Omron 08 Cat 1-302 5/10/07 15:39 Page 230 TSurface-Mounting Signal Relay G6Kext TSurface-Mounting Signal Relay G6Sext Surface-Mounting DPDT Relay Precautions ROHS compliant. CORRECT USE Maximum Allowable Voltage Long terminals ideal for soldering and The maximum allowable voltage of the coil can be obtained from Handling mounting reliability. the coil temperature increase and the heat-resisting temperature Leave the Relay unpacked until mounting it. of coil insulating sheath material. (Exceeding the heat-resisting Soldering Space-saving inside-L terminal. temperature may result in burning or short-circuiting.) The Solder: JIS Z3282, H63A maximum allowable voltage also involves important restrictions High dielectric strength between coil and Soldering temperature: Approx. 250C (260C if the DWS method which include the following: contacts (2,000 VAC), and between contacts is used) Must not cause thermal changes in or deterioration of the Soldering time: Approx. 5 s max. (approx. 2 s for the first time and insulating material. of different polarity (1,500 VAC). approx. 3 s for the second time if the DWS method is used) Must not cause damage to other control devices. High impulse withstand voltages between coil Be sure to make a molten solder level adjustment so that the Must not cause any harmful effect on people. and contacts, and between contacts of solder will not overflow on the PCB. Must not cause fire. different polarity (2,500 V, 2 10 s: Bellcore Claw Securing Force During Automatic Mounting Therefore, be sure to use the maximum allowable voltage beyond During automatic insertion of Relays, make sure to set the requirements). the value specified in the catalog. securing force of each claw to the following so that the Relays As a rule, the rated voltage must be applied to the coil. A voltage Ultra-miniature at 15 x 7.5 x 9.4 mm Low power consumption (140 mW). characteristics are maintained. exceeding the rated value, however, can be applied to the coil (L x W x H). provided that the voltage is less than the maximum allowable Bifurcated crossbar contact (Au-clad) and voltage. It must be noted that continuous voltage application to Through-hole terminal is available Fully sealed construction for high reliability. the coil will cause a coil temperature increase thus affecting characteristics such as electrical life and resulting in the Applicable to IRS. EN60950 Supplementary Insulation-certified deterioration of coil insulation. type is available. High sealability after IRS. Coating The Relay mounted on the PCB may be coated or washed but do Direction A: 1.96 N not apply silicone coating or detergent containing silicone, Direction B: 4.90 N Direction C: 1.96 N otherwise the silicone coating or detergent may remain on the Environmental Conditions During Operation, Storage, and surface of the Relay. Ordering Information Transportation PCB Mounting Protect the Relay from direct sunlight and keep the Relay under If two or more Relays are closely mounted with the long sides of Classification Single-side Single-winding Double-winding Single-side stable normal temperature, humidity, and pressure. the Relays facing each other and soldering is performed with Stable latching latching EN60950/EN41003 infrared radiation, the solder may not be properly exposed to the If the Relay is stored for a long time in an adverse environment DPDT Fully Through-hole terminal G6S-2 G6SU-2 G6SK-2 G6S-2-Y with high temperature, high humidity, organic gases, or sulphide infrared rays. Be sure to keep the proper distance between sealed gases, sulphide or oxide films will form on the contact surfaces. adjacent Relays as shown below. Surface mounting Inside-L G6S-2G G6SU-2G G6SK-2G G6S-2G-Y These films may result in unstable contact, contact problems, or terminal Outside-L G6S-2F G6SU-2F G6SK-2F G6S-2F-Y G6K-2G functional problems. Therefore, operate, store, or transport the product under specified environmental conditions. Note: 1. When ordering, add the rated coil voltage to the model number. Latching Relay Mounting Example: G6S-2F 12 VDC Make sure that the vibration or shock that is generated from other Rated coil voltage 2 mm min. devices, such as relays in operation, on the same panel and 2. When ordering tape packing, add -T to the model number. imposed on the Latching Relay does not exceed the rated value, Example: G6S-2F-TR 12 VDC otherwise the Latching Relay that has been set may be reset or G6K-2F Tape packing vice versa. The Latching Relay is reset before shipping. If Be sure since -T is not part of the relay model number, it is not marked on the relay case. excessive vibration or shock is imposed, however, the Latching Relay may be set accidentally. Be sure to apply a reset signal before use. Model Number Legend 2.7 mm min. Two or more Relays may be closely mounted with the short sides of the Relays facing each other. 1. Relay Function 4. Approved Standards None: Single-side stable None: UL/CSA U: Single-winding latching Y: EN60950 K: Double-winding latching 5. Rated Coil Voltage 2. Contact Form 4.5, 5, 12, 24 VDC 2: DPDT 3. Terminal Shape None: Through-hole terminal G: Inside-L surface mounting terminal F: Outside-L surface mounting terminal CAT. No. K106-E2-04A-X 230 231 Signal RelaysOmron 08 Cat 1-302 5/10/07 15:39 Page 232 Surface-Mounting Signal Relay G6SText TSurface-Mounting Signal Relay G6Sext Single-side Stable EN60950 Approved Type (G6S-2-Y, G6S-2F-Y, G6S-2G-Y) Specifications Rated voltage 5 VDC 12 VDC 24 VDC Coil Ratings Rated current 40 mA 16.7 mA 9.6 mA Single-side Stable Type (G6S-2, G6S-2F, G6S-2G) Coil resistance 125 720 2,504 Rated voltage 4.5 VDC 5 VDC 12 VDC 24 VDC Must operate voltage 75% max. of rated voltage Rated current 31.0 mA 28.1 mA 11.7 mA 8.3 mA Must release voltage 10% min. of rated voltage Coil resistance 145 178 1,028 2,880 Max. voltage 170% of rated voltage at 23C 170% of rated voltage at 23C Must operate voltage 75% max. of rated voltage Power consumption Approx. 200 mW Approx. 230 mW Must release voltage 10% min. of rated voltage Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. Max. voltage 200% of rated voltage at 23C 170% of rated 2. Operating characteristics are measured at a coil temperature of 23C. voltage at 23C 3. The maximum voltage is the highest voltage that can be imposed on the relay coil. Power consumption Approx. 140 mW Approx. 200 mW Contact Ratings Single-winding Latching Type (G6SU-2, G6SU-2F, G6SU-2G) Load Resistive load (cos = 1) Rated voltage 4.5 VDC 5 VDC 12 VDC 24 VDC Rated Load 0.5 A at 125 VAC 2 A at 30 VDC Rated current 22.2 mA 20 mA 8.3 mA 6.3 mA Contact material Ag (Au-alloy) Coil resistance 203 250 1,440 3,840 Rated Carry Current 2 A Coil inductance Armature OFF 0.27 0.36 2.12 5.80 Max. switching voltage 250 VAC, 220 VDC (H) (ref. value) Armature ON 0.14 0.18 1.14 3.79 Max. switching current 2 A Must set voltage 75% max. of rated voltage Max. switching power 62.5 VA, 60 W Must reset voltage 75% min. of rated voltage Failure rate (reference value) 10 A at 10 mVDC (see note) Max. voltage 180% of rated voltage at 23C -6 Power consumption Approx. 100 mW Approx. 150 mW Note: P level: = 0.1 x 10 /operation. This value was measured at a switching frequency of 120 operations/min and the criterion of 60 contact resistance is 50. This value may vary depending on the operating environment. Always double-check relay suitability under actual operating conditions. Double-winding Latching Type (G6SK-2, G6SK-2F, G6SK-2G) Rated voltage 4.5 VDC 5 VDC 12 VDC 24 VDC Rated current 44.4 mA 40 mA 16.7 mA 12.5 mA Coil resistance 101 125 720 1,920 Coil ind- Set Armature OFF 0.12 0.14 0.60 1.98 uctance Armature ON 0.074 0.088 0.41 1.23 (H) (ref. value) Reset Armature OFF 0.082 0.098 0.46 1.34 Armature ON 0.14 0.16 0.54 2.23 Must set voltage 75% max. of rated voltage Must reset voltage 75% min. of rated voltage Max. voltage 170% of rated voltage at 23C 140% of rated voltage at 23C Power consumption Approx. 200 mW Approx. 300 mW Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. 2. Operating characteristics are measured at a coil temperature of 23C. 3. The maximum voltage is the highest voltage that can be imposed on the relay coil. 232 233 Signal Relays