V600-D23P66N V600-D23P66N Electromagnetic Inductive RFID Data Carrier V600-D23P66N 530 kHz Data Carrier for Use in Metal and Non-metal Applications Passive tag technology (no internal power source for communications) Operates at 530 kHz EEPROM memory 10-year data storage 256 Bytes memory capacity -40C to 150C storage temperature -25C to 85C operation temperature 100,000 read/write cycles at -20C to 85C 800,000 read/write cycles at -20C to 0C Durable PPS resin construction Up to 45 mm transmission distance (application dependent) Integrated surface mounting system For non-metal applications (metal applications use V600-A86 Tag Bracket) Capable of virtually unlimited number of Read-Only cycles Ordering Information DATA CARRIER Item Description Part number Data carrier Type Electromagnetic inductive V600-D23P66N Memory EEPROM 256 Bytes Construction PPS resin Enclosure rating IEC60529, IP68 Size 34 mm (W) x 34 mm (D) x 3.5 mm (H) Specifications GENERAL The communications distance priority mode or communications time priority mode can be set on the serial interface ID controller or ID sensor unit via the communications mode DIP switches. The communications distance priority mode is always used for parallel interface ID controllers. These specifications are the certified performance when taking into consideration variations in ambient temperatures and products. 1V600-D23P66N V600-D23P66N DATA CARRIER MEMORY Memory capacity Usable memory 254 Bytes 00(H) - FD(H) Total memory 256 Bytes FE(H) - FF(H) Data storage Data maintained after it is encoded 10 years max. Memory life -20C to 85C (-4F to 185F) 100,000 times per address -20C to 60C (-4F to 140F) 300,000 times per address -20C to 25C (-4F to 77F) 400,000 times per address -20C to 0C (-4F to 32F) 800,000 times per address CHARACTERISTICS 2 Vibration resistance-destruction 10 to 2000 Hz, 1.5 mm double amplitude and 150 m/s for 15 min 10 times each X, Y and Z directions 2 Shock resistance-destruction 500 m/s 3 times each in X, Y and Z directions (18 times total) STORAGE CONDITIONS Ambient temperature -40C to 150C (-40F to 302F) (There should be no icing.) Heat shock resistance -10C to 150C (14F to 302F) in 30 minute cycles 1000 cycles High temperature resistance 150C (302F) continuously for 1000 hours Ambient humidity 35% to 95% relative humidity (no condensation) Environment Do not apply excessive pressure, shock or corrosive gas which may deform the product OPERATION CONDITIONS Ambient temperature -20C to 85C (-4F to 185F) (There should be no icing.) Ambient humidity 35% to 95% relative humidity (no condensation) Environment Do not expose the product to corrosive gases such as hydrogen sulfide gas or organic solvents. Avoid exposure to direct sunlight Avoid any condition that could cause physical damage Installation MUTUAL INTERFERENCE Data carriers must be at least 250 mm apart. Data carrier Data carrier 250 mm min. DATA CARRIER AND READ/WRITE HEAD INSTALLATION CONDITIONS FOR NON-METAL APPLICATIONS Steel Steel V600-D23P66N V600-D23P66N Non-metal material V600-HS51 Non-metal material V600-H11/V600-H07 V600-H12/V600-HS61 V600-HS63/V600-HS67 2