DW (ADW1)
IEC60335-1 compliant (VDE
approved) models have been added
DW RELAYS (ADW1)
to the 1 Form A 8A, Small Polarized
Power Relays (latching type).
FEATURES TYPICAL APPLICATIONS
1. Latching type that contributes to 1. Smart meters
device energy savings 2. Industrial equipment
2. IEC60335-1 compliant, PTI 325V 3. Security equipment
(VDE approved) type available 4. Home appliances
3. Surge breakdown voltage (between 5. Various power supplies
contact and coil): 12,000 V
Reflow IEC60335-1
4. Breakdown voltage (between
compatible type compliant type
contact and coil): 5,000 V
5. Pin-in-paste construction makes
RoHS compliant
reow possible
* Protective construction: Flux-resistant type
ORDERING INFORMATION
ADW 1 W
Contact arrangement
1: 1 Form A
Operating function
1: 1 coil latching type
2: 2 coil latching type
Nominal coil voltage (DC)
03: 3V, 05: 5V, 06: 6V, 09: 9V, 12: 12V, 24: 24V
Type classification
Nil: Reflow compatible type
T: IEC60335-1 compliant type
Notes: 1. T type is non-compliant reflow soldering.
2. The suffix W on the part number is only displayed on the inner and outer packaging.
It is not displayed on the relay.
TYPES
1. Reow compatible type
Part No.
Contact arrangement Nominal coil voltage
1 coil latching type 2 coil latching type
3V DC ADW1103W ADW1203W
5V DC ADW1105W ADW1205W
6V DC ADW1106W ADW1206W
1 Form A
9V DC ADW1109W ADW1209W
12V DC ADW1112W ADW1212W
24V DC ADW1124W ADW1224W
Standard packing: Carton: 100 pcs.; Case: 500 pcs.
Note: Carton packing is standard. Tube packing type is also available. Please consult us for details.
2. IEC60335-1 compliant type
Part No.
Contact arrangement Nominal coil voltage
1 coil latching type 2 coil latching type
3V DC ADW1103TW ADW1203TW
5V DC ADW1105TW ADW1205TW
6V DC ADW1106TW ADW1206TW
1 Form A
9V DC ADW1109TW ADW1209TW
12V DC ADW1112TW ADW1212TW
24V DC ADW1124TW ADW1224TW
Standard packing: Carton: 100 pcs.; Case: 500 pcs.
Note: Carton packing is standard. Tube packing type is also available. Please consult us for details.
ASCTB8E 201210-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/
NewDW (ADW1)
RATING
1. Coil data
1) 1 coil latching type
Nominal operating
Nominal coil Set voltage Reset voltage Coil resistance Nominal operating Max. applied voltage
current
voltage (at 20C 68F) (at 20C 68F) [10%] (at 20C 68F) power (at 20C 68F)
[10%] (at 20C 68F)
3V DC 66.7mA 45
5V DC 40.0mA 125
*80%V or less of *80%V or less of
6V DC 33.3mA 180
110%V of nominal
nominal voltage nominal voltage 200mW
voltage
9V DC 22.2mA 405
(Initial) (Initial)
12V DC 16.7mA 720
24V DC 8.3mA 2,880
2) 2 coil latching type
Nominal operating
Coil resistance Nominal operating
current
Nominal coil Set voltage Reset voltage Max. applied voltage
[10%] (at 20C 68F) power
[10%] (at 20C 68F)
voltage (at 20C 68F) (at 20C 68F) (at 20C 68F)
Set coil Reset coil Set coil Reset coil Set coil Reset coil
3V DC 133.3mA 133.3mA 22.5 22.5
5V DC 80.0mA 80.0mA 62.5 62.5
*80%V or less of *80%V or less of
6V DC 66.7mA 66.7mA 90 90
110%V of nominal
nominal voltage nominal voltage 400mW 400mW
voltage
9V DC 44.4mA 44.4mA 202.5 202.5
(Initial) (Initial)
12V DC 33.3mA 33.3mA 360 360
24V DC 16.7mA 16.7mA 1,440 1,440
*Pulse drive (JIS C 5442-1996)
2. Specications
Characteristics Item Specications
Arrangement 1 Form A
Contact Contact resistance (Initial) Max. 100 m (By voltage drop 6 V DC 1A)
Contact material AgSnO2 type
Nominal switching capacity (resistive load) 8 A 250V AC
Max. switching power (resistive load) 2,000 V A
Max. switching voltage 250V AC
Rating
Max. switching current 8A AC
Nominal operating power 200mW (1 coil latching type), 400mW (2 coil latching type)
1
Min. switching capacity (Reference value)* 100mA 5 V DC
Insulation resistance (Initial) Min. 1,000M (at 500V DC, Measurement at same location as Breakdown voltage section)
Between open contacts 1,000 Vrms for 1min. (Detection current: 10mA)
Breakdown voltage
(Initial)
Between contact and coil 5,000 Vrms for 1min. (Detection current: 10mA)
Electrical
Temperature rise (coil) (at 85C 185F) Max. 35C 95F (By resistive method, contact carrying current: 8A, Coil: de-energized)
characteristics
2
Surge breakdown voltage* (Between contact and coil) 12,000 V (Initial)
Set time (at 20C 68F) Max. 15 ms (Nominal voltage applied to the coil, excluding contact bounce time)
Reset time (at 20C 68F) Max. 15 ms (Nominal voltage applied to the coil, excluding contact bounce time)
2
Functional 100 m/s (Half-wave pulse of sine wave: 11 ms; detection time: 10s)
Shock resistance
2
Destructive 1,000 m/s (Half-wave pulse of sine wave: 6 ms)
Mechanical
characteristics
Functional 10 to 55 Hz at double amplitude of 2 mm (Detection time: 10s)
Vibration resistance
Destructive 10 to 55 Hz at double amplitude of 3 mm
6
Mechanical Min. 10 (at 180 times/min.)
Expected life 4
All type: Min. 5 10 (at 8 A 250V AC, resistive load) (at 20 times/min.)
Electrical
5
IEC60335-1 compliant type: Min. 10 (at 5 A 250V AC, resistive load) (at 20 times/min.)
Temperature: 40C to +85C 40F to +185F,
3 4
Conditions for operation, transport and storage* *
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Conditions
Max. operating speed (at nominal switching capacity) 20 times/min.
Unit weight Approx. 8 g .28 oz
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of 1.250s according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
*4. Allowable range when in original packaging is 40C to +70C 40F to +158F.
ASCTB8E 201210-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/