MUR3020PTG, SUR83020PTG, MUR3040PTG, MUR3060PTG, SUR83060PTG MUR3020PTG, SUR83020PTG, MUR3040PTG, MUR3060PTG, SUR83060PTG MAXIMUM RATINGS (Per Leg) MUR3020PTG/ MUR3060PTG/ SUR83020PTG SUR83060PTG Rating Symbol MUR3040PTG Unit Peak Repetitive Reverse Voltage V 200 400 600 V RRM Working Peak Reverse Voltage V RWM DC Blocking Voltage V R Average Rectified Forward Current (Rated V ) I A R F(AV) Per Leg 15 T = 150C 15 T = 145C C C Per Device 30 T = 150C 30 T = 145C C C Peak Rectified Forward Current, Per Leg I 30 T = 150C 30 T =145C A FRM C C (Rated V , Square Wave, 20 kHz) R Nonrepetitive Peak Surge Current (Surge applied at rated load conditions, halfwave, single phase, 60 Hz) I 200 A FSM Per Leg Operating Junction and Storage Temperature T , T 65 to +175 C J stg THERMAL CHARACTERISTICS (Per Diode Leg) Maximum Thermal Resistance, C/W Junction toCase R 1.5 JC Junction toAmbient 40 R JA ELECTRICAL CHARACTERISTICS (Per Diode Leg) Maximum Instantaneous Forward Voltage (Note 1) V V F (I = 15 Amp, T = 150C) 0.85 1.12 1.2 F C (I = 15 Amp, T = 25C) 1.05 1.25 1.5 F C Maximum Instantaneous Reverse Current (Note 1) i A R (Rated DC Voltage, T = 150C) 500 1000 J (Rated DC Voltage, T = 25C) 10 10 J Maximum Reverse Recovery Time t 35 60 ns rr (i = 1.0 A, di/dt = 50 A/ s) F Maximum ratings are those values beyond which device damage can occur. Maximum ratings applied to the device are individual stress limit values (not normal operating conditions) and are not valid simultaneously. If these limits are exceeded, device functional operation is not implied, damage may occur and reliability may be affected. 1. Pulse Test: Pulse Width = 300 s, Duty Cycle 2.0%.