Low Signal Relay
G6L
Extremely Thin SPST-NO Flat Relay, One
of the Thinnest Relays in the World
Uses 20% less mounting area and approximately 64% less
volume in comparison with the G5V-1 relay.
Measures just 7.0 (W) x 10.6 (L) x 4.5 (H) mm for surface-
mount or 4.1 (H) for through-hole.
High dielectric strength: 1,000 VAC between coil and con-
tacts and 750 VAC between contacts of the same polarity.
Conforms to FCC Part 68.
UL recognized / CSA certified
RoHS Compliant - Use of lead completely eliminated.
Ordering Information
Contact form Construction Mounting type Model
SPST-NO Fully sealed Through-hole terminal G6L-1P
Surface-mount terminal G6L-1F
.
Note: 1. When ordering, add the rated coil voltage to the model number.
Example: G6L-1P DC12
Rated coil voltage
2. When ordering tape packing (surface mount versions), add-T to the model number.
Example: G6L-1F-TR DC12
Tape packing
Be sure since -T is not part of the relay model number, it is not marked on the relay case.
Model Number Legend:
G6L - 1 - DC
1 2 3 4
3. Packaging 4. Rated Coil Voltage
1. Contact Form 2. Terminal Shape
3, 4.5, 5, 12, 24
1: SPST-NO None: Tube packaging
P: Through-hole
TR: Tape and reel packaging
F: Surface mount
(SMT versions)
Application Examples
Peripherals of MODEM/PC Communications equipment
Telephones Measurement devices
Office automation machines Amusement equipment
Audio-visual products Security equipment
Low Signal Relay G6L 1Specifications
Contact Ratings
Item Resistive load
Contact material Ag (Au-alloy surface)
Contact type Single crossbar
Rated load 0.3Aat125VAC,1Aat24VDC
Carry current 1A
Max. switching voltage 125 VAC, 60 VDC
Max. switching current 1A
Min. permissible load-Plevel (See note) 1mAat5VDC
Note: This value was measured at a switching frequency of 120 operations/min. This value may vary, depending on switching frequency, operating
conditions, expected reliability level of the relay, etc. It is always recommended to double-check relay suitability under actual load conditions.
Coil Ratings
Item Voltage Rating
Rated voltage 3 VDC 4.5 VDC 5 VDC 12 VDC 24 VDC
Rated current 60.0 mA 40.0 mA 36.0 mA 15.0 mA 9.6 mA
Coil resistance 50.0 112.5 139.0 800.0 2,504.0
Pick-up voltage 75% max. of rated voltage
Dropout voltage 10% min. of rated voltage
Maximum voltage 150% of rated voltage 130% of rated
voltage
Power consumption Approx. 180 mW Approx. 230 mW
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%.
2. The operating characteristics are measured at a coil temperature of 23C.
3. The maximum voltage is the highest voltage that can be imposed on the relay coil.
4. The voltage measurements for Pick-up/Dropout are the values obtained for instantaneous changes in the voltage (rectangular wave).
Characteristics
Item G6L-1P, G6L-1F
Contact resistance (See Note 1) 100 m max.
Operate time (See Note 2) 5 ms max. (approx. 1.1 ms)
Release time (See Note 2) 5 ms max. (approx. 0.4 ms)
Insulation resistance (See Note 3) 1,000 M min. (at 500 VDC)
Dielectric strength Coil and contacts 1,000 VAC, 50/60 Hz for 1 min
Contacts of same 750 VAC, 50/60 Hz for 1 min
poles
Surge withstand Coil and contacts 1,500 VAC, 10 160 s
voltage
Vibration Mechanical durability 10 to 55 Hz, 1.65-mm single amplitude (3.3-mm double amplitude)
Malfunction durability 10 to 55 Hz, 1.65-mm single amplitude (3.3-mm double amplitude)
2
Shock Mechanical durability
1,000 m/s
2
Malfunction durability 100 m/s
Service life Mechanical 5,000,000 operations min. (at 36,000 operations/hour)
Electrical 100,000 operations min. (with a rated load at 1,800 operations/hour)
Ambient operating temperature Operating: -40Cto70C (with no icing or condensation)
Ambient operating humidity Operating: 5% to 85% RH
Weight Approx. 0.6 g
Note: 1. The contact resistance was measured with 10 mA at 1 VDC with a fall-of-potential method.
2. Values in parentheses are actual values.
3. The insulation resistance was measured with a 500-VDC megohmmeter applied to the same parts as those used for checking the dielec-
tric strength.
4. The above values are initial values.
2 Low Signal Relay G6L