VDE Partly to Be Discontinued: 1a/1c 5A/10A small power 10A type (Made in Thailand) JQ RELAYS relays Last time buy: September 30, 2016 FEATURES TYPICAL APPLICATIONS High electrical noise immunity Air conditioners High switching capacity in a compact Refrigerators package Microwave ovens High sensitivity: 200 mW (1a), Heaters 400 mW (1c) High surge voltage: 8,000 V between contacts and coil UL, CSA, VDE, SEMKO approved and TV available Class B coil insulation type also RoHS compliant available. ORDERING INFORMATION JQ F Contact arrangement 1a: 1 Form A 1 : 1 Form C Contact capacity Nil: Standard (5A) P: High capacity (10A) Coil insulation class Nil: Class E coil insulation B: Class B coil insulation (UL) Nominal coil voltage (DC) 5V, 6V, 9V, 12V, 18V, 24V, 48V* Contact material F: AgSnO2 type Certified by UL, CSA, VDE and SEMKO Note: *Available only for 1 Form C type TYPES 1) Standard type Standard type High capacity type Nominal coil voltage 1 Form A 1 Form C 1 Form A 1 Form C Part No. Part No. Part No. Part No. 5V DC JQ1a-5V-F JQ1-5V-F JQ1aP-5V-F JQ1P-5V-F 6V DC JQ1a-6V-F JQ1-6V-F JQ1aP-6V-F JQ1P-6V-F 9V DC JQ1a-9V-F JQ1-9V-F JQ1aP-9V-F JQ1P-9V-F 12V DC JQ1a-12V-F JQ1-12V-F JQ1aP-12V-F JQ1P-12V-F 18V DC JQ1a-18V-F JQ1-18V-F JQ1aP-18V-F JQ1P-18V-F 24V DC JQ1a-24V-F JQ1-24V-F JQ1aP-24V-F JQ1P-24V-F 48V DC JQ1-48V-F JQ1P-48V-F Standard packing: Carton 100 pcs., Case 500 pcs. ASCTB185E 201509-T 1Partly to Be Discontinued: 10A type (Made in Thailand) Last time buy: September 30, 2016 JQ RATING 1. Coil data Drop-out Nominal operating Nominal operating Contact Nominal coil Pick-up voltage Coil resistance voltage current power Max. applied voltage arrangement voltage (at 20C 68F) 10% (at 20C 68F) (at 20C 68F) 10% (at 20C 68F) (at 20C 68F) 5V DC 40.0mA 125 Standard type: 180% of nominal voltage 6V DC 75%V or less of 33.3mA 180 (at 20C 68F) nominal voltage (Initial) 5%V or more of 9V DC 22.2mA 405 1 Form A nominal voltage 200mW 130% of nominal voltage 12V DC 16.7mA 720 High capacity type: (Initial) (at 70C 158F) 18V DC 80%V or less of 11.1mA 1,620 When using relays at nominal voltage (Initial) 85C 185F, see Notes*4 24V DC 8.3mA 2,880 5V DC 80 mA 62.5 Standard type: 150% of nominal voltage 6V DC 66.7mA 90 75%V or less of (at 20C 68F) 9V DC 44.4mA 202.5 nominal voltage (Initial) 5%V or more of 1 Form C 12V DC nominal voltage 33.3mA 360 400mW 110% of nominal voltage High capacity type: (Initial) (at 70C 158F) 18V DC 22.2mA 810 80%V or less of When using relays at 24V DC 16.7mA 1,440 nominal voltage (Initial) 85C 185F, see Notes*4 48V DC 8.3mA 5,760 2. Specications Specications Characteristics Item Standard type High capacity type Arrangement 1 Form A 1 Form C 1 Form A 1 Form C Contact Contact resistance (Initial) Max. 100m (By voltage drop 6 V DC 1 A) Contact material AgSnO2 type N.O. side: N.O. side: 5 A 125 V AC, 10 A 125 V AC, 2 A 250 V AC, 5 A 250 V AC, 5 A 125 V AC, 10 A 125 V AC, 3 A 30 V AC 5 A 30 V AC Nominal switching capacity (resistive load) 2 A 250 V AC, 5 A 250 V AC, N.C. side: N.C. side: 5 A 30 V DC 5 A 30 V DC 2 A 125 V AC, 3 A 125 V AC, 1 A 250 V AC, 2 A 250 V AC, 1 A 30 V DC 1 A 30 V DC Rating N.O. side: N.O. side: 625 VA, 90 W 1,250 VA, 150 W Max. switching power (resistive load) 625 VA, 150 W 1,250 V AC, 150 W N.C. side: N.C. side: 250 VA, 30 W 500 V AC, 30 W Max. switching voltage 250 V AC, 110 V DC (0.3A) Max. switching current N.O.: 5 A, N.C.: 2 A N.O.: 10 A, N.C.: 3 A Nominal operating power 200 mW 400 mW 200 mW 400 mW 1 Min. switching capacity (reference value)* 100 mA, 5 V DC Insulation resistance (Initial) Min. 1,000 M (at 500 V DC) Measurement at same location as Breakdown voltage section. Between open contacts 1,000 Vrms for 1 min. 750 Vrms for 1 min. 1,000 Vrms for 1 min. 750 Vrms for 1 min. Breakdown voltage (Initial) Between contact and coil 4,000 Vrms for 1 min. (Detection current: 10 mA) Max. 45C 113F Max. 45C 113F (By resistive method, nominal coil voltage (By resistive method, nominal coil voltage Temperature rise (coil) applied to the coil contact carrying current: applied to the coil contact carrying current: Electrical 5A, at 70C 158F) 10A, at 70C 158F) characteristics 2 Surge breakdown voltage* 8,000 V (Between contact and coil) (Initial) Operate time (at nominal voltage) (at 20C 68F) Max. 20 ms (excluding contact bounce time.) (Initial) Release time (at nominal voltage) (at 20C 68F) Max. 10 ms (excluding contact bounce time) (Without diode) (Initial) 2 Functional 294 m/s (Half-wave pulse of sine wave: 11 ms detection time: 10s.) Shock resistance 2 Destructive 980 m/s (Half-wave pulse of sine wave: 6 ms.) Mechanical characteristics Functional 10 to 55 Hz at double amplitude of 1.6 mm (Detection time: 10s.) Vibration resistance Destructive 10 to 55 Hz at double amplitude of 2.0 mm 7 Expected life Mechanical (at 180 times/min.) Min. 10 Ambient temperature: 40C to +70C 40F to +158F (class E insulation), 3 4 Conditions for operation, transport and storage* 40C to +85C 40F to +185F* (class B insulation) Conditions Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) Max. operating speed 20 times/min. (at nominal switching capacity) Unit weight Approx. 7 g .25 oz * Specications will vary with foreign standards certication ratings. Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. *2. Wave is standard shock voltage of 1.250s according to JEC-212-1981 *3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage conditions in NOTES. *4. When using relays in a high ambient temperature, consider the pick-up voltage rise due to the high temperature (a rise of approx. 0.4% V for each 1C 33.8F with 20C 68F as a reference) and use a coil impressed voltage that is within the maximum applied voltage range. ASCTB185E 201509-T 2