New Product Switch Mode Power Supply (15/30/60/90/120/180/240/480-W Models) S8VS 60/90/120/180/240/480-W Models New Models with Indication Monitor and Simple Functions for Easy System Commissioning New 90-W models with indication monitor that conform to UL Class 2 Output standards. New models with screwless terminal blocks and indication monitor. Status displayed on 3-digit, 7-segment display. Safety standards: UL 508/60950-1, CSA C22.2 No. 107.1/60950-1 For the most recent information on models that have been certified for EN 50178 (= VDE 0160) safety standards, refer to your OMRON website. EN 60950-1 (= VDE 0805 Teil 1) Input conditions: DC input is also possible from 80 to 370 VDC (Not compliant with EC Directives and other safety standards.) 15/30-W Models Compact, Thin Power Supplies That Mount Just About Anywhere to Contribute to Control Panel Downsizing Compact and thin: 22.5 85 96.5 mm (W H D). Three mounting directions (standard, horizontal, facing horizontal). Mounting directly to the panel is possible. Safety standards: For the most recent information on models that have been certified for UL 508/60950-1, safety standards, refer to your OMRON website. CSA C22.2 No.107.1/60950-1, EN 50178 (= VDE 0160), EN 60950-1 (= VDE 0805 Teil 1) Input conditions: DC input is also possible from 80 to 370 VDC (Not compliant with EC Directives and other safety standards.) Features Common to All Models Mount to DIN Rail. Complies with SEMI F47-0706 (200-VAC input). RoHS-compliant. Refer to Safety Precautions for All Power Supplies and Safety Precautions on page 32. 1S8VS Model Number Structure Model Number Legend Note: Not all combinations are possible. Refer to List of Models in Ordering Information, below. S8VS- - 123 4 5 6 1. Power Ratings 4. Alarm output 015: 15 W None: Sinking (Emitter COM) * 030: 30 W P: Sourcing (Collector COM) 060: 60 W Note: No alarm output possible with 60-W models. 090: 90 W * Both sinking and sourcing outputs are available for 480-W models. 120: 120 W 5. UL Class 2 Output Standards (UL 1310) 180: 180 W None: Does not conform. * 240: 240 W S: Conforms. 480: 480 W * 15-W, 30-W, and 60-W models conform to Class 2 output standards (UL 1310). 2. Output voltage Note: The S option is available only for 90-W models. 05: 5 V 12: 12 V 6. Terminal Block Form 24: 24 V None: Screw terminal block F: Screwless terminal block 3. Indication monitor None: Without indication monitor (standard model) A: With indication monitor (maintenance forecast monitor) B: With indication monitor (total run time monitor) BE: With indication monitor but without alarm output (total run time monitor) Note: Estimates can be provided for coatings and other specifications that are not given in the datasheet. Ask your OMRON representative for details. 2