1 Form A 60A DQ-M RELAYS (ADQM) power latching relays FEATURES 1. Miniature and high capacity 3. High insulation Miniature relay capable of high 60 A Between contact and coil capacity control. Breakdown voltage: 4,000 V AC Size: 29.0(L)38.0(W)17.3(H) mm Surge breakdown voltage: 10,000 V 1.142(L)1.496(W).681(H) inch Nominal switching capacity: TYPICAL APPLICATIONS 60A 250V AC 2. Latching type 1. Remote control of electric power Latching type contributes to device meters RoHS compliant energy efciency. 2. Time switches Nominal operating power Protective construction: Flux-resistant 500mW (1 coil latching) type 1,000mW (2 coil latching) ORDERING INFORMATION ADQM 6 0 DQ-M relays Operating function 1: 1 coil latching (1 Form A) 2: 2 coil latching (1 Form A) Contact capacity 6: 60 A Terminal shape Nil: M4 securing screw Contact material 0: Standard contact (AgNi type) Nominal coil voltage (DC) 4H: 4.5 V, 06: 6 V, 09: 9 V, 12: 12 V, 24: 24 V TYPES Part No. Contact Nominal coil arrangement voltage 1 coil latching 2 coil latching 4.5V DC ADQM1604H ADQM2604H 6V DC ADQM16006 ADQM26006 1 Form A 9V DC ADQM16009 ADQM26009 12V DC ADQM16012 ADQM26012 24V DC ADQM16024 ADQM26024 Standard packing: Carton: 20 pcs. Case: 200 pcs. ASCTB179E 201607-T 1DQ-M (ADQM) RATING 1. Coil data 1) 1 coil latching Nominal operating Nominal coil Set voltage Reset voltage Coil resistance Nominal operating Max. applied voltage current voltage (at 20C 68F) (at 20C 68F) 10% (at 20C 68F) power (at 20C 68F) 10% (at 20C 68F) 4.5V DC 111.1mA 40.5 6V DC 83.3mA 72 80%V or less of 80%V or less of 130%V of 9V DC nominal voltage nominal voltage 55.6mA 162 500mW nominal voltage (Initial) (Initial) 12V DC 41.7mA 288 24V DC 20.8mA 1,152 2) 2 coil latching Nominal operating Nominal coil Set voltage Reset voltage Coil resistance Nominal operating Max. applied voltage current voltage (at 20C 68F) (at 20C 68F) 10% (at 20C 68F) power (at 20C 68F) 10% (at 20C 68F) 4.5V DC 221.7mA 20.3 6V DC 166.7mA 36 80%V or less of 80%V or less of 130%V of 9V DC nominal voltage nominal voltage 111.1mA 81 1,000mW nominal voltage (Initial) (Initial) 12V DC 83.3mA 144 24V DC 41.7mA 576 2. Specications Characteristics Item Specications Arrangement 1 Form A Contact Contact resistance (Initial) Max. 30 m (By voltage drop 6 V DC 1A) Contact material AgNi type Nominal switching capacity (resistive load) 60 A 250V AC Max. switching power (resistive load) 15,000 V A Max. switching voltage 250V AC Rating Max. switching current 60 A AC Nominal operating power 500mW (1 coil latching), 1,000mW (2 coil latching) 1 Min. switching capacity (Reference value)* 100mA 5 V DC Insulation resistance (Initial) Min. 1,000M (at 500V DC) Measurement at same location as Breakdown voltage section. Between open contacts 1,500 Vrms for 1min. (Detection current: 10mA.) Breakdown voltage (Initial) Between contact and coil 4,000 Vrms for 1min. (Detection current: 10mA.) Electrical Surge breakdown characteristics Between contact and coil Min. 10,000 V 2 voltage* (Initial) Set time (at 20C 68F) (Initial) Max. 20 ms (Nominal voltage applied to the coil, excluding contact bounce time.) Reset time (at 20C 68F) (Initial) Max. 20 ms (Nominal voltage applied to the coil, excluding contact bounce time.) 2 Functional Min. 200 m/s (Half-wave pulse of sine wave: 11 ms detection time: 10s.) Shock resistance 2 Destructive Min. 1,000 m/s (Half-wave pulse of sine wave: 6 ms.) Mechanical characteristics Functional 10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10s.) Vibration resistance Destructive 10 to 55 Hz at double amplitude of 2.0 mm 6 Mechanical Min. 10 (at 180 times/min.) 3 Expected life 60A 250V AC Min. 10 (resistive load, operating frequency: 15s ON, 45s OFF) Electrical 4 50A 250V AC Min. 10 (resistive load, operating frequency: 15s ON, 45s OFF) Ambient temperature: 40 to +70C 40 to +158F 3 Conditions for operation, transport and storage* Humidity: 5 to 75% R.H. (Not freezing and condensing at low temperature) Conditions Max. operating speed 1 times/min. (at rated load) Unit weight Approx. 35 g 1.23 oz Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. *2. Wave is standard shock voltage of 1.250s according to JEC-212-1981 *3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage conditions in NOTES. ASCTB179E 201607-T 2