Pressure Sensor/PS(ADP4), PF(ADP1) Pressure Sensor PS/PF PS Pressure Sensor PF Pressure Sensor High precision pressure sensor (without amp.) Features Compact size (PS type) High accuracy and liner characteristic Broad line-up RoHS compliant Typical Applications Industrial use: pressure switches and pneumatic components, compressed air pressure measuring devices and airbeds Medical use: blood pressure meters, oxygen generator and airbeds Others: pressure sensing devices for air pressure mediums Ordering Information ADP Product name Terminal profile and direction Rated pressure Type Bridge resistance 1 PF pressure sensor 1 DIP terminal 0 4.9 kPa 1 Standard type PF 5 k 0 4 PS pressure sensor (Direction opposite to the 2 34.3 kPa (With glass base) PS 5 k pressure inlet direction) 3 49.0 kPa 2 Economy type 3 3.3 k 4 98.1 kPa (Without glass base) 5 196.1 kPa 6 343.2 kPa 7 490.3 kPa 2 DIP terminal 8 833.6 kPa (Pressure inlet direction) 9 980.7 kPa Note : Some part numbers may not be available A 40.0 kPa depending on the combination. Please refer to the Table of Product Types. Types Part No. Brige resistance PS pressure sensor PF pressure sensor 5 k 3.3 k 5 k 3.3 k Terminal DIP terminal: DIP terminal: SMD terminal DIP terminal: DIP terminal: DIP terminal: DIP terminal: DIP terminal: DIP terminal: Direction opposite Pressure inlet Direction opposite Pressure inlet Direction opposite Pressure inlet Direction opposite Pressure inlet Pressure to the pressure direction to the pressure direction to the pressure direction to the pressure direction inlet direction inlet direction inlet direction inlet direction 4.9kPa ADP41010 ADP42010 ADP1101 ADP1201 34.3kPa ADP41210 ADP42210 ADP1121 ADP1221 49.0kPa ADP41310 ADP42310 ADP1131 ADP1231 98.1kPa ADP41410 ADP42410 ADP4932 ADP41413 ADP42413 ADP1141 ADP1241 Standard type (with glass 196.1kPa ADP41510 ADP42510 ADP1151 ADP1251 base) 343.2kPa ADP41610 ADP42610 ADP1161 ADP1261 490.3kPa ADP41710 ADP42710 ADP1171 ADP1271 833.6kPa ADP41810 ADP42810 ADP1181 ADP1281 980.7kPa ADP41910 ADP42910 ADP41913 ADP42913 ADP1191 ADP1291 ADP4933 Economy type (without glass 40.0kPa ADP41A23 ADP42A23 ADP11A23 ADP12A23 base) Standard packing : Carton : 100 pcs. Case : 1,000 pcs. Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. 00 Aug. 2015Pressure Sensor/PS(ADP4), PF(ADP1) Rating Economy type Type Standard type (With glass base) (Without glass base) Type of pressure Gauge pressure 2 Pressure medium Air 3 3 Rated pressure (Unit: kPa) 4.9 34.3 to 343.2 490.3 833.6 980.7 98.1 980.7 40.0 1.5 times of the Twice of the 1.5 times of the Twice of the Max. applied pressure Twice of the rated pressure rated pressure rated pressure rated pressure rated pressure Bridge resistance 5,000 1,000 3,300 700 3,300 600 5 C to +50 C Ambient temperature 20 C to +100 C 4 F to +212 F (no freezing or condensation) 23 F to +122 F 20 C to +70 C Storage temperature 40 C to +120 C 40 F to +248 F (no freezing or condensation) 4 F to +158 F Standard temperature 25 C 77 F 30 C 86 F 25 C 77 F 0 C to 60 C 5 C to 45 C Temperature compensation range 0 C to 50 C 32 F to +122 F 32 F to +140 F 41 F to +113 F Drive current (constant current) 1.5 mA.DC 1.0 mA.DC 1.5 mA.DC Output span voltage 4020 mV 10040 mV 6525 mV 43.522.5 mV Offset voltage 20 mV 15 mV Linearity 0.7 %FS 0.3 %FS 0.5 %FS 0.6 %FS 1.0 %FS 0.3 %FS Pressure hysteresis 0.6 %FS 0.2 %FS 0.4 %FS 1.0 %FS 0.7 %FS Offset voltage-temperature 15 %FS 5.0 %FS 3.5 %FS 10 %FS 4 characteristics Sensitivity-temperature 10 %FS 2.5 %FS 1.3 %FS 4 characteristics Notes : 1 Unless otherwise speci ed, measurements were taken with a drive current of 0.01 mA.DC and humidity ranging from 25% to 85%. 2 Please consult us if a pressure medium other than air is to be used. 3 For PS pressure sensor only 4 This is the regulation which applies within the compensation temperature range. 5 Please consult us if the intended use involves a negative pressure. Reference Data PS pressure sensor Characteristics data 1.-(1) Output characteristics 1.-(2) Offset voltage - temperature 1.-(3) Sensitivity -temperature characteristics characteristics ADP41913 ADP41913 ADP41913 Drive current : 1.0 mA.DC temperature : 30 C 86 F Drive current : 1.0 mA.DC rating 3.5 %FS Drive current : 1.0 mA.DC rating 2.5 %FS 60 4 4 3 3 50 40 2 2 30 1 1 20 0 0 1 1 10 2 2 0 0 980.7/2 5 980.7 10 0 32 30 86 60 140 0 32 30 86 60 140 Pressure(kPa) Temperature (C F) Temperature (C F) Pressure cycle range (0 to rated pressure) 6 Tested sample : ADP41913, temperature : 100 C 212 F, No. of cycle: 110 Offset voltage range Output span voltage range 3 3 2 2 Even after testing for 1 million times, the variations in the offset 1 1 voltage and output span voltage are minimal. 0 0 1 1 2 2 3 3 5 6 5 6 0510 110 0510 110 Pressure cycle(cycle) Pressure cycle(cycle) Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. 00 Aug. 2015 Output voltage (mV) Offset voltage range(%FS) Output span voltage range(%FS) Offset voltage-temperature characteristics (%FS) Sensitivity-temperature characteristics(%FS)