General-purpose Limit Switch
HL-5000
CSM_HL-5000_DS_E_3_2
Economical, Miniature Limit Switch
Boasting Rigid Construction
The Head, Box, and Cover mate with ridged surfaces to
maintain strength.
A unique Head structure provides a large OT for smooth operation.
Easy-to-wire conduit opening design.
Ideal for application in printing machines, forming machines,
and light machines.
(High Switches with high sealing characteristics, such as WL or
D4C Switches, in locations subject to oil, water, or precipitation.)
Models with grounding terminals conform to the CE marking.
Approved by CCC (Chinese standard).
(Ask your OMRON representative for information on approved models.)
Be sure to read Safety Precautions on page 4 to 5 and
Safety Precautions for All Limit Switches.
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Model Number Structure Specifications
(Not all combinations are possible. Ask
Model Number Legend Approved Standards
your OMRON representative for details.)
HL-5@@
Agency Standard File No.
`HL-5
(1)(2)
CCC (CQC) GB14048.5 2003010303077624
(1) Actuators
Note: Ask your OMRON representative for information on approved models.
000: Roller lever
Ratings
030: Adjustable roller lever
050: Adjustable rod lever
Non-inductive load (A) Inductive load (A)
100: Sealed plunger
Rated Resistive Inductive
Lamp load Motor load
200: Sealed roller plunger
voltage load load
300: Coil spring
NC NO NC NO NC NO NC NO
(2) Ground Terminal Specifications 125 VAC 51.5 0.7 32 1
250 VAC 5 1 0.5 3 1.5 0.8
Blank : Without ground terminal
12 VDC 53 43
G : With ground terminal/M5 tapping on the rear side
24 VDC 53 43
125 VDC 0.4 0.2
Ordering Information
250 VDC 0.4 0.2
Note: 1. The above figures are for steady-state currents.
Actuator Model
2. Inductive loads have a power factor of 0.4 min. (AC) and a time
constant of 7 ms max. (DC).
HL-5000 *
Roller lever
3. Lamp load has an inrush current of 10 times the steady-state current.
4. Motor load has an inrush current of 6 times the steady-state current.
Adjustable
HL-5030 *
NC 24 A max.
Inrush
roller lever
current
NO 12 A max.
Adjustable
HL-5050 *
Approved Standard Ratings
rod lever
CCC (GB14048.5)
Sealed
HL-5100 *
Applicable category and ratings
plunger
AC-15 3 A/250 VAC
Sealed roller
HL-5200
plunger
Coil spring HL-5300
* HL-5000 Limit Switches are offered with a choice of ground terminal/M5
tapping on the rear side conforming to various standards. When placing an
order, add the code to the model number to indicate if ground terminal/M5
tapping on the rear side is required.
-G: with ground terminal/M5 tapping on the rear side.
1HL-5000
Characteristics Engineering Data
Electrical Durability (cos dia. =1)
Degree of protection IP65
(Operating temperature: +5C to +35C,
10,000,000 operations min. (under
Mechanical
Operating humidity: 40% to 70%RH)
rated conditions)
Durability *
Electrical See the following Electrical Durability.
Operating frequency:
1,000 30 operations/min
Operating speed 5 mm/s to 0.5 m/s
125 VAC (cos dia. = 1)
Mechanical 120 operations/min
Operating
frequency
Electrical 30 operations/min
Insulation resistance 100 M min. (at 500 VDC)
Contact resistance 25 m max. (initial value)
1,000 VAC, 50/60 Hz for 1 min between
500
terminals of the same polarity
1,500 VAC, 50/60 Hz for 1 min between
Dielectric strength current-carrying metal parts and ground
1,500 VAC, 50/60 Hz for 1 min between
each terminal and non-current-carrying
metal part
0
12 3 4 5 6
Rated frequency 50/60 Hz
Switching current (A)
Vibration
Malfunction 10 to 55 Hz, 1.5-mm double amplitude
resistance
2
Destruction 1,000 m/s max.
Shock
2
resistance
Malfunction 300 m/s max.
Ambient operating
5C to +65C (with no icing)
temperature
Ambient operating
35% to 95%RH
humidity
Weight Approx. 130 to 190 g
Note: 1. The above figures are initial values.
2. The above characteristics may vary depending on the model. For
further details, contact your OMRON sales representative.
* The values are calculated at an operating temperature of +5C to +35C, and
an operating humidity of 40% to 70%RH. Contact your OMRON sales
representative for more detailed information on other operating environments.
Structure and Nomenclature
Structure Contact Form
Za
(NO) 4 3 (NO)
Resin roller
Lever
(NC) 1 2 (NC)
Head
Cover
Built-in switch
Connector
2
4
Durability (x 10 operations)