Solid-state Timer H3YN Miniature Timer with Multiple Time LR Ranges and Multiple Operating Modes Multiple operating modes include ON-delay, interval, flicker OFF start, or flicker ON start. Multiple time ranges from 0.1 s to 10 min or 1 min to 10 hr Minimizes stock: User selectable time range and mode by DIP switches. Pin configuration compatible with MY Power Relay. Conforms to EN 61812-1 and IEC 60664-1 for Low Voltage, and EMC Directives. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Refer to Safety Precautions on page 14. Ordering Information List of Models Specify both the model number and supply voltage when ordering. Example: H3YN-2 DC24 Short-time range model Long-time range model Supply voltage Time-limit contact (0.1 s to 10 min) (0.1 min to 10 h) DPDT H3YN-2 H3YN-21 24, 100 to 120, 200 to 230 VAC 12, 24, 48, 100 to 110, 125 VDC 4PDT H3YN-4 *1H3YN-41 *1 24 VDC 4PDT (Twin contacts) H3YN-4-Z *1, *2H3YN-41-Z *1, *2 Note: Sockets and Hold-down Clips are not included with the H3YN. They must be ordered separately. *1. Use the H3YN-4 or H3YN-41 Series when switching micro loads, and use the H3YN-4-Z or H3YN-41-Z Series when switching even smaller loads. *2. Only models with 24 VDC power supply are available. Accessories (Order Separately) Adapter, Mounting Plate, Clip Name/specification Model Flush mounting adapter Y92F-78 For 1 Socket PYP-1 Mounting Plate for Socket For 18 Sockets PYP-18 For PYF A Y92H-3 Clip For PY and PYF M Y92H-4 Note: For details, refer to Precautions for H3Y-series Timers on page 14. Socket Timer Square Sockets Contact Model Pin Connection Terminal Model DIN track mounting PYF08A DIN track mounting Front Connecting PYF08A-E (Finger-safe type) DPDT H3YN-2 8-pin Screw mounting PYF08F Solder terminal PY08 Back Connecting PCB terminal PY08-02 DIN track mounting PYF14A Front Connecting DIN track mounting PYF14A-E (Finger-safe type) 4PDT H3YN-4 14-pin Solder terminal PY14 Back Connecting PCB terminal PY14-02 Note: 1. Cannot be used with the H3Y- -0 (PCB terminals). 2. The PYFA-E has a finger-protection structure. Round crimp terminals cannot be used. Use forked crimp terminals. 3. For details, refer to Precautions for H3Y-series Timers on page 14. 1H3YN Specifications Ratings Item H3YN-2/-4/-4-Z H3YN-21/-41/-41-Z 0.1 s to 10 min (1 s, 10 s, 1 min, or 10 min max. 0.1 min to 10 h (1 min, 10 min, 1 h, or 10 h max. Time ranges selectable) selectable) 24, 100 to 120, 200 to 230 VAC (50/60 Hz) *1 Rated supply voltage *5, *6 12, 24, 48, 100 to 110, 125 VDC *2 Pin type Plug-in Operating mode ON-delay, interval, flicker OFF start, or flicker ON start (selectable with DIP switch) Operating voltage range 85% to 110% of rated supply voltage (12 VDC: 90% to 110% of rated supply voltage) *3 Reset voltage 10% min. of rated supply voltage *4 100 to 120 VAC: Relay ON: Approx. 1.8 VA (1.6 W) at 120 VAC, 60 Hz Relay OFF: Approx. 1 VA (0.6 W) at 120 VAC, 60 Hz 200 to 230 VAC: Relay ON: Approx. 2.2 VA (1.8 W) at 230 VAC, 60 Hz Relay OFF: Approx. 1.5 VA (1.1 W) at 230 VAC, 60 Hz 24 VAC: Relay ON: Approx. 1.8 VA (1.4 W) at 24 VAC, 60 Hz Relay OFF: Approx. 0.3 VA (0.2 W) at 24 VAC, 60 Hz 12 VDC: Relay ON: Approx. 1.1 W at 12 VDC Relay OFF: Approx. 0.1 W at 12 VDC Power consumption 24 VDC: Relay ON: Approx. 1.1 W at 24 VDC Relay OFF: Approx. 0.1 W at 24 VDC 48 VDC: Relay ON: Approx. 1.2 W at 48 VDC Relay OFF: Approx. 0.3 W at 48 VDC 100 to 110 VDC: Relay ON: Approx. 1.6 W at 110 VDC Relay OFF: Approx. 0.4 W at 110 VDC 125 VDC: Relay ON: Approx. 1.6 W at 125 VDC Relay OFF: Approx. 0.4 W at 125 VDC DPDT: 5 A at 250 VAC, resistive load (cos = 1) The minimum applicable load is 1 mA at 5 VDC (P reference value). Contact materials: Ag Control outputs 4PDT: 3 A at 250 VAC, resistive load (cos = 1) H3YN-4/-41 series: The minimum applicable load is 1 mA at 1 VDC (P reference value). H3YN-4-Z/-41-Z series: The minimum applicable load is 1 mA at 1 VDC (P reference value). Contact materials: Au-clad + Ag-alloy Ambient operating temperature -10C to 50C (with no icing) Storage temperature -25C to 65C Ambient operating humidity 35% to 85% *1. Do not use the output from an inverter as the power supply. Refer to Safety Precautions for All Timers for details on your OMRON website. *2. Single-phase, full-wave-rectified power supplies can be used. *3. When using the H3YN continuously in any place where the ambient temperature is in a range of 45C to 50C, supply 90% to 110% of the rated supply voltages (supply 95% to 110% with 12 VDC type). *4. Set the reset voltage as follows to ensure proper resetting. 100 to 120 VAC: 10 VAC max. 200 to 230 VAC: 20 VAC max. 100 to 110 VDC: 10 VDC max. *5. Refer to Safety Precautions for All Timers on your OMRON website when combining the Timer with an AC 2-wire proximity sensor. *6. A diode to prevent reverse voltages is provided only on models with a DC power supply. 2