PCB Relay G6RN Heavy-duty Miniature Relay Incorporates environment-friendly, cadmium-free contacts. Variety of contact forms: SPDT or SPST-NO (continuous current rating: 8 A) Mechanical and electrical characteristics comply with VDE0435. Satisfies VDE0700 requirements with a dielectric strength of 4 kV at a distance of 8 mm. Satisfies C/250 insulation requirements of VDE0110. Tracking resistance: CTI>250 VDE Conforms to class II, part 1 of VDE0106. RC X Ordering Information Classification Enclosure ratings Contact material Contact form SPST-NO SPDT Standard Fully sealed AgNi + gold plating (0.35 ) G6RN-1A G6RN-1 AgNi G6RN-1A-ANI G6RN-1-ANI AgCdO + gold plating (0.35 ) G6RN-1A-ACD G6RN-1-ACD AgCdO G6RN-1A-CDM G6RN-1-CDM AgNi + gold plating (4 ) G6RN-1A-AP4 G6RN-1-AP4 Note: When ordering, add the rated coil voltage to the model number. Example: G6RN-1A 24 VDC Rated coil voltage Model Number Legend G6RN- - VDC 1 2 3 4 1. Number of Poles 3. Contact Material 1: 1 pole None: AgNi + gold plating (0.35 ) 2. Contact Form ANI: AgNi None: SPDT ACD: AgCdO + gold plating (0.35 ) A: SPST-NO CDM: AgCdO AP4: AgNi + gold plating (4 ) 4. Rated Coil Voltage 5, 12, 24, 48 VDC 120G6RN G6RN Specifications Coil Ratings Rated voltage 5 VDC 12 VDC 24 VDC 48 VDC Rated current 44 mA 18.3 mA 9.2 mA 5.2 mA Coil resistance 114 W 655 W 2,620 W 9,210 W Must operate voltage 70% max. of rated voltage Must release voltage 10% min. of rated voltage Max. voltage 110% of rated voltage at max. temperature (at 85C) Power consumption Approx. 220 mW Approx. 250 mW Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. 2. Operating characteristics are measured at a coil temperature of 23C. Contact Ratings Load Resistance load (cos f = 1) Rated load 8 A at 250 VAC: 5 A at 30 VDC Rated carry current 8 A Max. switching voltage 250 VAC 30 VDC, (400 VAC) (see note) Max. switching current AC 8 A DC 5 A Max. switching power 2,000 VA 150 W Failure rate (reference value) 5 VDC 10 mA (for gold plating 0.35 min.) Note: Electrical life expectancy is reduced. Characteristics Operate time Approx. 6 ms Release time Approx. 3 ms Max. operating frequency Mechanical: 36,000 operations/hr Electrical: 360 operations/hr (under rated load) Insulation resistance 1,000 MW min. (at 500 VDC) Dielectric strength 4,000 VAC between coil and contacts 1,000 VAC between contacts Creepage/clearance 8 mm min. between coil and contacts Vibration resistance Malfunction: NO: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude) NC: 10 to 55 to 10 Hz, 0.4-mm single amplitude (0.8-mm double amplitude) 2 Shock resistance Destruction: 1,000 m/s Endurance Mechanical: 10,000,000 operations min. Electrical: Approx. 100,000 operations Ambient temperature Operating: -40C to 85C (with no icing) Ambient humidity Operating: 5% to 85% Weight Approx. 9 g Protection class II according to VDE0106 Part 1 Insulation class C/250, B/380 according to VDE0110 Approved Standards IEC255 (Includes Reinforced Insulation and Spacing Requirements According to IEC65, 335-1, 950, EN60335-1, 60950) Standard Contact form Coil ratings Contact ratings Conditions IEC255-1-00 SPDT 5, 6, 12, 18, 24, 8 A at 250 VAC (cosf = 1) Pollution degree: 3 IEC255-0-20 SPST-NO 36, 48 VDC (see note) Overvoltage category: II Operating range: class 1 Pick-up class: class C Ambient temperature: -40C to 85C Note: VAC according to IEC417. 121