Please contact us about TV certified products. SIL type SSR with 9mm thickness AQ8 RELAYS controls up to 3 A FEATURES 1. Slim with 9 mm .354 inch thickness 5. High dielectric strength: 3,000 Vrms The thin type (45 mm long 24 mm high (between input and output) 9 mm wide) (1.772.945.354 inch) 6. Two kinds of terminals distance are permits high density mounting. available. (5.08 mm and 7.62 mm) (.200 2. Excellent in noise resistance and .300 inch) Since the input and output are insulated 7. High reliability, long life and by the phototriac coupler, the noise on maintenance-free the output side is not fed back to the input side. TYPICAL APPLICATIONS 3. Snubber circuit integrated The snubber circuit is integrated to 1. Most suitable as drivers for small prevent malfunction caused by the rapid size AC motors, solenoids, solenoid rise of the voltage on the output side, valves and so on. such as inductive load and noise. 2. Copying equipment 4. Zero-cross and random types are 3. Air conditioners available. 4. Industrial equipment such as NC The zero-cross type generates minimal machines, sequencers, robots, etc. noise by suppressing occurrence of radio RoHS compliant frequency interference (RFI) and electro- magnetic interference (EMI). The random type features a short operation time which permits phase control. ORDERING INFORMATION AQ Load current 2 A 3 A Load voltage 2: 75 to 250 Vrms Input terminal distance C1: 5.08 mm .200 inch C2: 7.62 mm .300 inch Type ZT: Zero-cross type T: Random type Control voltage 5V DC: 4 to 6 V DC 12V DC: 9.6 to 14.4 V DC 24V DC: 21.6 to 26.4 V DC ASCTB213E 201809-T 1AQ8 TYPES Input terminals distance Input terminals distance (5.08 mm .200 inch type) (7.62 mm .300 inch type) Types Load current Load voltage Control voltage Part No. Part No. 4 to 6 V DC AQ2A2-C1-ZT5VDC AQ2A2-C2-ZT5VDC 2 A 75 to 250 Vrms 9.6 to 14.4 V DC AQ2A2-C1-ZT12VDC AQ2A2-C2-ZT12VDC 21.6 to 26.4 V DC AQ2A2-C1-ZT24VDC AQ2A2-C2-ZT24VDC Zero-cross type 4 to 6 V DC AQ3A2-C1-ZT5VDC AQ3A2-C2-ZT5VDC 3 A 75 to 250 Vrms 9.6 to 14.4 V DC AQ3A2-C1-ZT12VDC AQ3A2-C2-ZT12VDC 21.6 to 26.4 V DC AQ3A2-C1-ZT24VDC AQ3A2-C2-ZT24VDC 4 to 6 V DC AQ2A2-C1-T5VDC AQ2A2-C2-T5VDC 2 A 75 to 250 Vrms 9.6 to 14.4 V DC AQ2A2-C1-T12VDC AQ2A2-C2-T12VDC 21.6 to 26.4 V DC AQ2A2-C1-T24VDC AQ2A2-C2-T24VDC Random type 4 to 6 V DC AQ3A2-C1-T5VDC AQ3A2-C2-T5VDC 3 A 75 to 250 Vrms 9.6 to 14.4 V DC AQ3A2-C1-T12VDC AQ3A2-C2-T12VDC 21.6 to 26.4 V DC AQ3A2-C1-T24VDC AQ3A2-C2-T24VDC Standard packing: Carton 20 pcs., Case 200 pcs. RATING 1. Rating (Ambient temperature: 20C, 68F Voltage ripple on the input side: 1% or less) 1) Zero-cross type 2 A type Part No. AQ2A2-C1-ZT5VDC AQ2A2-C1-ZT12VDC AQ2A2-C1-ZT24VDC Remarks Item AQ2A2-C2-ZT5VDC AQ2A2-C2-ZT12VDC AQ2A2-C2-ZT24VDC Rated voltage 5 V DC 12 V DC 24 V DC Control voltage 4 to 6 V DC 9.6 to 14.4 V DC 21.6 to 26.4 V DC 1 Input side * Input impedance Approx. 0.18 k Approx. 0.55 k Approx. 1.4 k Drop-out voltage Min. 0.5 V Min. 1.2 V Min. 2.4 V At ambient temperature of 30C or 2 Max. load current 2 A* less Load voltage 75 to 250 Vrms Frequency 45 to 65 Hz Repetitive peak OFF voltage 600 V 3 Load side Non-repetitive surge current 30 A* In one cycle at 60 Hz Max. OFF-state leakage 5 mA (200 Vrms applied) at 60 Hz current Max. ON-state voltage drop 1.6 V at max. carrying current 4 Min. load current 50 mA* OFF state dV/dt 50 V/s At ambient temperature of 80C 3 A type Part No. AQ3A2-C1-ZT5VDC AQ3A2-C1-ZT12VDC AQ3A2-C1-ZT24VDC Remarks Item AQ3A2-C2-ZT5VDC AQ3A2-C2-ZT12VDC AQ3A2-C2-ZT24VDC Rated voltage 5 V DC 12 V DC 24 V DC Control voltage 4 to 6V DC 9.6 to 14.4V DC 21.6 to 26.4V DC 1 Input side * Input impedance Approx. 0.18 k Approx. 0.55 k Approx. 1.4 k Drop-out voltage Min. 0.5 V Min. 1.2 V Min. 2.4 V At ambient temperature of 30C or 2 Max. load current 3 A* less Load voltage 75 to 250 Vrms Frequency 45 to 65 Hz Repetitive peak OFF voltage 600 V 3 Load side Non-repetitive surge current 80 A* In one cycle at 60 Hz Max. OFF-state leakage 5 mA (200 Vrms applied) at 60 Hz current Max. ON-state voltage drop 1.6 V at max. carrying current 4 Min. load current 50 mA* OFF state dV/dt 50 V/s At ambient temperature of 80C Notes: *1. Refer to REFERENCE DATA 3. Characteristics of input current vs. input voltage. *2. Refer to REFERENCE DATA 1. Characteristics of load current vs. ambient temperature. *3. Refer to REFERENCE DATA 2. Characteristics of non-repetitive surge current vs. carrying time. *4. When the load current is less than the rated minimum load current, please refer to Cautions for Use of Solid State Relays. ASCTB213E 201809-T 2