JQ VDE HIGH ELECTRICAL & MECHANICAL NOISE JQ RELAYS IMMUNITY RELAY 10 FEATURES 20 .394 .787 High electrical noise immunity High switching capacity in a compact package 15.6 .614 High sensitivity: 200 mW (1a), 400 mW (1c) High surge voltage: 8,000 V between contacts and coil UL, CSA, VDE, TV, SEMKO approved Class B coil insulation type available mm inch SPECIFICATIONS Contact Characteristics Standard type High capacity type Max. operating speed 20 cpm 1 Arrangement 1 Form A, 1 Form C Initial insulation resistance* Min. 1,000 M at 500 V DC Initial contact resistance, max. 1a: 1,000 Vrms for 1 min. 100 m Between open contacts Initial (By voltage drop 6 V DC 1 A) 1c: 750 Vrms for 1 min. breakdown Contact material Silver alloy Between contacts and 2 voltage* 4,000 Vrms for 1 min. coil 5 A 125 V AC 10 A 125 V AC 1a 2 A 250 V AC 5 A 250 V AC Surge voltage between 8,000 V 3 5 A 30 V DC 5 A 30 V DC contact and coil* 4 Nominal 5 A 125 V AC 10 A 125 V AC Operate time* (at nominal voltage) Approx. 5 ms switching N.O. 2 A 250 V AC 5 A 250 V AC 4 Release time* Approx. 2 ms capacity 3 A 30 V AC 5 A 30 V DC (at nominal voltage)(without diode) 1c 2 A 125 V AC 3 A 125 V AC 5 Temperature rise* Max. 45C N.C. 1 A 250 V AC 2 A 250 V AC Rating 6 2 Functional* Min. 294 m/s 30 G Shock 1 A 30 V DC 1 A 30 V DC (resistive) 7 2 resistance Destructive* Min. 980 m/s 100 G 1a 625 VA, 150 W 1,250 VA, 150 W Max. 2 98 m/s 10 G , 10 to 55 Hz switching N.O. 625 VA, 90 W 1,250 V AC, 150 W 8 Functional* 1c at double amplitude of 1.6 mm Vibration power N.C. 250 VA, 30 W 500 V AC, 30 W 2 resistance 117.6 m/s 12 G , 10 to 55 Hz Destructive Max. switching voltage 250 V AC, 110 V DC (0.3A) at double amplitude of 2.0 mm Max. switching current N.O.: 5 A N.C.: 2 A N.O.: 10 A N.C.: 3 A Conditions for operation, Ambient 40C to +85C 1 9 10 Min. switching capacity 100 mA, 5 V DC transport and storage* temp.* 40F to +185F (Not freezing and Expected mechanical life 7 10 condensing at low Humidity 5 to 85% R.H. (at 180 cpm)(min. operations) temperature) Expected electrical life (min. operations) Unit weight Approx. 7 g .25 oz Type Switching capacity No. of operations 1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the 4 5 A 125 V AC 510 actual load. 5 3 A 125 V AC 210 1a 5 Remarks 2 A 250 V AC 210 * Specications will vary with foreign standards certication ratings. 5 5 A 30 V DC 10 1 * Measurement at same location as Initial breakdown voltage section 4 2 5 A 125 V AC 510 * Detection current: 10 mA Standard type 5 3 N.O. 2 A 250 V AC 210 * Wave is standard shock voltage of 1.2 50 s according to JEC-212-1981 4 5 * Excluding contact bounce time 3 A 30 V DC 10 5 1c * Measured conditions 5 2 A 125 V AC 210 Resistive, nominal voltage applied to the coil. 5 N.C. 1 A 250 V AC 210 Standard type Contact carrying current: 5 A, at 70C 158F 5 1 A 30 V DC 10 Resistive, nominal voltage applied to the coil. 4 High capacity type 10 A 125 V AC 510 Contact carrying current: 10 A, at 70C 158F 4 1a 5 A 250 V AC 510 6 * Half-wave pulse of sine wave: 11ms detection time: 10 s 5 5 A 30 V DC 10 7 * Half-wave pulse of sine wave: 6ms 8 4 * Detection time: 10 s 10 A 125 V AC 510 9 High capacity * Refer to 6. Conditions for operation, transport and storage mentioned in 4 N.O. 5 A 250 V AC 510 type AMBIENT ENVIRONMENT 5 5 A 30 V DC 10 10 * When using relays in a high ambient temperature, consider the pick-up voltage 1c 5 3 A 125 V AC 210 rise due to the high temperature (a rise of approx. 0.4% V for each 1C 33.8F 5 with 20C 68F as a reference) and use a coil impressed voltage that is within N.C. 2 A 250 V AC 210 5 the maximum allowable voltage range. 1 A 30 V DC 10 Coil (at 20C 68F) Nominal operating power 1a: 200 mW 1c: 400 mW All Rights Reserved COPYRIGHT Matsushita Electric Works, Ltd. JQ TYPICAL APPLICATIONS Air conditioners Refrigerators Microwave ovens Heaters ORDERING INFORMATION Ex. JQ 1a P B 12 V F Contact Contact capacity Coil insulation class Coil voltage (DC) Environmental support arrangement 1a: 1 Form A Nil: Standard Nil: Class E coil insulation 5, 6, 9, 12, 18, 24, 48* V F: RoHS Directive conforming type (AgSnO2 type) 1: 1 Form C P: High capacity B: Class B coil insulation Nil: RoHS Directive non-conforming type (AgCdO type) UL/CSA, VDE, SEMKO approved type is standard. * Available only for 1 Form C type TYPES AND COIL DATA at 20C 68F Pick-up Drop-out Nominal Nominal Nominal Coil resistance, Max. allowable Part No. voltage, V DC voltage, V DC operating operating voltage, V DC (10%) voltage, V DC (min.) (min.) current, mA power, mW JQ1a-5V (-F) 5 3.75 0.25 40 125 JQ1a-6V (-F) 6 4.5 0.3 33.3 180 180% of JQ1a-9V (-F) 9 6.75 0.45 22.2 405 200 nominal voltage JQ1a-12V (-F) 12 9 0.6 16.7 720 (at 20C 68F) JQ1a-18V (-F) 18 13.5 0.9 11.1 1,620 JQ1a-24V (-F) 24 18 1.2 8.3 2,880 JQ1aP-5V (-F) 5 4 0.25 40 125 JQ1aP-6V (-F) 6 4.8 0.3 33.3 180 130% of JQ1aP-9V (-F) 9 7.2 0.45 22.2 405 200 nominal voltage JQ1aP-12V (-F) 12 9.6 0.6 16.7 720 (at 85C 185F) JQ1aP-18V (-F) 18 14.4 0.9 11.1 1,620 JQ1aP-24V (-F) 24 19.2 1.2 8.3 2,880 JQ1-5V (-F) 5 3.75 0.25 80 62.5 JQ1-6V (-F) 6 4.5 0.3 66.7 90 JQ1-9V (-F) 9 6.75 0.45 44.4 202.5 150% of JQ1-12V (-F) 12 9 0.6 33.3 400 360 nominal voltage (at 20C 68F) JQ1-18V (-F) 18 13.5 0.9 22.2 810 JQ1-24V (-F) 24 18 1.2 16.7 1,440 JQ1-48V (-F) 48 36 2.4 8.3 5,760 JQ1P-5V (-F) 5 4 0.25 80 62.5 JQ1P-6V (-F) 6 4.8 0.3 66.7 90 JQ1P-9V (-F) 9 7.2 0.45 44.4 202.5 110% of JQ1P-12V (-F) 12 9.6 0.6 33.3 400 360 nominal voltage (at 85C 185F) JQ1P-18V (-F) 18 14.4 0.9 22.2 810 JQ1P-24V (-F) 24 19.2 1.2 16.7 1,440 JQ1P-48V (-F) 48 38.4 2.4 8.3 5,760 All Rights Reserved COPYRIGHT Matsushita Electric Works, Ltd. 1 Form C 1 Form A High capacity type Standard type High capacity type Standard type