G6S Surface-mounting Relay Compact, Industry-Standard 2-pole relay, designed to switch 2A Signal Loads. Long terminals for ideal for soldering and mounting reliability. (Surface mounting terminal models) Space-saving inside-L terminal. (Surface mounting terminal models) Unique terminal structure, designed to withstand IRS soldering processes. (Surface mounting terminal models) High dielectric strength (2,000 VAC) and impulse withstand voltage between coil and contacts (2,500 V, 2 10 s: Telcordia requirements). Ultra-miniature at 9.4 mm (H) 7.5 mm (W) 15 mm (L). Models available with BSI (EN 60950) supplementary insulation certification. (-Y type) RoHS Compliant Model Number Legend Application Examples Telecommunication equipment G6S - - Measurement devices 123 4 G Office automation machines 1. Relay Function 3. Terminal Shape 6 Audio-visual products. S None : Single-side stable None : PCB terminals Security equipment U : Single-winding latching F : Outside-L surface mounting terminals Building automation equipment K : Double-winding latching G : Inside-L surface mounting terminals Industrial equipment 2. Number of poles/ 4. Approved Standards Contact form Amusement equipment None : UL, CSA 2: 2-pole/DPDT (2c) Home appliances Y : UL, CSA, BSI (EN60950) Ordering Information Surface mounting terminal standard models Packing Tube Packing Tape Packing Rated coil Minimum Rated coil Minimum Minimum ordering unit Enclosure rating Relay Function Contact form Model voltage packing unit Model voltage packing unit (tape packing) 3 VDC 3 VDC 4.5 VDC 4.5 VDC G6S-2F G6S-2F-TR 5 VDC 5 VDC G6S-2G G6S-2G-TR 12 VDC 12 VDC Single-side stable 24 VDC 24 VDC 5 VDC 5 VDC G6S-2F-Y G6S-2F-Y-TR 12 VDC 12 VDC G6S-2G-Y G6S-2G-Y-TR 24 VDC 24 VDC 3 VDC 3 VDC 4.5 VDC 4.5 VDC G6SU-2F G6SU-2F-TR Fully sealed DPDT (2c) 5 VDC 50 pcs/tube 5 VDC 400 pcs/reel 800 pcs/2 reels G6SU-2G G6SU-2G-TR 12 VDC 12 VDC Single-winding latching 24 VDC 24 VDC 5 VDC 5 VDC G6SU-2F-Y G6SU-2F-Y-TR 12 VDC 12 VDC G6SU-2G-Y G6SU-2G-Y-TR 24 VDC 24 VDC 3 VDC 3 VDC 4.5 VDC 4.5 VDC Double-winding G6SK-2F G6SK-2F-TR 5 VDC 5 VDC latching G6SK-2G G6SK-2G-TR 12 VDC 12 VDC 24 VDC 24 VDC Note 1. When ordering, add the rated coil voltage to the model number. Example: G6S-2F DC3 Rated coil voltage However, the notation of the coil voltage on the product case as well as on the packing will be marked as VDC. Note 2.When ordering tape packing, add -T to the model number. Be sure since -T is n ot part of the relay model number, it is not marked on the relay case. Note 3.When ordering tape packing, minimum order unit is 2 reels (400 pcs 2 = 800 pcs). 1G6S Surface-mounting Relay PCB Terminal Standard Models Relay Function Single-side stable Single-winding latching Double-winding latching Minimum Enclosure packing unit rating Contact form Model Rated coil voltage Model Rated coil voltage Model Rated coil voltage 3 VDC 3 VDC 3 VDC 4.5 VDC 4.5 VDC 4.5 VDC G6S-2 5 VDC G6SU-2 5 VDC G6SK-2 5 VDC 12 VDC 12 VDC 12 VDC Fully sealed DPDT (2c) 50 pcs/tube 24 VDC 24 VDC 24 VDC 5 VDC 5 VDC G6S-2-Y 12 VDC G6SU-2-Y 12 VDC 24 VDC 24 VDC Note: When ordering, add the rated coil voltage to the model number. Example: G6S-2 3 VDC Rated coil voltage However, the notation of the coil voltage on the product case as well as on the packing will be marked as VDC. Ratings Single-side Stable Model Contacts Item Rated Coil Must Power Item Load Resistive load Must release Max. current resistance operate consumption voltage (V) voltage (V) Contact type Bifurcated crossbar Model Rated voltage (mA) ( ) voltage (V) (mW) Contact material Ag (Au-Alloy) 346.7 64.3 0.5 A at 125 VAC 4.5 31 145 200% Rated load Approx. 140 G6S-2 2 A at 30 VDC (at 23C) 5 28.1 178 G G6S-2F DC 75% max. 10% min. Rated carry 12 11.7 1,028 6 2 A G6S-2G current S 170% 24 8.3 2,880 Approx. 200 Max. switching (at 23C) 250 VAC, 220 VDC voltage 540 125 G6S-2-Y Approx. 200 170% Max. switching G6S-2F-Y DC 12 16.7 720 75% max. 10% min. 2 A (at 23C) current G6S-2G-Y 24 9.6 2,504 Approx. 230 Note 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. 2.Operating characteristics are measured at a coil temperature of 23C. 3.The maximum voltage is the highest voltage that can be imposed on the relay coil. Single-winding Latching Model Item Rated Coil Must Power Must release Max. current resistance operate consumption voltage (V) voltage (V) Model Rated voltage (mA) ( ) voltage (V) (mW) 333.3 90 4.5 22.2 203 G6SU-2 Approx. 100 180% G6SU-2F DC 520 250 75% max. 75% max. (at 23C) G6SU-2G 12 8.3 1,440 24 6.3 3,840 Approx. 150 5 28.1 178 G6SU-2-Y 200% G6SU-2F-Y DC 12 11.7 1,028 75% max. 75% max. Approx. 140 (at 23C) G6SU-2G-Y 24 5.8 4,114 Note 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. 2.Operating characteristics are measured at a coil temperature of 23C. 3.The maximum voltage is the highest voltage that can be imposed on the relay coil. Double-winding Latching Model Item Rated Coil Must Power Must release Max. current resistance operate consumption voltage (V) voltage (V) Model Rated voltage (mA) ( ) voltage (V) (mW) 366.6 45 4.5 44.4 101 170% Approx. 200 G6SK-2 (at 23C) 540 125 G6SK-2F DC 75% max. 75% max. 12 16.7 720 G6SK-2G 140% 24 12.5 1,920 Approx. 300 (at 23C) Note 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. 2.Operating characteristics are measured at a coil temperature of 23C. 3.The maximum voltage is the highest voltage that can be imposed on the relay coil. 2