JT-V
Surge withstand voltage:
6kV
JT-V RELAYS
1a/1c 30A power relays
FEATURES TYPICAL APPLICATIONS
Surge withstand voltage: 6,000 V Oven
High switching capacity 30 A for Heating & ventilation
1 Form A Home appliance
2 contact arrangements 1 Form A
or 1 Form C
TMP types available
UL/C-UL recognized
PCB type
Class F types standard
TMP type
RoHS compliant
ORDERING INFORMATION
JTV
Contact arrangement
1a: 1 Form A
1: 1 Form C
Protective construction
S: Sealed type
G: Dust cover type
Mounting classification
TMP: TMP type
PA: PCB type
Nominal coil voltage, DC
12V, 18V, 24V, 48V
Notes: 1. Certified by UL/C-UL
2. 5 V, 6 V, 9 V DC types are also available. Please contact us for details.
TYPES
1. 1 Form A Dust cover type
Part No.
Nominal coil voltage
PCB type TMP type
12V DC JTV1aG-PA-12V JTV1aG-TMP-12V
18V DC JTV1aG-PA-18V JTV1aG-TMP-18V
24V DC JTV1aG-PA-24V JTV1aG-TMP-24V
48V DC JTV1aG-PA-48V JTV1aG-TMP-48V
Standard packing: PCB type: Carton: 50 pcs.; Case: 500 pcs.
TMP type: Carton: 50 pcs.; Case: 300 pcs.
2. 1 Form C Dust cover type
Part No.
Nominal coil voltage
PCB type TMP type
12V DC JTV1G-PA-12V JTV1G-TMP-12V
18V DC JTV1G-PA-18V JTV1G-TMP-18V
24V DC JTV1G-PA-24V JTV1G-TMP-24V
48V DC JTV1G-PA-48V JTV1G-TMP-48V
Standard packing: PCB type: Carton: 50 pcs.; Case: 500 pcs.
TMP type: Carton: 50 pcs.; Case: 300 pcs.
ASCTB188E 201202-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/JT-V
3. 1 Form A Sealed type
Part No.
Nominal coil voltage
PCB type TMP type
12V DC JTV1aS-PA-12V JTV1aS-TMP-12V
18V DC JTV1aS-PA-18V JTV1aS-TMP-18V
24V DC JTV1aS-PA-24V JTV1aS-TMP-24V
48V DC JTV1aS-PA-48V JTV1aS-TMP-48V
Standard packing: PCB type: Carton: 50 pcs.; Case: 500 pcs.
TMP type: Carton: 50 pcs.; Case: 300 pcs.
4. 1 Form C Sealed type
Part No.
Nominal coil voltage
PCB type TMP type
12V DC JTV1S-PA-12V JTV1S-TMP-12V
18V DC JTV1S-PA-18V JTV1S-TMP-18V
24V DC JTV1S-PA-24V JTV1S-TMP-24V
48V DC JTV1S-PA-48V JTV1S-TMP-48V
Standard packing: PCB type: Carton: 50 pcs.; Case: 500 pcs.
TMP type: Carton: 50 pcs.; Case: 300 pcs.
RATING
1. Coil data
Nominal operating
Nominal coil Pick-up voltage Drop-out voltage Coil resistance Nominal operating Max. applied voltage
current
voltage (at 20C 68F) (at 20C 68F) [10%] (at 20C 68F) power (at 20C 68F)
[10%] (at 20C 68F)
12V DC 83.3mA 144
75%V or less of 10%V or more of
18V DC 55.6mA 324
120%V of
nominal voltage nominal voltage 1,000mW
nominal voltage
24V DC 41.7mA 576
(Initial) (Initial)
48V DC 20.8mA 2,304
2. Specications
Characteristics Item Specications
Contact material AgSnO2 type
Contact Arrangement 1 Form A 1 Form C
Contact resistance (Initial) Max. 50 m (By voltage drop 6 V DC 1A)
Nominal switching capacity (resistive load) 20A 277V AC N.C.: 10A 277V AC, N.O.: 20A 277V AC
Max. switching power (resistive load) 8,310VA (30A 277V AC) N.C.: 2,770VA, N.O.: 5,540VA
Max. switching voltage 277V AC
Rating
Max. switching current 30A N.C.: 10A, N.O.: 20A
Nominal operating power Approx. 1,000mW
1
Min. switching capacity (reference value)* 100mA, 5V DC
Insulation resistance (Initial) Min. 100M (at 500V DC) Measurement at same location as Breakdown voltage section.
Between open contacts 1,200 Vrms for 1 min. (Detection current: 10 mA)
Breakdown voltage
(Initial)
Between contact and coil 3,500 Vrms for 1 min. (Detection current: 10 mA)
Electrical
2
Surge breakdown voltage*
characteristics
6,000 V
(Between contact and coil) (Initial)
Operate time (at nominal voltage) (at 20C 68F) Max. 15 ms (excluding contact bounce time.)
Release time (at nominal voltage) (at 20C 68F) Max. 10 ms (excluding contact bounce time) (Without diode)
2
Functional Min. 98 m/s (Half-wave pulse of sine wave: 11 ms; detection time: 10s.)
Shock resistance
2
Destructive Min. 980 m/s (Half-wave pulse of sine wave: 6 ms.)
Mechanical
characteristics
Functional 10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10s.)
Vibration resistance
Destructive 10 to 55 Hz at double amplitude of 2 mm
7
Mechanical Min. 110
5
N.O.: Min. 110
Expected life
(20A 277V AC at resistive load)
3 5
Electrical (at 20 times/min.)* Min. 110 (20A 277V AC at resistive load)
5
N.C.: Min. 110
(10A 277V AC at resistive load)
Ambient temperature: 55C to +85C 67F to +185F,
4
Conditions for operation, transport and storage*
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Conditions
Max. operating speed 20 times/min. (at nominal switching capacity)
PCB type: Approx. 25 g .88 oz
Unit weight
TMP type: Approx. 30 g 1.06 oz
* Specications will vary with foreign standards certication ratings.
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of 1.250s according to JEC-212-1981
*3. In order to obtain the full rated life cycles, the relay should be properly vented by removing the vent nib. More detail, please look at caution for NOTES.
*4. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
ASCTB188E 201202-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/