General-purpose Relay MY New model Versatile and Function-filled Miniature Power Relay for Sequence Control and Power Switching Applications Models with lockable test buttons now available. Many variations possible through a selection of operation indi- cators (mechanical and LED indicators), lockable test button, built-in diode and CR (surge suppression), bifurcated contacts, etc. Arc barrier standard on 4-pole Relays. Dielectric strength: 2,000 VAC (coil to contact) Environment-friendly cadmium-free contacts. Safety standard approvals obtained. LR Wide range of Sockets (PY, PYF Series) and optional parts are available. Max. Switching Current: 2-pole: 10 A, 4-pole: 5 A Provided with nameplate. Ordering Information Relays Standard Coil Polarity Type Contact form Plug-in socket/Solder terminals Without LED indicator Standard with LED indicator With LED indicator and lockable test button Standard DPDT MY2N MY2IN MY2 4PDT MY4N MY4IN MY4 4PDT (bifurcated) MY4ZN MY4ZIN MY4Z With built-in diode DPDT MY2N-D2 MY2IN-D2 --- (DC only) 4PDT MY4N-D2 MY4IN-D2 --- 4PDT (bifurcated) MY4ZN-D2 MY4ZIN-D2 --- With built-in CR DPDT MY2N-CR MY2IN-CR --- (220/240 VAC, 110/120 VAC 4PDT MY4N-CR MY4IN-CR --- only) 4PDT (bifurcated) MY4ZN-CR MY4ZIN-CR --- Reverse Coil Polarity Type Contact form Plug-in socket/Solder terminals With LED indicator With LED indicator and lockable test button Standard (DC only) DPDT MY2N1 MY2IN1 4PDT MY4N1 MY4IN1 4PDT (bifurcated) MY4ZN1 MY4ZIN1 With built-in diode DPDT MY2N1-D2 MY2IN1-D2 (DC only) 4PDT MY4N1-D2 MY4IN1-D2 4PDT (bifurcated) MY4ZN1-D2 MY4ZIN1-D2 Note: When ordering, add the rated coil voltage and (s) to the model number. Rated coil voltages are given in the coil ratings table. Example: MY2 6VAC (S) New model Rated coil voltage General-purpose Relay MY New model 1 Accessories (Order Separately) Sockets Poles Front Mounting Front-mounting Back-mounting Socket Socket (DIN-track/ Socket (DIN-track/ Solder terminals Wire-wrap terminals PCB terminals screwless clamp screw mounting) SLC ) Without clip With clip Without clip With clip 2 PYF08S PYF08A-E PY08 PY08-Y1 PY08QN PY08QN-Y1 PY08-02 PYF08A-N PY08QN2 PY08QN2-Y1 4 PYF14S PYF14A-E PY14 PY14-Y1 PY14QN PY14QN-Y1 PY14-02 PYF14A-N PY14QN2 PY14QN2-Y1 PYF14-ESS PYF14-ESN Socket Hold-down Clip Pairing Relay type Poles Front Mounting Socket Front-connecting Socket (DIN-track/ Back-connecting Socket (DIN-track/screwless clamp screw mounting) Solder/Wire-wrap terminals PCB terminals SLC ) Socket Clip Socket Clip Socket Clip Without 2-pole 2 PYF08S PYCM-08S PYF08A-E PYC-A1 PY08(QN) PYC-P PY08-02 PYC-P test button PYF08A-N PYC-P2 PYC-P2 4 PYF14S PYCM-14S PYF14A-E PY14(QN) PY14-02 PYF14A-N PYF14-ESS PYC0 (metal) PYF14-ESN PYC35 (plastic) 2-pole 2 PYF08S PYCM-08S PYF08A-E PYC-E1 PY08(QN) PYC-P2 PY08-02 PYC-P2 test button PYF08A-N Mounting Plates for Sockets Socket model For 1 Socket For 18 Sockets For 36 Sockets PY08, PY08QN(2), PY14, PY14QN(2) PYP-1 PYP-18 PYP-36 Note: PYP-18 and PYP-36 can be cut into any desired length in accordance with the number of Sockets. Track and Accessories Supporting Track (length = 500 mm) PFP-50N Supporting Track (length = 1,000 mm) PFP-100N, PFP-100N2 End Plate PFP-M Spacer PFP-S Specifications Coil Ratings Rated voltage Rated current Coil Coil inductance Must Must Max. Power resistance (reference value) operate release voltage consumption voltage voltage (approx.) 50 Hz 60 Hz Arm. OFF Arm. ON % of rated voltage AC 6 V* 214.1 mA 183 mA 12.2 0.04 H 0.08 H 80% max. 30% min. 110% 1.0 to 1.2 VA (60 Hz) 12 V 106.5 mA 91 mA 46 0.17 H 0.33 H 24 V 53.8 mA 46 mA 180 0.69 H 1.30 H 48/50 V* 24.7/ 21.1/ 788 3.22 H 5.66 H 25.7 mA 22.0 mA 110/120 V 9.9/10.8 mA 8.4/9.2 mA 4,430 19.20 H 32.1 H 0.9 to 1.1 VA (60 Hz) 220/240 V 4.8/5.3 mA 4.2/4.6 mA 18,790 83.50 H 136.4 H DC 6 V* 151 mA 39.8 0.17 H 0.33 H 10% min. 0.9 W 12 V 75 mA 160 0.73 H 1.37 H 24 V 37.7 mA 636 3.20 H 5.72 H 48 V* 18.8 mA 2,560 10.60 H 21.0 H 100/110 V 9.0/9.9 mA 11,100 45.60 H 86.2 H Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C with tolerances of +15%/20% for rated currents and 15% for DC coil resistance. 2. Performance characteristic data are measured at a coil temperature of 23C. 3. AC coil resistance and impedance are provided as reference values (at 60 Hz). 4. Power consumption drop was measured for the above data. When driving transistors, check leakage current and connect a bleeder resistor if required. 5. Rated voltage denoted by * will be manufactured upon request. Ask your OMRON representative. 2 General-purpose Relay MY New model