G6QE PCB Power Relays Miniature and Low Height Single-pole Power Relay with 36A Switching Current High switching current of 36 A 250 VAC and 10,000 operations, 30 A 250 VAC and 100,000 operations in a miniature package Achieved 10-kV impulse withstand voltage (between coil and contacts) Power consumption reduced to 12% compared with rated coil consumption by lowering the applied voltage to the coil after applying nominal voltage for 100 ms relay operation (Reduced to 35% from rated coil voltage) Conforms to cULus, EN and CQC RoHS Compliant Model Number Legend Application Examples Home appliances G G6QE- FA equipment 6 12 3 Q Industrial machinery E 1. Number of Poles 2. Contact Form 3. Enclosure rating 1: 1-pole A: SPST-NO (1a) None: Flux protection Ordering Information Terminal Shape Classification Contact Form Enclosure rating Model Rated coil voltage Minimum packing unit 5 VDC PCB terminals Standard SPST-NO (1a) Flux protection G6QE-1A 12 VDC 50pcs/tray 24 VDC Note. When ordering, add the rated coil voltage to the model number. Example: G6QE-1A DC12 Rated coil voltage However, the notation of the coil voltage on the product case as well as on the packing will be marked as VDC. Ratings Coil Must operate voltage Must release voltage Max. voltage Rated current Coil resistance Power consumption (V) (V) (V) Rated Voltage (mA) () (mW) % of rated voltage 5 VDC 280 17.9 140% Approx. 1400 12 VDC 116.7 102.9 70% max. 5 to 23% (at 23C) Approx. 172 * 24 VDC 58.3 411.4 Note 1. The rated current and resistance are measured at a coil temperature of 23C with a tolerance of 10%. Note 2. The operating characteristics are measured at a coil temperature of 23C. Note 3. The maximum permissible voltage is the maximum value of the fluctuation range for the Relay coil operating power supply and was measured at an ambient temperature of 23C. * Power consumption with Holding Voltage is approx.172 mW (when applying Holding Voltage at 35%). Please confirm the detail in page 3 Coil Voltage Reduction (Holding Voltage). Contacts Contact type Single Contact material Ag Alloy (Cd free) 36 A at 250 VAC (Resistive Load) Rated load 32 A at 250 VAC (Resistive Load) 30 A at 250 VAC (Resistive Load) Rated carry current 36 A Max. switching voltage AC 277 V Max. switching current AC: 36 A 1G6QE PCB Power Relays Characteristics Contact resistance *1 100 m max. Operate time 20 ms max. Release time 10 ms max. Insulation resistance *2 1000 M min. Between coil and 4,500 VAC, 50/60 Hz for 1 min contacts Dielectric strength Between contacts of 2,000 VAC, 50/60 Hz for 1 min the same polarity Between coil and Insulation distance Clearance: 3.2 mm, Creepage: 6.4 mm contacts Impulse withstand Between coil and 10 kV (1.2 x 50 s) voltage contacts 10 to 55 to 10 Hz, 0.75 mm single amplitude Destruction (1.5 mm double amplitude) Vibration resistance 10 to 55 to 10 Hz, 0.75 mm single amplitude Malfunction (1.5 mm double amplitude) 2 Destruction 1,000 m/s Shock resistance 2 Malfunction 200 m/s Mechanical 1,000,000 operations min. (at 18,000 operations/h) Note. The values given above are initial values. 100,000 operations min. (30 A, 250 VAC, resistive load) *1. Measurement conditions: Durability 50,000 operations min. (32 A, 250 VAC, resistive load) Electrical 5 VDC, 1 A, voltage drop method. 10,000 operations min. (36 A, 250 VAC, resistive load) *2. Measurement conditions: (ON for 1 s and OFF for 9 s) The insulation resistance was measured Failure rate (P level) (reference value) *3 100 mA at 5 VDC with a 500 VDC megohmmeter at the same 35% to 80% of rated coil voltage (contact carrying current 32 A, at 85 C) locations as the dielectric strength was Coil holding voltage *4 35% to 50% of rated coil voltage (contact carrying current 36 A, at 85 C) measured. -40C to +60C (when applying Rated Coil Voltage) *3. This value was measured at a switching G -40C to +85C frequency of 120 operations/min. 6 Ambient operating temperature (contact carrying current 32 A, when applying Holding Voltage at 35% to 80%) *4. Power consumption with Holding Voltage is Q (contact carrying current 36 A, when applying Holding Voltage at 35% to 50%) approx.172 mW (when applying Holding E (with no icing or condensation) Voltage at 35%). Please confirm the detail Ambient operating humidity 5% to 85% in page 3 Coil Voltage Reduction (Holding Weight Approx. 17 g Voltage). Actual Load Life (Reference Values) 250 VAC Capacitive load Inrush: 42 A (0-p), Steady: 30A, Break: 2.5 A 150,000 operations min. (Ambient temperature: 23C) Engineering Data Maximum Switching Capacity Durability Ambient Temperature vs. Maximum Coil Voltage G6QE-1A G6QE-1A G6QE-1A 100 1,000 180 500 160 50 AC resistive load 250 VAC, resistive load 36 140 G6QE-1A 32A 120 100 50 100 10 80 Connecting Method: G6QE-1A 36A Mounted 3 Relays 5 10 60 horizontally based on 5 40 EN Standards Installation Interval: 20 50 mm 1 1 0 1 5 10 50 100 250 500 1,000 010 20 30 40 -40 -20 0 20 40 60 80 100 Switching voltage (V) Contact current (A) Ambient temperature (C) Shock Malfunction Ambient Temperature vs. Maximum Operate or Must Release Voltage G6QE-1A G6QE-1A 100 Y Sample: Must Operating voltage 1,000 G6QE-1A DC12V Must Release voltage Energized Number of Relays: 5 pcs 800 80 600 X Z De- 1,000 400 1,000 60 energized 200 40 200 Shock direction 400 1,000 1,000 Conditions: Shock is applied in X, Y, and Z X 20 Z X X 600 directions three times each with and Y without energizing the Relays to check 800 Z 2 0 the number of contact malfunctions. Unit: m/s Z -60 -40 -20 0 20 40 60 80 100 1,000 2 Y Standard: 200 m/s Y Ambient temperature (C) 2 Switching current (A) Must operate and must release voltage (ratio of rated voltage) (%) 3 Number of operations (10 operations) Maximum coil voltage (%)