( )- ( )- (- - ) G6K(U)-2F(P)-RF(-S, -T) Surface-mounting High-frequency Relay Surface-mounting, 1-GHz-Band/ 3-GHz-Band, Miniature, DPDT, High-frequency Relay Superior high-frequency characteristics (at 1 GHz), such as an isolation of 20 dB min. between contacts of the same polarity of 30 dB min. be- tween contacts of different polarity with an insertion loss of 0.2 dB max. Miniaturized to 10.3 6.9 5.4 mm (L W H). Rated power consumption of 100 mW with high sensitivity Single-side stable and single-winding latching models are available. Models with a smaller footprint (G6K(U)-2F-RF-S) are available to help save space. G6K(U)-2F-RF-T models for 3-GHz band join the lineup with a downsized footprint. New PCB terminals models are available. RoHS Compliant Model Number Legend Application Examples Communications equipment G G6K - - - 6 Broadcasting and audio-visual equipment 1234 5 K Test & measurement equipment 1. Relay Function 4. Special Function U None: Single-side stable RF: High-frequency compatible 2 U: Single-winding latching F 5. Terminal Shape 2. Number of poles/ None: Standard P Contact Form S: Small footprint R 2: 2-pole/ DPDT (2c) T: Compatible with 3 GHz F 3. Terminal Shape S , F: Outside-L surface mount- T ing terminals P: PCB terminals Ordering Information Standard Models with Surface-mounting Terminals Standard Specifications Relay Function Enclosure rating Contact form Model Rated coil voltage Minimum packing unit Single-side stable DPDT G6K-2F-RF 3, 4.5, 5, 12, 24 VDC 300 pcs/tray Fully sealed (2c) 300 pcs/reel Single-winding latching G6KU-2F-RF 3, 4.5, 5, 12, 24 VDC Board space-saving model Relay Function Enclosure rating Contact form Model Rated coil voltage Minimum packing unit Single-side stable G6K-2F-RF-S 3, 4.5, 5, 12, 24 VDC DPDT 300 pcs/tray Fully sealed Single-winding latching (2c) G6KU-2F-RF-S 3, 4.5, 5, 12, 24 VDC 300 pcs/reel Compatible with 3 GHz Relay Function Enclosure rating Contact form Model Rated coil voltage Minimum packing unit Single-side stable G6K-2F-RF-T 3, 4.5, 5, 12, 24 VDC DPDT 300 pcs/tray Fully sealed (2c) 300 pcs/reel Single-winding latching G6KU-2F-RF-T 3, 4.5, 5, 12, 24 VDC PCB terminals Relay Function Enclosure rating Contact form Model Rated coil voltage Minimum packing unit Single-side stable Fully sealed DPDT (2c) G6K-2P-RF 3, 4.5, 5, 12, 24 VDC 30 pcs/tube Note 1. When ordering, add the rated coil voltage to the model number. Example: G6K-2F-RF DC3 Rated coil voltage However, the notation of the coil voltage on the product case as well as on the packing will be marked as VDC. Note 2. When ordering Relays in tape packing, add-TR03 to the end of the model number. Example: G6K-2F-RF-TR03 DC3 Relays per reel: 300 pcs for -TR03 Be sure since-T is not part of the relay model number, it is not marked on the relay case. When ordering tape packing, minimum order unit is 1 reel (300 pcs 1 = 300 pcs). Note 3. Surface mounting terminal (SMT) standard models are shipped in moisture-proof package. PCB terminal standard types do not require moisture proof packaging and therefore shipped in non-moisture-proof package. 1( )- ( )- (- - ) G6K(U)-2F(P)-RF(-S, -T) Surface-mounting High-frequency Relay Ratings Coil: Single-side Stable (G6K-2F(P)-RF(-S, -T)) Must operate voltage Must release voltage Maximum voltage Item Rated current Coil resistance Power consumption (V) (V) (V) (mA) ( ) (mW) Rated voltage % of rated voltage 3 VDC 33.0 91 4.5 VDC 23.2 194 5 VDC 21.1 237 80% max. 10% min. 150% Approx. 100 12 VDC 9.1 1,315 24 VDC 4.6 5,220 Coil: Single-winding Latching Models (G6KU-2F-RF(-S, -T)) Must set voltage Must reset voltage Maximum voltage Item Rated current Coil resistance Power consumption (V) (V) (V) (mA) ( ) (mW) Rated voltage % of rated voltage 3 VDC 33.0 91 4.5 VDC 23.2 194 5 VDC 21.1 237 75% max. 75% max. 150% Approx. 100 12 VDC 9.1 1,315 24 VDC 4.6 5,220 Note 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. Note 2. The operating characteristics are measured at a coil temperature of 23C. Note 3. The maximum voltage is the highest voltage that can be imposed on the Relay coil instantaneously. Contacts High-frequency Characteristics *1 Item Load Resistive load Model G6K(U)-2F(P)-RF(-S) G6K(U)-2F-RF-T 125 VAC, 0.3 A Item Frequency 1GHz 1GHz 3GHz G Rated load 30 VDC, 1 A Between 6 1 GHz, 1 W * contacts of K 20 dB min. 20 dB min. 18 dB min. Rated carry current 1 A the same U polarity Max. switching voltage 125 VAC or 60 VDC Isolation Between Max. switching current 1A 2 contacts of F * This value is for a V.SWR of 1.2 max. at the load. 30 dB min. 30 dB min. 25 dB min. different P polarity Insertion loss 0.2 dB max. 0.2 dB max. 0.6 dB max. R V.SWR 1.2 max. 1.2 max. 1.4 max. F Maximum carry power 3W *2 S , Maximum switching power 1W *2 Note 1. The impedance of the measurement system is 50 . T Note 2. The above values are initial values. *1. Contact your OMRON representative if the Relay will be used in an application that requires high repeatability in high-frequency characteristics for the microload region. (Such applications include testing and measurement equipment and ATE applications.) *2. These values are for a V.SWR of 1.2 max. at the load. Characteristics Relay Function Single-side stable models Single-winding latching models Item Model G6K-2F(P)-RF(-S, -T) G6KU-2F-RF(-S, -T) Contact resistance *1 100 m max. Operating (set) time *2 3 ms max. (approx. 1.4 ms) 3 ms max. (approx. 1.2 ms) Release (reset) time *2 3 ms max. (approx. 1.3 ms) 3 ms max. (approx. 1.2 ms) Minimum set/reset pulse time --- 10 ms Insulation resistance *3 1,000 M min. (at 500 VDC) Between coil and 750 VAC, 50/60 Hz for 1 min contacts Between contacts of 750 VAC, 50/60 Hz for 1 min Dielectric different polarity strength Between contacts of the 750 VAC, 50/60 Hz for 1 min same polarity Between ground and 500 VAC, 50/60 Hz for 1 min coil/contacts 2 Destruction 10 to 55 to 10 Hz, 2.5 mm single amplitude (5 mm double amplitude) and 55 to 500 Hz, 300 m/s Vibration 2 resistance Malfunction 10 to 55 to 10 Hz, 1.65 mm single amplitude (3.3 mm double amplitude) and 55 to 500 Hz, 200 m/s 2 Destruction 1,000 m/s Shock 2 resistance Malfunction 750 m/s Mechanical 50,000,000 operations min. (at a switching frequency of 36,000 operations/hour) Durability Electrical 100,000 operations min. (at a switching frequency of 1,800 operations/hour) Ambient operating temperature -40C to 70C (with no icing or condensation) Ambient operating humidity 5% to 85% Weight Approx. 0.95 g Note. The above values are initial values. *1. The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method. *2. Values in parentheses are actual values. *3. The insulation resistance was measured with a 500 VDC megohmmeter applied to the same parts as those used for checking the dielectric strength. 2