JT-V Surge withstand voltage: 6kV JT-V RELAYS 1a/1c 30A power relays FEATURES TYPICAL APPLICATIONS Surge withstand voltage: 6,000 V Oven High switching capacity 30 A for Heating & ventilation 1 Form A Home appliance 2 contact arrangements 1 Form A or 1 Form C TMP types available UL/C-UL recognized PCB type Class F types standard TMP type RoHS compliant ORDERING INFORMATION JTV Contact arrangement 1a: 1 Form A 1: 1 Form C Protective construction S: Sealed type G: Dust cover type Mounting classification TMP: TMP type PA: PCB type Nominal coil voltage, DC 12V, 18V, 24V, 48V Notes: 1. Certified by UL/C-UL 2. 5 V, 6 V, 9 V DC types are also available. Please contact us for details. TYPES 1. 1 Form A Dust cover type Part No. Nominal coil voltage PCB type TMP type 12V DC JTV1aG-PA-12V JTV1aG-TMP-12V 18V DC JTV1aG-PA-18V JTV1aG-TMP-18V 24V DC JTV1aG-PA-24V JTV1aG-TMP-24V 48V DC JTV1aG-PA-48V JTV1aG-TMP-48V Standard packing: PCB type: Carton: 50 pcs. Case: 500 pcs. TMP type: Carton: 50 pcs. Case: 300 pcs. 2. 1 Form C Dust cover type Part No. Nominal coil voltage PCB type TMP type 12V DC JTV1G-PA-12V JTV1G-TMP-12V 18V DC JTV1G-PA-18V JTV1G-TMP-18V 24V DC JTV1G-PA-24V JTV1G-TMP-24V 48V DC JTV1G-PA-48V JTV1G-TMP-48V Standard packing: PCB type: Carton: 50 pcs. Case: 500 pcs. TMP type: Carton: 50 pcs. Case: 300 pcs. ASCTB188E 201202-T Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/JT-V 3. 1 Form A Sealed type Part No. Nominal coil voltage PCB type TMP type 12V DC JTV1aS-PA-12V JTV1aS-TMP-12V 18V DC JTV1aS-PA-18V JTV1aS-TMP-18V 24V DC JTV1aS-PA-24V JTV1aS-TMP-24V 48V DC JTV1aS-PA-48V JTV1aS-TMP-48V Standard packing: PCB type: Carton: 50 pcs. Case: 500 pcs. TMP type: Carton: 50 pcs. Case: 300 pcs. 4. 1 Form C Sealed type Part No. Nominal coil voltage PCB type TMP type 12V DC JTV1S-PA-12V JTV1S-TMP-12V 18V DC JTV1S-PA-18V JTV1S-TMP-18V 24V DC JTV1S-PA-24V JTV1S-TMP-24V 48V DC JTV1S-PA-48V JTV1S-TMP-48V Standard packing: PCB type: Carton: 50 pcs. Case: 500 pcs. TMP type: Carton: 50 pcs. Case: 300 pcs. RATING 1. Coil data Nominal operating Nominal coil Pick-up voltage Drop-out voltage Coil resistance Nominal operating Max. applied voltage current voltage (at 20C 68F) (at 20C 68F) 10% (at 20C 68F) power (at 20C 68F) 10% (at 20C 68F) 12V DC 83.3mA 144 75%V or less of 10%V or more of 18V DC 55.6mA 324 120%V of nominal voltage nominal voltage 1,000mW nominal voltage 24V DC 41.7mA 576 (Initial) (Initial) 48V DC 20.8mA 2,304 2. Specications Characteristics Item Specications Contact material AgSnO2 type Contact Arrangement 1 Form A 1 Form C Contact resistance (Initial) Max. 50 m (By voltage drop 6 V DC 1A) Nominal switching capacity (resistive load) 20A 277V AC N.C.: 10A 277V AC, N.O.: 20A 277V AC Max. switching power (resistive load) 8,310VA (30A 277V AC) N.C.: 2,770VA, N.O.: 5,540VA Max. switching voltage 277V AC Rating Max. switching current 30A N.C.: 10A, N.O.: 20A Nominal operating power Approx. 1,000mW 1 Min. switching capacity (reference value)* 100mA, 5V DC Insulation resistance (Initial) Min. 100M (at 500V DC) Measurement at same location as Breakdown voltage section. Between open contacts 1,200 Vrms for 1 min. (Detection current: 10 mA) Breakdown voltage (Initial) Between contact and coil 3,500 Vrms for 1 min. (Detection current: 10 mA) Electrical 2 Surge breakdown voltage* characteristics 6,000 V (Between contact and coil) (Initial) Operate time (at nominal voltage) (at 20C 68F) Max. 15 ms (excluding contact bounce time.) Release time (at nominal voltage) (at 20C 68F) Max. 10 ms (excluding contact bounce time) (Without diode) 2 Functional Min. 98 m/s (Half-wave pulse of sine wave: 11 ms detection time: 10s.) Shock resistance 2 Destructive Min. 980 m/s (Half-wave pulse of sine wave: 6 ms.) Mechanical characteristics Functional 10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10s.) Vibration resistance Destructive 10 to 55 Hz at double amplitude of 2 mm 7 Mechanical Min. 110 5 N.O.: Min. 110 Expected life (20A 277V AC at resistive load) 3 5 Electrical (at 20 times/min.)* Min. 110 (20A 277V AC at resistive load) 5 N.C.: Min. 110 (10A 277V AC at resistive load) Ambient temperature: 55C to +85C 67F to +185F, 4 Conditions for operation, transport and storage* Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) Conditions Max. operating speed 20 times/min. (at nominal switching capacity) PCB type: Approx. 25 g .88 oz Unit weight TMP type: Approx. 30 g 1.06 oz * Specications will vary with foreign standards certication ratings. Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. *2. Wave is standard shock voltage of 1.250s according to JEC-212-1981 *3. In order to obtain the full rated life cycles, the relay should be properly vented by removing the vent nib. More detail, please look at caution for NOTES. *4. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage conditions in NOTES. ASCTB188E 201202-T Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/