P15E-EN-03A+SmartSlice+Datasheet.fm Seite 1 Mittwoch, 30. April 2008 10:34 10 SmartSlice The smartest modular I/O system OMRON s SmartSlice I/O system is compact, intelligent and easy. When used with OMRON s CS1/CJ1 DeviceNet or CompoNet master units, no configuration tool is required. By using built-in functions such as pre-scaling, totalising, differentiation and alarming in analog I/O units, PLC pro- gramming can be minimised. Preventive maintenance data collected by all I/O units can be accessed using CX-Integra- tor or NS-series Smart Active Parts. Most compact in the market (84 mm high) Easy set-up, backup and restore functions Diagnostics and preventive maintenance data at I/O level Detachable terminal blocks allow hot-swapping without re-wiring 3-wire I/O connection with push-in technology, no screw- driver required System Configuration CX-One for setup, CS1/CJ1 PLC series or monitoring and operation Trajexia Motion Controller (ML-II only) of all OMRON Devices PLC Slave Communication Unit GRT1-TBR Right Turnback Unit GCN2-100 Turnback Cable (1 m) Max. 2 per station. I/O Units GRT1-END End Unit GRT1-TBL Left Turnback Unit Up to 64 I/O Units can be connected to a Communication Unit. SmartSlice 1P15E-EN-03A+SmartSlice+Datasheet.fm Seite 2 Mittwoch, 30. April 2008 10:34 10 Specifications General Specifications Common SmartSlice Specifications Unit power supply voltage 24 VDC (20.4 to 26.4 VDC) I/O power supply voltage 24 VDC (20.4 to 26.4 VDC) I/O connection Screwless push-in technology Noise immunity Conforms to IEC61000-4-4, 2.0 kV (power supply line) 2 Vibration resistance 10 to 60 Hz: 0.7 mm double amplitude 60 to 150 Hz: 50 m/s 2 Shock resistance 150 m/s , 3 times in each direction Dielectric strength 500 VAC (between isolated circuits) Insulation resistance 20 M min. (between isolated circuits) Ambient operating temperature -10 to 55C (with no icing or condensation) Ambient operating humidity 25% to 85% Operating environment No corrosive gases Ambient storage temperature -25 to 65C (with no icing or condensation) Mounting 35 mm DIN rail Communication Units Model name GRT1-PNT GRT1-PRT GRT1-DRT GRT1-CRT GRT1-ML2 Network Specification PROFINET-IO PROFIBUS-DPV1 DeviceNet CompoNet MECHATROLINK-II for Trajexia Network connector 2 x RJ45, built-in switch 9-pin D-Sub Open-style DeviceNet 4-pin CompoNet 2 x ML-II with support for MRP re- connector, dundancy. dual screwless push-in dual connections. Network interface power supply Internal External, Internal 11 to 25 VDC, 22 mA Number of I/O points 1,024 inputs and outputs max. (128 bytes each) 32 bytes input + 32 bytes 1,024 inputs and outputs output max. max. (128 bytes each) Number of connectable Units 64 SmartSlice I/O Units max. I/O power supply 24 VDC, 4 A max. Status flags 1 word for Communications Unit status flags Parameter backup and restore up to 2 KB of data per I/O Unit. 2 Control System