operate voltage Must release voltage Maximum voltage Item Rated current Coil resistance Power consumption (V) (V) (V) (mA) () (mW) Rated voltage % of rated voltage 3 VDC 33.0 91 4.5 VDC 23.2 194 80% max. 10% min. 150% Approx. 100 5 VDC 21.1 237 12 VDC 9.1 1,315 Note 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. Note 2. The operating characteristics are measured at a coil temperature of 23C. Note 3. The maximum voltage is the highest voltage that can be imposed on the Relay coil instantaneously. Characteristics Contact resistance *1100 m max. Operating time *2 3 ms max. (approx. 1.4 ms) Release time *2 3 ms max. (approx. 0.7 ms) Insulation resistance *3500 M min. (at 500 VDC) Between coil and 350 VAC, 50/60 Hz for 1 min contacts Between contacts of 350 VAC, 50/60 Hz for 1 min Dielectric different polarity strength Between contacts of the 350 VAC, 50/60 Hz for 1 min same polarity Between ground and 350 VAC, 50/60 Hz for 1 min coil/contacts Destruction 10 to 55 to 10 Hz, 2.5 mm single amplitude (5 mm double amplitude) Vibration G resistance Malfunction 10 to 55 to 10 Hz, 1.65 mm single amplitude (3.3 mm double amplitude) 6 2 Destruction 1,000 m/s Shock K 2 resistance Malfunction 750 m/s 2 Mechanical 50,000,000 operations min. (at a switching frequency of 36,000 operations/hour) F Durability 1,000,000 operations min. (10 VDC, 10 mA, at a switching frequency of 1,800 operations/hour) Electrical R 100,000 operations min. (Other rated load, at a switching frequency of 1,800 operations/hour) F Ambient operating temperature -40C to 70C (with no icing or condensation) V Ambient operating humidity 5% to 85% Weight Approx. 1.16 g Note. The above values are initial values. *1. The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method. *2. Values in parentheses are actual values. *3. The insulation resistance was measured with a 500 VDC megohmmeter applied to the same parts as those used for checking the dielectric strength. 2