Solid-state Timer H3RN Ultra-slim Timer for G2R Relay Socket Pin configuration compatible with G2R Relay and mounts to the P2R/P2RF Socket. Standard multiple time ranges and multiple operating modes. Conforms to VDE 0435/P2021 and approved by UL and CSA. Conforms to EMC standards. RC Ordering Information Supply voltage Time-limit contact Short-time range model Long-time range model (0.1sto10min) (0.1minto10h) 24 VAC SPDT H3RN-1 H3RN-11 12,12 2424 VVDDCC DPST-NO H3RN-2 H3RN-21 Note: Specify both the model number and supply voltage when ordering. Example: H3RN-1 24 VAC Supply voltage Model Number Legend: H3RN-jj 12 1. Output 2. Time Range 1: SPDT None: Short-time range (0.1 s to 10 min) 2: DPST-NO 1: Long-time range (0.1 min to 10 hrs) Accessories (Order Separately) Connecting Socket Timer Track mounting/Front connecting Back connecting socket socket H3RN-1/-11 P2RF-05-E P2R-057P H3RN-2/-21 P2RF-08-E P2R-087P 4H3RN H3RN Specifications Ratings Item H3RN-1/-2 H3RN-11/-21 Time ranges 0.1 s to 10 min (1 s, 10 s, 1 min, or 10 min 0.1 min to 10 h (1 min, 10 min, 1 h, or 10 hrs max. selectable) max. selectable) Rated supply voltage 24 VAC 12, 24 VDC Pin type Plug-in Operating mode ON-delay, interval, flicker OFF-start, or flicker-ON start selectable by DIP switch Operating voltage range 85% to 110% of rated supply voltage (12 VDC: 90% to 110% of rated supply voltage) (see note) Power consumption 24 VAC: Relay ON: approx. 0.8 VA (at 24 VAC, 60 Hz) Relay OFF: 0.5 VA (at 24 VAC, 60 Hz) 12 VDC: Relay ON: approx. 0.4 W (at 12 VDC) Relay OFF: 0.1 W (at 12 VDC) 24 VDC: Relay ON: approx. 0.5 W (at 24 VDC) Relay OFF: 0.2 W (at 24 VDC) Control outputs 3 A at 250 VAC, resistive load (cos =1)(G6B-2j14P-FD-US used) The minimum applicable load is 10 mA at 5 VDC (P reference value). Note: When using the H3RN in any place where the ambient temperature is more than 50 C, supply 90% to 110% of the rated voltages (12 VDC: 95% to 110% of the rated voltage). Characteristics Item H3RN-1/-2 H3RN-11/-21 Accuracy of operating time 1% FS max. (1 s range: 1% 10 ms max.) Setting error 15% 50 ms FS max. Reset time Min. power-opening time: 12, 24 VDC: 0.1 s max. (including halfway reset) 24 VAC: 0.5 s max. (including halfway reset) Influence of voltage 2% FS max. Influence of temperature 2% FS max. Insulation resistance 100 M min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min (between operating circuit and control output, or contacts of different poles) 1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts) Vibration resistance Destruction: 10 to 55 Hz, 0.75-mm single amplitude Malfunction: 10 to 55 Hz, 0.5-mm single amplitude 2 Shock resistance Destruction: 300 m/s (approx. 30G) 2 Malfunction: 100 m/s (approx. 10G) Ambient temperature Operating: --10 Cto55 C (with no icing) Storage: --25 Cto65 C (with no icing) Ambient humidity Operating: 35% to 85% Life expectancy Mechanical: 10,000,000 operations min. (under no load at 1,800 operations/h) Electrical: 100,000 operations min. (3 A at 250 VAC, resistive load at 1,800 operations/h) Impulse withstand voltage Between power terminals: 1 kV Noise immunity 1.5 kV, square-wave noise by noise simulator (pulse width: 100 ns/1 %s, 1-ns rise) Static immunity Destruction: 8 kV Malfunction: 4 kV Enclosure rating IP20 Weight Approx. 18 g EMC Emission Enclosure: EN55011 Group 1 class A Emission AC Mains: EN55011 Group 1 class A Immunity ESD: EN61000-4-2: 4 kV contact discharge (level 2) 8 kV air discharge (level 3) Immunity RF-interference: ENV50140: 10 V/m (amplitude modulated, 80 MHz to 1GHz)(level 3) 10 V/m (pulse modulated, 900 MHz) Immunity Conducted Disturbance: ENV50141: 10 V (0.15 to 80 MHz) (level 3) Immunity Burst: EN61000-4-4: 2 kV power-line (level 3) 2 kV I/O signal-line (level 4) Approved standards UL508, CSA22.2 No. 14 Conforms to VDE 0435/P2021 (for built-in use) Conforms to EN50081-2, EN50082-2 5