G6RL PCB Relay Low-profile power relay with maximum switching of 10 A Low profile: 12.3 mm in height Max. switching capacity: 2,500 VA (NO) Dielectric strength: 5 kV Clearance and creepage distance: 10 mm. RoHS Compliant Applications: Boilers, PLCs, I/O ports, timers, and temperature controllers Ordering Information Classification Enclosure rating Contact form Model Standard Flux protection SPST-NO G6RL-1A SPDT G6RL-1 Note: When ordering, add the rated coil voltage to the model number. Examples: G6RL-1A 12 VDC Rated coil voltage Model Number Legend: G6RL- VDC 12 3 1. Number of Poles 3. Rated Coil Voltage 1: 1 pole 3, 5, 6, 12, 24, 48 VDC 2. Contact Form/Contact Construction None: SPDT A: SPST-NO Specifications Coil Ratings Rated voltage 3 VDC 5 VDC 6 VDC 12 VDC 24 VDC 48 VDC Rated current 73.3 mA 44.0 mA 36.7 mA 18.3 mA 9.2 mA 5.0 mA Coil resistance 40.9 113.6 163.6 654.5 2,618 9,600 Must operate voltage 70% max. of rated voltage Must release voltage 10% min. of rated voltage Max. voltage 150% of rated voltage Power consumption Approx. 220 mW Approx. 240 mW Note: 1. The above items are measured at a coil temperature of 23C. 2. The tolerance of the rated current is 10%. 1G6RL G6RL Contact Ratings Load Resistive load (cos = 1) Rated load 8 A at 250 VAC, resistive load 5 A at 24 VDC, resistive load Rated carry current 10 A at 250 VAC 5 A at 30 VDC Max. switching voltage 400 VAC, 300 VDC Max. switching current NO: 10 A, NC: 8 A Max. switching power NO: 2,500 VA, NC: 2,000 VA 150 W Failure rate (reference value) 10 mA at 5 VDC (P Level) 6 Note: P level: 60 = 0.1 10 / operations Characteristics Contact resistance 100 m max. Operate time 10 ms max. Release time 5 ms max. Insulation resistance 1,000 M min. (at 500 VDC) Dielectric strength 5,000 VAC, 50/60 Hz for 1 min between coil and contacts 1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity Impulse withstand voltage 10 kV between coil and contacts (1.2 50 s) Vibration resistance Destruction: 10 to 55 to 10 Hz, 1.5-mm double amplitude Malfunction: 10 to 55 to 10 Hz, 0.825-mm single amplitude (1.65-mm double amplitude) when energized. 10 to 55 to 10 Hz, 0.4-mm single amplitude (0.8-mm double amplitude) when not energized. 2 Shock resistance Destruction: 1,000 m/s 2 2 Malfunction: 200 m/s NO, 50 m/s NC when not energized Endurance (Mechanical) 10,000,000 operations min. (at 18,000 operations/h) Ambient temperature Operating: 40C to 85C (with no icing) Ambient humidity Operating: 5% to 85% Weight Approx. 7.8 g Other data Insulation material group IIIa Rated insulation voltage 250 V Pollution degree32 Rated voltage system 250 V 400 V Over-voltage category III Contact material AgNi Creepage distance 10 mm Clearance distance 10 mm RoHS Compliant Tracking index of relay base PTI 250 Flammability class accord- V-0 ing to UL94 Flammability-flame GWFI (IEC 60695-2-12) 850C GWIT (IEC 60695-2-13) 750C Ball pressure test (IEC 170C 60695-10-2) 2