Digital Timer H5AN DIN-sized (72 x 72 mm) Quartz Timer with Multiple Functions Wide time range from 1/100 seconds to 9999 hrs. Built-in power supply incorporated in timer enables direct connection of sensors and other components. Draw-out construction allows maintenance without disconnecting the wiring. Power supply freely selectable within a range of 100 to 240 VAC a DC-operated version is also available. Control outputs of both contact type and solid-state type simultaneously available. Seven operating modes (N, F, C, R, K, P, and Q) are available. Ordering Information Operation system Resetting system No. of digits Backup power supply Model function for memory protection Time-limit operation, Power-OFF resetting 4 digits (switch-selectable): Not provided H5AN-4D integrating operation (excluding -M), 0.01 to 99.99 s, 0.1 to 999.9 s, 1 to 9999 s, 0.1 Provided (approx. H5AN-4DM external resetting, to 999.9 min, 0.1 to 999.9 hrs, 1 to 9999 hrs, 10 years at 20C) manual resetting, automatic 1 s to 99 min 59 s, 1 min to 99 hrs 59 min resetting Note: 1. Specify both the model number and supply voltage when ordering. 2. The Timer is supplied with two mounting fixtures. H5AN Specifications Ratings Item H5AN-4D/H5AN-4DM Rated supply voltage H5AN-4D: 100 to 240 VAC (50/60 Hz), 12 to 24, 48, or 100 VDC (permissible ripple: 20% max.) H5AN-4DM: 100 to 240 VAC (50/60 Hz) 12 to 24 VDC (permissible ripple: 20% max.) Operating voltage range 85% to 110% of rated supply voltage Power consumption Approx. 10 VA (at 240 VAC, 50 Hz), approx. 5 W (at 24 VDC) Resetting system and gate Reset by power-OFF: min. power OFF time: 0.5 s input External reset or gate (common to contact and solid-state inputs): min. reset input signal width: 0.02 s One-shot output time 0.1 to 1 s (adjustable) Control outputs Contact output: SPDT, 3 A at 250 VAC, resistive load (cos = 1) Solid-state output: Open collector, 100 mA max. at 30 VDC max. Power supply for externally 12 VDC10%, 80 mA (permissible ripple: 5% max.) connected components Note: Inrush current was measured within the range shown below. Peak value Measurement time Time Characteristics Accuracy of operating time 0.01% 0.05 s max. (power OFF start), 0.005% 0.03 s max. (reset start) (see note) Setting error Influence of voltage Influence of temperature Insulation resistance 100 M min. (at 500 VDC) (between current-carrying terminal and exposed non-current carrying metal parts, between non-continuous contacts) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min (between current-carrying and non-current-carrying metal parts) 750 VAC, 50/60 Hz for 1 min (between non-continuous contacts) Vibration resistance Destruction: 10 to 55 Hz with 0.75-mm double amplitude Malfunction: 10 to 55 Hz with 0.5-mm double amplitude 2 Shock resistance Destruction: 300 m/s (approx. 30G) 2 Malfunction: 100 m/s (approx. 10G) Ambient temperature Operating: 10C to 55C Storage: 25C to 65C Ambient humidity Operating: 35% to 85% Life expectancy Mechanical: 10,000,000 operations min. (under no load at 1,800 operations/h) Electrical: 100,000 operations min. (3 A at 250 VAC, resistive load) Approved standards UL (File No. E41515), CSA (File No. LR22310) Weight Approx. 360 g Note: This value denotes the average of the repeat accuracy, setting error, and variations due to voltage and temperature changes. It includes the rise time of the power supply, and the operating time of the internal and output circuits.