1N5400 thru 1N5408 1N5404 and 1N5406 are Preferred Devices Axial-Lead Standard Recovery Rectifiers Lead mounted standard recovery rectifiers are designed for use in power supplies and other applications having need of a device with the following features: 1N5400 thru 1N5408 MAXIMUM RATINGS Rating Symbol 1N5400 1N5401 1N5402 1N5404 1N5406 1N5407 1N5408 Unit Peak Repetitive Reverse Voltage V 50 100 200 400 600 800 1000 V RRM Working Peak Reverse Voltage V RWM DC Blocking Voltage V R Nonrepetitive Peak Reverse Voltage V 100 200 300 525 800 1000 1200 V RSM Average Rectified Forward Current I 3.0 A O (Single Phase Resistive Load, 1/2 in. Leads, T = 105C) L Nonrepetitive Peak Surge Current I 200 (one cycle) A FSM (8 ms Single HalfSineWave) Operating and Storage Junction T 65 to +150 C J Temperature Range T 65 to +175 stg Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect device reliability. THERMAL CHARACTERISTICS Characteristic Symbol Typ Unit Thermal Resistance, JunctiontoAmbient (PC Board Mount, 1/2 in. Leads) R 53 C/W JA ELECTRICAL CHARACTERISTICS Characteristic Symbol Min Typ Max Unit Forward Voltage (I = 3.0 A, T = 25C) v 1.0 V F A F Reverse Current (Rated DC Voltage) I A R T = 25C 10 A T = 100C 50 A Ratings at 25C ambient temperature unless otherwise specified. 60 Hz resistive or inductive loads. For capacitive load, derate current by 20%.