Low Signal Relay G6S Suface Mount DPDT Relay High dielectric withstand voltage of 2,000 VAC between coil and contacts (standard type) 1,500 VAC between contacts of different polarity. Meets FCC Part 68 and Telcordia 2.5 kV surge withstand. European version certified for EN60950/EN41003 Supple- mentary Insulation at 250 V at Pollution Degree 2. Low power consumption of 140 mW (Non-latching) Available in through-hole and SMT terminals. Tape and reel or tube packaging. RoHS Compliant. Ordering Information Standard Version . Model Non-latching Terminal Single coil latching Dual coil latching Standard European Version* Contact form Gull-wing DPDT G6S-2F G6S-2F-Y G6SU-2F G6SK-2F Inside L G6S-2G G6S-2G-Y G6SU-2G G6SK-2G PCB through-hole G6S-2 G6S-2-Y G6SU-2 G6SK-2 * Certified for EN60950/EN41003 Supplementary Insulation at 250 V (pollution degree 2) Notes: 1. When ordering, add the rated coil voltage to the model number. Example: G6S-2F DC12 Rated coil voltage 2. When ordering tape packing (surface mount models), add -T to the model number. Example: G6S-2F-TR DC12 Tape packing -T is not part of the relay model number. Therefore, it is not marked on the relay case. 3. Dual coil latching models are available with a High-sensitivity coil. (140 mW 200 mW for DC24) When ordering High-sensitivity dual coil latching models, add-H to the model number. Example: G6SK-2G-H-TR DC5 High-sensitivity coil Model Number Legend G6S - - - DC 1 2 3 4 5 6 3. Terminal Shape 5. Packaging 1. Relay Function None: Tube packaging None: Non-latching None: Through-hole TR: Tape and reel packaging U: Single coil latching F: Gull-wing surface mount (Surface mount models) K: Dual coil latching G: Inside L surface mount 2. Contact Form 4. Approved Standards 6. Rated Coil Voltage 2: DPDT None: UL/CSA 3, 4.5, 5, 12, 24 VDC Y: EN60950/EN41003 (Standard coil models - 5, 12, 24 VDC ) Low Signal Relay G6S 79Specification Contact Data Load Resistive load (cos = 1) Rated load 0.5 A at 125 VAC 2 A at 30 VDC Contact material Ag (Au clad) Max. carry current 2 A Max. operating voltage 250 VAC, 220 VDC Max. operating current 2 A Max. switching capacity 62.5 VA, 60 W Min. permissible load 10 A, 10 mVDC -6 Note: P level: = 0.1 x 10 /operation 60 This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 50 . This value may vary depending on the operating environment. Always double-check relay suitability under actual operating conditions. Coil Data G6S - Standard Non-latching (G6S-2F, G6S-2G, G6S-2) Pick-up Dropout Maximum Rated Rated Coil voltage voltage voltage voltage current resistance Power consumption (mW) (VDC) (mA) () % of rated voltage 3 46.7 64.3 75% max. 10% min. 200% max. 23C Approx. 140 4.5 31.0 145 5 28.1 178 12 11.7 1,028 24 8.3 2,880 170% max. 23C Approx. 200 G6SU - Standard Single Coil Latching (G6SU-2F, G6SU-2G, G6SU-2) Coil Inductance (H) Set pick-up Reset pick-up Rated Rated Coil Power Maximum volt- (ref. value) voltage voltage voltage current resistance consumption age (VDC) (mA) () (mW) Armature OFF Armature ON % of rated voltage 3 33.3 90 0.108 0.069 75% max. 75% max. 180% max. Approx. 100 23C 4.5 22.2 203 0.27 0.14 5 20.0 250 0.36 0.18 12 8.3 1,440 2.12 1.14 24 6.3 3,840 5.80 3.79 Approx. 150 G6SK - Standard Dual Coil Latching (G6SK-2F, G6SK-2G, G6SK-2) Coil Inductance (H) Set Reset (ref. value) pick-up pick-up Rated Rated Coil Power Maximum voltage voltage voltage current resistance Set Reset consumption voltage (VDC) (mA) () (mW) Armature Armature Armature Armature % of rated voltage OFF ON OFF ON 3 66.6 45 0.045 0.035 0.032 0.045 75% max. 75% max. 170% max. Approx. 200 23C 4.5 44.4 101 0.12 0.074 0.082 0.14 5 40 125 0.14 0.088 0.098 0.16 12 16.7 720 0.60 0.41 0.46 0.54 24 12.5 1,920 1.98 1.23 1.34 2.23 140% max. Approx. 300 23C G6S - European Version, Non-latching (G6S-2F-Y, G6S-2G-Y, G6S-2-Y) Rated Rated Coil Pick-up Dropout Maximum Power consumption (mW) voltage current resistance voltage voltage voltage (VDC) (mA) () % of rated voltage 5 40.0 125 75% max. 10% min. 170% max. 23C Approx. 200 12 16.7 720 24 9.6 2,504 Approx. 230 Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. 2. The operating characteristics are measured at a coil temperature of 23C. 3. Pick-up voltage will vary with temperature. 4. The maximum voltage is the highest voltage that can be imposed on the relay coil. 80 Low Signal Relay G6S