Mini-Com TX6 PLUS UTP Jack Module SPECIFICATION SHEET specifications Category 6/Class E, 8-position, UTP jack module shall terminate solid, 4-pair, 24 22 AWG, 100 ohm unshielded twisted pair cable and shall not require use of a punchdown tool. UTP jack modules shall use a forward motion termination method to optimize performance by maintaining cable pair TX6 PLUS UTP geometry while eliminating conductor untwist. The termination Copper Cabling System cap shall be color-coded white to designate Category 6 Mini-Com TX6 PLUS performance and shall include a universal label coded for UTP Jack Module T568A and T568B wiring schemes. Jack module: CJ688TPIW* TX6000 UTP Copper Cable technical information Plenum: PUP6004** Riser: PUR6004** Category 6/Class E channel Exceeds channel requirements of ANSI/TIA-568-C.2 Category 6 LSZH: PUL6004** and component performance: and ISO 11801 Class E standards at swept frequencies CM: PUC6004** 1 to 250 MHz TX6 PLUS UTP Patch Cords Exceeds component requirements of ANSI/TIA-568-C.2 Category 6 CM (foot lengths): UTPSP Y and ISO 11801 Class E standards at swept frequencies CM (meter lengths): UTPSP MY 1 to 250 MHz LSZH FCC and ANSI compliance: Meets all applicable ANSI/TIA-968-A requirements contacts plated (meter lengths): UTPSPL MY with 50 microinches of gold for superior performance Mini-Com Angled PoE compliance: Meets requirements of IEEE 802.3af and IEEE 802.3at for Modular Patch Panels PoE applications 24-port, 1 RU: CPPLA24WBLY IEC compliance: Meets IEC 60603-7 48-port, 2 RU: CPPLA48WBLY RoHS compliance: Compliant Mini-Com Flat Modular Patch Panels UL rated: UL 1863 approved 24-port, 1 RU: CPPL24WBLY Conductor termination range: Wire cap compatible with 24 22 AWG solid cable with conductor 48-port, 2 RU: CPPL48WBLY insulation diameters of 0.035 in. to 0.048 in. and overall cable O.D. 0.200 in. to 0.330 in. For additional modular and punchdown patch panels, visit www.panduit.com. Tools and Accessories key features and benefits Jack module termination tool: CGJT 100% performance tested Confidence that each jack module will deliver the critical Wire snipping tool: CWST electrical performance requirements Wire snipping tool: CJAST Utilizes enhanced Optimizes performance by eliminating conductor untwist and Clear dust cap: MDC-C Giga-TX Technology reduces installation time and expense Block out device: PSL-DCJB- Phone icons: CIPIW-C+ Improved termination cap Conductor retention slots simplify jack module termination Data icons: CIDIW-C+ Modular UTP jack modules snap in and out of all Mini-Com Faceplates, Modular Patch Panels and Surface Mount Boxes for easy moves, *To designate color other than IW (Off White), adds and changes replace IW suffix with EI (Electric Ivory), IG (International Gray), WH (White), True strain relief Controls cable bend radius for long term installed performance AW (Arctic White), BL (Black), BU (Blue), RD (Red), YL (Yellow), GR (Green), Individually serialized Marked with quality control number for future traceability OR (Orange), or VL (Violet). RJ45 interface Industry standard interface provides a quick and easy plug and **To designate color, add suffix BU (Blue) play connection to RJ45 patch cords backwards compatible or WH (White). For additional cable colors, contact customer service. Identification Can be clearly identified with optional labels and icons for port identification For lengths 1 to 20 feet (one foot increments) and 25, 30, 35, 40 feet, change the length Termination tools (optional) CGJT termination tool ensures conductors are fully terminated designation in the part number to the desired by utilizing a smooth forward motion without impact on critical length. For standard cable colors other than internal components for maximum reliability Off White, add suffix BL (Black), BU (Blue), RD (Red), YL (Yellow), GR (Green), OR (Orange) Block out device (optional) Provides a simple and secure method to control access to data or VL (Violet). For example, the part number ports while not in use for a blue 15-foot patch cord is UTPSP15BUY. For lengths 1 to 10 meters (one meter increments) and 0.5, 1.5, 2.5, 15, 20, meters, applications change the length designation in the part number to the desired length. For standard cable colors other than Off White, add suffix Mini-Com TX6 PLUS UTP Jack Modules are a support the following applications: BL (Black), BU (Blue), RD (Red), YL (Yellow), component of the TX6 PLUS UTP Copper Cabling GR (Green), OR (Orange) or VL (Violet). For Ethernet 10BASE-T, 100BASE-T (Fast example, the part number for a blue 15-meter System. This end-to-end system is interoperable and Ethernet), 1000BASE-T (Gigabit Ethernet) patch cord is UTPSP15MBUY. backwards compatible, providing design flexibility to To designate color other than Red, add 155 Mb/s ATM, 622 Mb/s ATM, 1.2 Gb/s ATM protect network investments well into the future. With suffix BL (Black), BU (Blue), YL (Yellow), GR (Green), OR (Orange), IW (Off White) or IG certified performance to the ANSI/TIA-568-C.2 Token Ring 4/16 (International Gray) at end of the part number. Category 6 and ISO 11801 Class E standards, this 10/package. Digital video and broadband/baseband system is ideal for today s high performance +To designate color other than IW (Off White), analog video workstation applications. With certified performance replace IW with EI (Electric Ivory), IG Voice over Internet Protocol (VoIP) (International Gray), BL (Black), BU (Blue), RD to the ANSI/TIA-568-C.2 Category 6 and ISO 11801 (Red), YL (Yellow), GR (Green), OR (Orange) Class E Edition 2.1 standards, these systems will or VL (Violet) in the part number. 100/package. Contact customer service for bulk packaged jack modules and patch cords. wwwwww.panduit.com.panduit.com Mini-Com TX6 PLUS UTP Jack Module Test Results Typical Test Results (dB) 20 MHz 100 MHz 200 MHz 250 MHz Performance Test Test Method NEXT > 68.0 > 54.0 > 48.0 > 46.0 PS NEXT > 64.0 > 50.0 > 44.0 > 42.0 Category 6 FEXT > 57.1 > 43.1 > 37.1 > 35.1 ANSI/TIA-568-C.2 PS FEXT > 54.1 > 40.1 > 34.1 > 32.2 Standard Attenuation < 0.10 < 0.20 < 0.28 < 0.32 Return Loss > 30 > 24.0 > 18.0 > 16.0 Consult technical support for cable brand specific channel test results. Mechanical Test Test Method Measurement Typical Test Results Load (grams) >100 Normal Force IEC 512-6d Circuit Resistance (mOhms) Vibration < 40 IEC 512-9a Circuit Resistance (mOhms) Durability < 40 IEC 512-13b Mating Force (N) < 20 Mating/Unmating Unmating Force (N) < 20 Electrical Test Test Method Measurement Typical Test Results Low Level Circuit Resistance IEC 512-2a Resistance (mOhms) < 40 Dielectric Withstand Voltage IEC 512-4a 1000 VAC, 1 minute Passed Insulation Resistance IEC 512-3a Resistance (MOhms) > 500 Environmental Test Test Method Measurement Typical Test Results Temperature Life IEC 512-9b Circuit Resistance (mOhms) < 40 Humidity IEC 512-11c Circuit Resistance (mOhms) < 40 Thermal Shock IEC 512-11d Circuit Resistance (mOhms) < 40 Climatic Sequence IEC 512-11a Circuit Resistance (mOhms) < 40 Flowing Mixed Gas Corrosion IEC 512-11g Circuit Resistance (mOhms) < 40 .71 18.08 Twist Preservation Cap .63 1.43 15.88 36.37 Module Housing Dimensions are in inches. Dimensions in brackets are metric . WORLDWIDE SUBSIDIARIES AND SALES OFFICES PANDUIT CANADA PANDUIT EUROPE LTD. PANDUIT SINGAPORE PTE. LTD. PANDUIT JAPAN PANDUIT LATIN AMERICA PANDUIT AUSTRALIA PTY. LTD. Markham, Ontario London, UK Republic of Singapore Tokyo, Japan Guadalajara, Mexico Victoria, Australia cs-cdn panduit.com cs-emea panduit.com cs-ap panduit.com cs-japan panduit.com cs-la panduit.com cs-aus panduit.com Phone: 800.777.3300 Phone: 44.20.8601.7200 Phone: 65.6305.7575 Phone: 81.3.6863.6000 Phone: 52.33.3777.6000 Phone: 61.3.9794.9020 For a copy of Panduit product warranties, log on to www.panduit.com/warranty For more information 2010 Panduit Corp. Visit us at www.panduit.com ALL RIGHTS RESERVED. Contact Customer Service by email: cs panduit.com WW-COSP14 or by phone: 800.777.3300 and reference COSP14 11/2010