Solid-state Timer H3Y Miniature Timer Compatible with the MY Relay Large transparent time-setting knob facilitates time setting. Flat-blade and Phillips screwdrivers can also be used for time setting. Approved by UL and CSA. Pin configuration compatible with MY Power Relay. LED indication for power and output statuses. Conforms to EMC standards. High repeat accuracy. RC Ordering Information Operation/resettingOpe a o / ese g Time-limitec contactoac Time rangese a ges SuppSupply voltagey o age Model systemt Surface /DIN-track mounting (with socket) Time-limit operation/eoeao/ DPDT 0s0.1 s to 30 mino30 110 VAC H3Y3 -2 self-resettinglf tti 220 VAC 24 VDC 4PDT H3Y3 -4 110 VAC 220 VAC 24 VDC Note: Specify the model number, supply voltage, and rated time when ordering. Ex. H3Y-2 110 VAC 1 s Rated time Supply voltage Accessories Back connecting socket Trackac mounted socket (see note )ou ed soc e (see o e ) Solder terminal Wire-wrap terminal PC terminal PYF08A, PYF08A-N, PYF08A-E PY08 PY08QN(2) PY08-02 PYF14A, PYF14A-N, PYF14A-E PY14 PY14QN(2) PY14-02 Note: Track mounted socket can be used as a front connecting socket. Specifications Time Ranges Rated time 1 s 5 s 10 s 30 s 60 s 3 min 30 min Time setting 0.1 to 1 s 0.2 to 5 s 0.5 to 10 s 1.0 to 30 s 2.0 to 60 s 0.1 to 3 min 1.0 to 30 min range 1H3Y H3Y Ratings Item H3Y-2/H3Y-4 Rated supply voltage 110, 220 VAC (50/60 Hz), 24 VDC (see note) Operating voltage range 85% to 110% of rated supply voltage Power consumption 100 VAC: Relay ON: 1.5 VA (1.3 W) Relay OFF: 0.8 VA (0.5 W) 200 VAC: Relay ON: 1.8 VA (1.5 W) Relay OFF: 1.2 VA (0.9 W) 24 VDC: Relay ON: 0.9 W Relay OFF: 0.07 W Control outputs H3Y-2: 5 A at 250 VAC, resistive load (cos = 1) H3Y-4: 3 A at 250 VAC, resistive load (cos = 1) Note: With DC ratings, single-phase full-wave rectified power sources may be used. Characteristics Accuracy of operating time 2% max. Setting error 10% (max. time division at rated voltage and room temperature) Reset time 0.1 s max. Influence of voltage 2% max. Influence of temperature 5% max. Insulation resistance 100 M min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min (between current-carrying terminals and exposed non-current-carrying metal parts) (see note) 2,000 VAC, 50/60 Hz for 1 min (between operating power circuit and control output) (see note) 2,000 VAC, 50/60 Hz for 1 min (between different pole contacts 2-pole model) (see note) 1,500 VAC, 50/60 Hz for 1 min (between different pole contacts 4-pole model) 1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts) Vibration resistance Destruction: 10 to 55 Hz with 1.0-mm double amplitude Malfunction: 10 to 55 Hz with 1.0-mm double amplitude 2 Shock resistance Destruction: 1,000 m/s (approx. 100G) 2 Malfunction: 100 m/s (approx. 10G) Ambient temperature Operating: 10C to 50C (with no icing) Ambient humidity Operating: 35% to 85% Life expectancy Mechanical: 10,000,000 operations min. (under no load at 1,800 operations/h) Electrical: H3Y-2: 500,000 operations min. (5 A at 250 VAC, resistive load at 1800 operations/h) H3Y-4: 200,000 operations min. (3 A at 250 VAC, resistive load at 1800 operations/h) EMC Emission Enclosure: EN55011 Group 1 class A Emission AC Mains: EN55011 Group 1 class A Immunity ESD: IEC801-2: 4 kV contact discharge (level 2) 4 kV air discharge (level 2) Immunity RF-interference: ENV50140: 10 V/m (80 MHz to 1 GHz) (level 3) Immunity Conducted Disturbance: ENV50141: 10 V (0.15 to 80 MHz) (level 3) Immunity Burst: IEC801-4: 2 kV power-line (level 3) 2 kV I/O signal-line (level 4) Approved standards UL (File No. E41515), CSA (File No. LR22310) Conforms to EN50081-2, EN50082-2 Weight Approx. 50 g Note: Terminal screw sections are excluded. 2