Temperature Indicator K3HB-H CSM K3HB-H DS E 14 4 New High-speed, High-precision Temperature Indicator Visual confirmation of judgement results through display colors that switch between red and green. *1 Capable of high-speed sampling at 50 times per second (20 ms). High-resolution of 0.01C with platinum-resistance thermometer Pt100 input. Thermocouple sensor inputs also support a resolution of 0.1C for all ranges. Temperature input shift is easily set using two points. Display Input compensation value 2 After compensation Input compensation For the most recent information on models that have been certified for value 1 Before safety standards, refer to your OMRON website. compensation Input 0 Input Input compensation compensation input value 1 input value 2 Series expanded to include DeviceNet models. *2 UL certification approval (Certification Mark License). CE Marking conformance by third party assessment body. Water-resistant enclosure conforms to NEMA 4X (equivalent to IP66). *1 Visual confirmation of judgement results is not supported on models that do not have an output or models that do not support DeviceNet. You can change the display color by setting it, but you cannot switch it based on the judgement results. *2 DeviceNet models have a depth of 97 mm. Refer to Safety Precautions for All Digital Panel Meters. Model Number Structure Model Number Legend Base Units and Optional Boards can be ordered individually or as sets. Base Units Base Units with Optional Boards K3HB-H K3HB-H - 15 12 34 5 2. Sensor Power Supply/Output Type Code 1. Input Sensor Code None: None TA: Temperature input CPA: Relay output (PASS: SPDT) + Sensor power supply Thermocouple input/Platinum-resistance thermometer input (12 VDC +/10%, 80 mA) (See note 1.) 5. Supply Voltage Linear current output (0 to 20 or 4 to 20 mA DC) + Sensor power supply L1A: (12 VDC +/10%, 80 mA) (See note 2.) 100-240 VAC: 100 to 240 VAC L2A: Linear voltage output (0 to 5, 1 to 5, or 0 to 10 VDC) + Sensor power 24 VAC/VDC: 24 VAC/VDC supply (12 VDC +/10%, 80 mA) (See note 2.) A: Sensor power supply (12 VDC +/10%, 80 mA) FLK1A: Communications (RS-232C) + Sensor power supply (12 VDC +/10%, 80 mA) (See note 2.) FLK3A: Communications (RS-485) + Sensor power supply (12 VDC +/10%, 80 mA) (See note 2.) Note: 1. CPA can be combined with relay outputs only. 2. Only one of the following can be used by each Digital Indicator: RS-232C/ RS-485 communications, a linear output, or DeviceNet communications. Optional Boards Sensor Power Supply/Output Boards 3. Relay/Transistor Output Type Code None: None K33- C1: Relay contact (H/L: SPDT each) C2: Relay contact (HH/H/LL/L: SPST-NO each) 2 T1: Transistor (NPN open collector: HH/H/PASS/L/LL) Relay/Transistor Output Boards T2: Transistor (PNP open collector: HH/H/PASS/L/LL) BCD *: BCD output + transistor output (NPN open collector: HH/H/PASS/L/LL) K34- DRT: DeviceNet (See note 2.) 3 * A Special BCD Output Cable (sold separately) is required. 4. Event Input Type Code Event Input Boards None: None 1: 5 inputs (M3 terminal blocks), NPN open collector K35- 2 *: 8 inputs (10-pin MIL connector), NPN open collector 4 3: 5 inputs (M3 terminal blocks), PNP open collector 4 *: 8 inputs (10-pin MIL connector), PNP open collector * There is no bank selection forNon andDeviceNe types ofTransistor Output Type Cod. Note: The following combinations are not possible. Communications (FLK A) + DeviceNet (DRT) Communications (FLK A) + BCD output (BCD) Linear current/voltage (L A) + DeviceNet (DRT) 1K3HB-H Accessories (Sold Separately) K32-DICN: Special Cable (for event inputs, with 8-pin connector) K32-BCD: Special BCD Output Cable Watertight Cover Rubber Packing Model Model Y92A-49N K32-P1 Note: Rubber packing is provided with the Controller. Specifications Ratings Power supply voltage 100 to 240 VAC (50/60 Hz), 24 VAC/VDC, DeviceNet power supply: 24 VDC Allowable power supply voltage range 85% to 110% of the rated power supply voltage, DeviceNet power supply: 11 to 25 VDC Power consumption 100 to 240 V: 18 VA max. (max. load) (See note 1.) 24 VAC/DC: 11 VA/7 W max. (max. load) Current consumption DeviceNet power supply: 50 mA max. (24 VDC) Input Platinum-resistance thermometer: Pt100 Thermocouple: K, J, T, E, L, U, N, R, S, B, W A/D conversion method Delta-Sigma method External power supply See Sensor Power Supply/Output Type Codes Event inputs Timing input NPN open collector or no-voltage contact signal (See note 2.) ON residual voltage: 3 V max. ON current at 0 : 17 mA max. Max. applied voltage: 30 VDC max. OFF leakage current: 1.5 mA max. Startup compensa- NPN open collector or no-voltage contact signal tion timer input ON residual voltage: 2 V max. ON current at 0 : 4 mA max. Hold input Max. applied voltage: 30 VDC max. OFF leakage current: 0.1 mA max. Reset input Bank input Output ratings Relay output 250 VAC, 30 VDC, 5 A (resistive load) (depends on the Mechanical life expectancy: 5,000,000 operations, Electrical life expectancy: 100,000 operations model) Transistor output Maximum load voltage: 24 VDC, Maximum load current: 50 mA, Leakage current: 100 A max. Linear output Linear output 0 to 20 mA DC, 4 to 20 mA DC: Load: 500 max, Resolution: Approx. 10,000, Output error: 0.5% FS Linear output 0 to 5 VDC, 1 to 5 VDC, 0 to 10 VDC: Load: 5 k max, Resolution: Approx. 10,000, Output error: 0.5% FS (1 V or less: 0.15 V not output for 0 V or less) Display method Negative LCD (backlit LED) display 7-segment digital display (Character height: PV: 14.2 mm (green/red) SV: 4.9 mm (green) Main functions Temperature input shift, measurement operation selection, averaging, previous average value comparison, zero-limit, output hysteresis, output OFF delay, output test, display value selection, display color selection, key protection, bank selection, display refresh period, maximum/minimum hold, reset Ambient operating temperature 10 to 55C (with no icing or condensation) Ambient operating humidity 25% to 85% Storage temperature 25 to 65C (with no icing or condensation) Altitude 2,000 m max. Accessories Watertight packing, 2 fixtures, terminal cover, unit stickers, instruction manual. DeviceNet models also include a DeviceNet connector (Hirose HR31-5.08P-5SC(01)) and crimp terminals (Hirose HR31-SC-121) (See note 3.) Note: 1. DC power supply models require a control power supply capacity of approximately 1 A per Unit when power is turned ON. Particular attention is required when using two or more DC power supply models. The OMRON S8VS-series DC Power Supply Unit is recommended. 2. PNP input types are also available. 3. For K3HB-series DeviceNet models, use only the DeviceNet Connector included with the product. The crimp terminals provided are for Thin Ca- bles. 2