JQ VDE
1a/1c 5A/10A small power
JQ RELAYS
relays
FEATURES TYPICAL APPLICATIONS
High electrical noise immunity Air conditioners
High switching capacity in a compact Refrigerators
package Microwave ovens
High sensitivity: 200 mW (1a), Heaters
400 mW (1c)
High surge voltage: 8,000 V between
contacts and coil
UL, CSA, VDE, SEMKO approved and
TV available
Class B coil insulation type also
RoHS compliant
available.
ORDERING INFORMATION
JQ F
Contact arrangement
1a: 1 Form A
1 : 1 Form C
Contact capacity
Nil: Standard (5A)
P: High capacity (10A)
Coil insulation class
Nil: Class E coil insulation
B: Class B coil insulation (UL)
Nominal coil voltage (DC)
5V, 6V, 9V, 12V, 18V, 24V, 48V*
Contact material
F: AgSnO2 type
Certified by UL, CSA, VDE and SEMKO
Note: *Available only for 1 Form C type
TYPES
1) Standard type
Standard type High capacity type
Nominal coil voltage 1 Form A 1 Form C 1 Form A 1 Form C
Part No. Part No. Part No. Part No.
5V DC JQ1a-5V-F JQ1-5V-F JQ1aP-5V-F JQ1P-5V-F
6V DC JQ1a-6V-F JQ1-6V-F JQ1aP-6V-F JQ1P-6V-F
9V DC JQ1a-9V-F JQ1-9V-F JQ1aP-9V-F JQ1P-9V-F
12V DC JQ1a-12V-F JQ1-12V-F JQ1aP-12V-F JQ1P-12V-F
18V DC JQ1a-18V-F JQ1-18V-F JQ1aP-18V-F JQ1P-18V-F
24V DC JQ1a-24V-F JQ1-24V-F JQ1aP-24V-F JQ1P-24V-F
48V DC JQ1-48V-F JQ1P-48V-F
Standard packing: Carton 100 pcs., Case 500 pcs.
ASCTB185E 201202-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/JQ
RATING
1. Coil data
Drop-out Nominal operating Nominal operating
Contact Nominal coil Pick-up voltage Coil resistance
voltage current power Max. applied voltage
arrangement voltage (at 20C 68F) [10%] (at 20C 68F)
(at 20C 68F) [10%] (at 20C 68F) (at 20C 68F)
5V DC 40.0mA 125
Standard type: 180% of nominal voltage
6V DC 75%V or less of 33.3mA 180 (at 20C 68F)
nominal voltage (Initial) 5%V or more of
9V DC 22.2mA 405
1 Form A nominal voltage 200mW 130% of nominal voltage
12V DC 16.7mA 720
High capacity type: (Initial) (at 70C 158F)
18V DC 80%V or less of 11.1mA 1,620 [When using relays at
nominal voltage (Initial) 85C 185F, see Notes*4]
24V DC 8.3mA 2,880
5V DC 80 mA 62.5
Standard type: 150% of nominal voltage
6V DC 66.7mA 90
75%V or less of (at 20C 68F)
9V DC 44.4mA 202.5
nominal voltage (Initial) 5%V or more of
1 Form C 12V DC nominal voltage 33.3mA 360 400mW 110% of nominal voltage
High capacity type: (Initial) (at 70C 158F)
18V DC 22.2mA 810
80%V or less of [When using relays at
24V DC 16.7mA 1,440
nominal voltage (Initial) 85C 185F, see Notes*4]
48V DC 8.3mA 5,760
2. Specications
Specications
Characteristics Item
Standard type High capacity type
Arrangement 1 Form A 1 Form C 1 Form A 1 Form C
Contact Contact resistance (Initial) Max. 100m (By voltage drop 6 V DC 1 A)
Contact material AgSnO2 type
N.O. side: N.O. side:
5 A 125 V AC, 10 A 125 V AC,
2 A 250 V AC, 5 A 250 V AC,
5 A 125 V AC, 10 A 125 V AC,
3 A 30 V AC 5 A 30 V AC
Nominal switching capacity (resistive load) 2 A 250 V AC, 5 A 250 V AC,
N.C. side: N.C. side:
5 A 30 V DC 5 A 30 V DC
2 A 125 V AC, 3 A 125 V AC,
1 A 250 V AC, 2 A 250 V AC,
1 A 30 V DC 1 A 30 V DC
Rating N.O. side: N.O. side:
625 VA, 90 W 1,250 VA, 150 W
Max. switching power (resistive load) 625 VA, 150 W 1,250 V AC, 150 W
N.C. side: N.C. side:
250 VA, 30 W 500 V AC, 30 W
Max. switching voltage 250 V AC, 110 V DC (0.3A)
Max. switching current N.O.: 5 A, N.C.: 2 A N.O.: 10 A, N.C.: 3 A
Nominal operating power 200 mW 400 mW 200 mW 400 mW
1
Min. switching capacity (reference value)* 100 mA, 5 V DC
Insulation resistance (Initial) Min. 1,000 M (at 500 V DC) Measurement at same location as Breakdown voltage section.
Between open contacts 1,000 Vrms for 1 min. 750 Vrms for 1 min. 1,000 Vrms for 1 min. 750 Vrms for 1 min.
Breakdown voltage
(Initial)
Between contact and coil 4,000 Vrms for 1 min. (Detection current: 10 mA)
Max. 45C 113F Max. 45C 113F
(By resistive method, nominal coil voltage (By resistive method, nominal coil voltage
Temperature rise (coil)
applied to the coil; contact carrying current: applied to the coil; contact carrying current:
Electrical
5A, at 70C 158F) 10A, at 70C 158F)
characteristics
2
Surge breakdown voltage*
8,000 V
(Between contact and coil) (Initial)
Operate time (at nominal voltage) (at 20C 68F)
Max. 20 ms (excluding contact bounce time.)
(Initial)
Release time (at nominal voltage) (at 20C 68F)
Max. 10 ms (excluding contact bounce time) (Without diode)
(Initial)
2
Functional 294 m/s (Half-wave pulse of sine wave: 11 ms; detection time: 10s.)
Shock resistance
2
Destructive 980 m/s (Half-wave pulse of sine wave: 6 ms.)
Mechanical
characteristics
Functional 10 to 55 Hz at double amplitude of 1.6 mm (Detection time: 10s.)
Vibration resistance
Destructive 10 to 55 Hz at double amplitude of 2.0 mm
7
Expected life Mechanical (at 180 times/min.) Min. 10
Ambient temperature: 40C to +70C 40F to +158F (class E insulation),
3 4
Conditions for operation, transport and storage* 40C to +85C 40F to +185F* (class B insulation)
Conditions
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Max. operating speed 20 times/min. (at nominal switching capacity)
Unit weight Approx. 7 g .25 oz
* Specications will vary with foreign standards certication ratings.
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of 1.250s according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
*4. When using relays in a high ambient temperature, consider the pick-up voltage rise due to the high temperature (a rise of approx. 0.4% V for each 1C 33.8F with
20C 68F as a reference) and use a coil impressed voltage that is within the maximum applied voltage range.
ASCTB185E 201202-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/