SIL type SSR with
9mm thickness
AQ8 RELAYS
controls up to 3 A
FEATURES
1. Slim with 9 mm .354 inch thickness 5. High dielectric strength: 3,000 Vrms
The thin type (45 mm long 24 mm high (between input and output)
9 mm wide) (1.772.945.354 inch) 6. Two kinds of terminals distance are
permits high density mounting. available. (5.08 mm and 7.62 mm) (.200
2. Excellent in noise resistance and .300 inch)
Since the input and output are insulated 7. High reliability, long life and
by the phototriac coupler, the noise on maintenance-free
the output side is not fed back to the input
side.
TYPICAL APPLICATIONS
3. Snubber circuit integrated
The snubber circuit is integrated to 1. Most suitable as drivers for small
prevent malfunction caused by the rapid size AC motors, solenoids, solenoid
rise of the voltage on the output side, valves and so on.
such as inductive load and noise. 2. Copying equipment
4. Zero-cross and random types are 3. Air conditioners
available. 4. Industrial equipment such as NC
The zero-cross type generates minimal machines, sequencers, robots, etc.
noise by suppressing occurrence of radio
RoHS compliant
frequency interference (RFI) and electro-
magnetic interference (EMI).
The random type features a short
operation time which permits phase
control.
ORDERING INFORMATION
AQ
Load current
2 A
3 A
Load voltage
2: 75 to 250 Vrms
Input terminal distance
C1: 5.08 mm .200 inch
C2: 7.62 mm .300 inch
Type
ZT: Zero-cross type
T: Random type
Control voltage
5V DC: 4 to 6 V DC
12V DC: 9.6 to 14.4 V DC
24V DC: 21.6 to 26.4 V DC
ASCTB213E 201809-T
1AQ8
TYPES
Input terminals distance Input terminals distance
(5.08 mm .200 inch type) (7.62 mm .300 inch type)
Types Load current Load voltage Control voltage
Part No. Part No.
4 to 6 V DC AQ2A2-C1-ZT5VDC AQ2A2-C2-ZT5VDC
2 A 75 to 250 Vrms 9.6 to 14.4 V DC AQ2A2-C1-ZT12VDC AQ2A2-C2-ZT12VDC
21.6 to 26.4 V DC AQ2A2-C1-ZT24VDC AQ2A2-C2-ZT24VDC
Zero-cross type
4 to 6 V DC AQ3A2-C1-ZT5VDC AQ3A2-C2-ZT5VDC
3 A 75 to 250 Vrms 9.6 to 14.4 V DC AQ3A2-C1-ZT12VDC AQ3A2-C2-ZT12VDC
21.6 to 26.4 V DC AQ3A2-C1-ZT24VDC AQ3A2-C2-ZT24VDC
4 to 6 V DC AQ2A2-C1-T5VDC AQ2A2-C2-T5VDC
2 A 75 to 250 Vrms 9.6 to 14.4 V DC AQ2A2-C1-T12VDC AQ2A2-C2-T12VDC
21.6 to 26.4 V DC AQ2A2-C1-T24VDC AQ2A2-C2-T24VDC
Random type
4 to 6 V DC AQ3A2-C1-T5VDC AQ3A2-C2-T5VDC
3 A 75 to 250 Vrms 9.6 to 14.4 V DC AQ3A2-C1-T12VDC AQ3A2-C2-T12VDC
21.6 to 26.4 V DC AQ3A2-C1-T24VDC AQ3A2-C2-T24VDC
Standard packing: Carton 20 pcs., Case 200 pcs.
RATING
1. Rating (Ambient temperature: 20C, 68F; Voltage ripple on the input side: 1% or less)
1) Zero-cross type
2 A type
Part No. AQ2A2-C1-ZT5VDC AQ2A2-C1-ZT12VDC AQ2A2-C1-ZT24VDC
Remarks
Item AQ2A2-C2-ZT5VDC AQ2A2-C2-ZT12VDC AQ2A2-C2-ZT24VDC
Rated voltage 5 V DC 12 V DC 24 V DC
Control voltage 4 to 6 V DC 9.6 to 14.4 V DC 21.6 to 26.4 V DC
1
Input side *
Input impedance Approx. 0.18 k Approx. 0.55 k Approx. 1.4 k
Drop-out voltage Min. 0.5 V Min. 1.2 V Min. 2.4 V
At ambient temperature of 30C or
2
Max. load current 2 A*
less
Load voltage 75 to 250 Vrms
Frequency 45 to 65 Hz
Repetitive peak OFF voltage 600 V
3
Load side Non-repetitive surge current 30 A* In one cycle at 60 Hz
Max. OFF-state leakage
5 mA (200 Vrms applied) at 60 Hz
current
Max. ON-state voltage drop 1.6 V at max. carrying current
4
Min. load current 50 mA*
OFF state dV/dt 50 V/s At ambient temperature of 80C
3 A type
Part No. AQ3A2-C1-ZT5VDC AQ3A2-C1-ZT12VDC AQ3A2-C1-ZT24VDC
Remarks
Item AQ3A2-C2-ZT5VDC AQ3A2-C2-ZT12VDC AQ3A2-C2-ZT24VDC
Rated voltage 5 V DC 12 V DC 24 V DC
Control voltage 4 to 6V DC 9.6 to 14.4V DC 21.6 to 26.4V DC
1
Input side *
Input impedance Approx. 0.18 k Approx. 0.55 k Approx. 1.4 k
Drop-out voltage Min. 0.5 V Min. 1.2 V Min. 2.4 V
At ambient temperature of 30C or
2
Max. load current 3 A*
less
Load voltage 75 to 250 Vrms
Frequency 45 to 65 Hz
Repetitive peak OFF voltage 600 V
3
Load side Non-repetitive surge current 80 A* In one cycle at 60 Hz
Max. OFF-state leakage
5 mA (200 Vrms applied) at 60 Hz
current
Max. ON-state voltage drop 1.6 V at max. carrying current
4
Min. load current 50 mA*
OFF state dV/dt 50 V/s At ambient temperature of 80C
Notes: *1. Refer to REFERENCE DATA 3. Characteristics of input current vs. input voltage.
*2. Refer to REFERENCE DATA 1. Characteristics of load current vs. ambient temperature.
*3. Refer to REFERENCE DATA 2. Characteristics of non-repetitive surge current vs. carrying time.
*4. When the load current is less than the rated minimum load current, please refer to Cautions for Use of Solid State Relays.