New Product Miniature Power Relays MY(S) MY(S) Versatile plug-in Relay Reduces wiring work by 60% when combined with the PYF-PU Push-In Plus Socket (according to actual OMRON measurements). 10 A (DPDT) and 5 A (4PDT) Gold-clad contacts (MY4(S)) Test button (lockable) Wide portfolio includes hermetically sealed and latching types 2.6 mm wide pins offer higher conductivity and less temperature increase The compliant standards depend on the model. For details, refer to information provided for individual models. Refer to the Common Relay Precautions and Safety Precautions on page 34. Model Number Structure Coil Polarity Type Contact form Plug-In socket/solder terminals Flange mounting (DC case) * With LED indicator With LED Indicator Without LED and Lockable test Indicator button Type 1 Standard model DPDT MY2N(S) MY2IN(S) MY2(S) MY2F DPDT (Bifurcated) MY2ZN --- --- --- 4PDT MY4N(S) MY4IN(S) MY4(S) MY4F 4PDT (Bifurcated) MY4ZN(S) MY4ZIN(S) MY4Z(S) MY4ZF With Built-in diode DPDT MY2N-D2(S) MY2IN-D2(S) --- --- (DC only) DPDT (Bifurcated) MY2ZN-D2 --- --- --- 4PDT MY4N-D2(S) MY4IN-D2(S) --- --- 4PDT (Bifurcated) MY4ZN-D2(S) MY4ZIN-D2(S) --- --- With Built-in CR DPDT MY2N-CR(S) MY2IN-CR(S) --- --- (AC only) 4PDT MY4N-CR(S) MY4IN-CR(S) --- --- 4PDT (Bifurcated) MY4ZN-CR(S) MY4ZIN-CR(S) --- --- High reliability contacts 4PDT (Crossbar --- --- MY4Z-CBG --- Bifurcated) Plastic Sealed 4PDT MYQ4N --- --- --- 4PDT (Bifurcated) --- --- MYQ4Z --- Lactching (coil latching) DPDT --- --- MY2K --- Hermetic 4PDT --- --- MY4H --- 4PDT (Bifurcated) --- --- MY4ZH --- Type 2 Standard model DPDT MY2N1(S) MY2IN1(S) --- --- 4PDT MY4N1(S) MY4IN1(S) --- --- 4PDT (Bifurcated) MY4ZN1(S) MY4ZIN1(S) --- --- With Built-in diode DPDT MY2N1-D2(S) MY2IN1-D2(S) --- --- (DC only) 4PDT MY4N1-D2(S) MY4IN1-D2(S) --- --- 4PDT (Bifurcated) MY4ZN1-D2(S) MY4ZIN1-D2(S) --- --- * In case of AC coil type relay, please select them fromType 1 of Coil Polality. Refer to Connection Socket and Mounting Bracket Selection Table on page 25 in Options for information on the possible combinations of Models with Plug-in Terminals and Sockets. 1MY(S) Contents Model Number Structure............................................................................................. 1 Specifications Coil Ratings ............................................................................................................ 2 MY2(S)/MY4(S)/MY4Z(S).............................................................................................. 3 Engineering Data ......................................................................................................... 6 Detailed Information on Models Certified for Safety Standards, MY2(S)/MY4(S)/MY4Z(S)......... 8 Models Other Than MY(S) Models MY2ZN ..................................................................................................................... 9 MY F..................................................................................................................... 11 Detailed Information on Models Certified for Safety Standards, MY2ZN and MY F.......... 14 MY4Z-CBG ............................................................................................................ 15 MYQ4 ..................................................................................................................... 17 MY2K ..................................................................................................................... 19 MY4(Z)H................................................................................................................. 21 Socket for MY............................................................................................................. 23 Options.................................................................................................................. 25 Safety Precautions .................................................................................................... 34 Specifications Coil Ratings MY(S) Must Must Coil inductance Max. Power Rated current operate release Coil (reference value) voltage Rated voltage consumption voltage voltage resistance (approx.) 50 Hz 60 Hz Arm. OFF Arm. ON % of rated voltage 6 V 214.1 mA 183 mA 12.2 0.04 H 0.08 H 12 V 106.5 mA 91 mA 46 0.17 H 0.33 H 24 V 53.8 mA 46 mA 180 0.69 H 1.30 H Approx. 0.9 to AC 30% min. 1.3 VA (60 Hz) 48/50 V 24.7/25.7 mA 21.1/22.0 mA 788 3.22 H 5.66 H 110/120 V 9.9/10.8 mA 8.4/9.2 mA 4,430 19.20 H 32.1 H 220/240 V 4.8/5.3 mA 4.2/4.6 mA 18,790 83.50 H 136.4 H 80% max. 110% 6 V 151 mA 39.8 0.17 H 0.33 H 12 V 75 mA 160 0.73 H 1.37 H DC 10% min. 0.9 W 24 V 37.7 mA 636 3.20 H 5.72 H 48 V 18.8 mA 2,560 10.60 H 21.0 H 100/110 V 9.0/9.9 mA 11,100 45.60 H 86.2 H Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C with tolerances of +15%/20% for rated currents and 15% for DC coil resistance. 2. Performance characteristic data are measured at a coil temperature of 23C. 3. AC coil resistance and impedance are provided as reference values (at 60 Hz). 4. Power consumption drop was measured for the above data. When driving transistors, check leakage current and connect a bleeder resistor if required. MY2ZN, MY F, MY4(Z)H Item Rated current (mA) Coil inductance (H) Must- Must- Coil resistance Maximum Power consumption operate release Rated Armature Armature () voltage (V) (VA, W) 50 Hz 60 Hz voltage (V) voltage (V) voltage (V) OFF ON 12 106.5 91 46 0.17 0.33 24 53.8 46 180 0.69 1.3 100/110 11.7/12.9 10/11 3,750 14.54 24.6 Approx. 0.9 to 1.3 VA *2 AC 30% min. (60 Hz) 110/120 9.9/10.8 8.4/9.2 4,430 19.2 32.1 200/220 6.2/6.8 5.3/5.8 12,950 54.75 94.07 110% of rated *1 80% max. voltage 220/240 4.8/5.3 4.2/4.6 18,790 83.5 136.4 12 75 160 0.73 1.37 24 36.9 650 3.2 5.72 *2 DC 10% min. Approx. 0.9 48 18.5 2,600 10.6 21.0 100/110 9.1/10 11,000 45.6 86.2 Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C with tolerances of +15%/20% for the AC rated current and 15% for the DC coil resistance. 2. The AC coil resistance and inductance values are reference values only (at 60 Hz). 3. Operating characteristics were measured at a coil temperature of 23C. 4. The maximum voltage capacity was measured at an ambient temperature of 23C. *1. There is variation between products, but actual values are 80% max. To ensure operation, apply at least 80% of the rated value *2. There is variation between products, but actual values are 30% minimum for AC and 10% minimum for DC. To ensure release, use a value that is lower than the specified value. Note: Refer to page 19 for the coil specifications of the MY2K. 2