Mini-Com TX6 PLUS UTP Jack Module SPECIFICA TION SHEET specifications TX6 PLUS UTP Category 6/Class E, 8-position, UTP jack module shall Copper Cabling System terminate solid, 4-pair, 24 22 AWG, 100 ohm unshielded twisted pair cable and shall not require use of a punchdown Mini-Com TX6 PLUS tool. UTP jack modules shall use a forward motion termination UTP Jack Module method to optimize performance by maintaining cable pair geometry while eliminating conductor untwist. The termination Jack module: CJ688TPIW* cap shall be color-coded white to designate Category 6 performance and shall include a universal label coded for TX6000 UTP Copper Cable T568A and T568B wiring schemes. Plenum: PUP6004** Riser: PUR6004** LSZH (60332-1): PUL6004** technical information LSZH (60332-3): PUZ6004** CM: PUC6004** Category 6/Class E channel Exceeds channel requirements of ANSI/TIA-568-C.2 Category 6 and component performance: and ISO 11801 Class E standards at swept frequencies TX6 PLUS UTP Patch Cords 1 to 250 MHz CM (foot lengths): UTPSP Y Exceeds component requirements of ANSI/TIA-568-C.2 Category 6 CM (meter lengths): UTPSP MY and ISO 11801 Class E standards at swept frequencies 1 to 250 MHz LSZH (meter lengths): UTPSPL MY FCC and ANSI compliance: Meets ANSI/TIA-1096-A contacts plated with 50 microinches of gold for superior performance Mini-Com Angled Modular Patch Panels PoE compliance: Rated for 2500 cycles with IEEE 802.3af / 802.3at and proposed 24-port, 1 RU: CPPLA24WBLY 802.3bt type 3 and type 4 48-port, 2 RU: CPPLA48WBLY IEC compliance: Meets IEC 60603-7 Mini-Com Flat Modular RoHS compliance: Compliant Patch Panels UL rated: UL 1863 approved 24-port, 1 RU: CPPL24WBLY Conductor Wire cap compatible with 24 22 AWG solid cable with conductor 48-port, 2 RU: CPPL48WBLY termination range: insulation diameters of 0.035 in. to 0.048 in. and overall cable O.D. For additional modular and punchdown 0.200 in. to 0.330 in. patch panels, visit www.panduit.com. Tools and Accessories key features and benefits Jack module 100% performance tested Confidence that each jack module will deliver the critical termination tool: CGJT electrical performance requirements Wire snipping tool: CWST Wire snipping tool: CJAST Utilizes enhanced Optimizes performance by eliminating conductor untwist and Giga-TX Technology reduces installation time and expense Clear dust cap: MDC-C Block out device: PSL-DCJB- Improved termination cap Conductor retention slots simplify jack module termination Phone icons: CIPIW-C+ Modular UTP jack modules snap in and out of all Mini-Com Faceplates, Data icons: CIDIW-C+ Modular Patch Panels and Surface Mount Boxes for easy moves, adds and changes *To designate color other than IW (Off White), replace IW suffix with EI (Electric Ivory), IG (International Gray), True strain relief Controls cable bend radius for long term installed performance WH (White), AW (Arctic White), BL (Black), BU (Blue), RD (Red), YL (Yellow), GR (Green), OR (Orange), Individually serialized Marked with quality control number for future traceability BR (Brown), GD (Gold), LB (Light Blue), PK (Pink), or RJ45 interface Industry standard interface provides a quick and easy plug and VL (Violet). play connection to RJ45 patch cords backwards compatible **To designate color, add suffix BU (Blue) or WH (White). For additional cable colors, contact customer Identification Can be clearly identified with optional labels and icons for service. port identification For lengths 1 to 20 feet (one foot increments) and 25, 30, 35, 40 feet, change the length designation in the Termination tools (optional) CGJT termination tool ensures conductors are fully terminated part number to the desired length. For standard cable by utilizing a smooth forward motion without impact on critical colors other than Off White, add suffix BL (Black), internal components for maximum reliability BU (Blue), RD (Red), YL (Yellow), GR (Green), OR (Orange) or VL (Violet). For example, the part number Block out device (optional) Provides a simple and secure method to control access to data for a blue 15-foot patch cord is UTPSP15BUY. ports while not in use For lengths 1 to 10 meters (one meter increments) and 0.5, 1.5, 2.5, 15, 20, meters, change the length designation in the part number to the desired length. applications For standard cable colors other than Off White, add suffix BL (Black), BU (Blue), RD (Red), YL (Yellow), GR (Green), OR (Orange) or VL (Violet). For example, Mini-Com TX6 PLUS UTP Jack Modules are a Class E standards, these systems will support the the part number for a blue 15-meter patch cord component of the TX6 PLUS UTP Copper Cabling following applications: is UTPSP15MBUY. System. This end-to-end system is interoperable and Ethernet 10BASE-T, 100BASE-T (Fast To designate color other than Red, add suffix BL backwards compatible, providing design flexibility to (Black), BU (Blue), YL (Yellow), GR (Green), OR Ethernet), 1000BASE-T (Gigabit Ethernet) protect network investments well into the future. With (Orange), IW (Off White) or IG (International Gray) at 155 Mb/s ATM, 622 Mb/s ATM, 1.2 Gb/s ATM end of the part number. 10/package. certified performance to the ANSI/TIA-568-C.2 Token Ring 4/16 +To designate color other than IW (Off White), replace Category 6 and ISO 11801 Class E standards, this Digital video and broadband/baseband IW with EI (Electric Ivory), IG (International Gray), BL system is ideal for today s high performance analog video (Black), BU (Blue), RD (Red), YL (Yellow), GR (Green), workstation applications. With certified performance OR (Orange) or VL (Violet) in the part number. Voice over Internet Protocol (VoIP) to the ANSI/TIA-568-C.2 Category 6 and ISO 11801 100/package. Contact customer service for bulk packaged jack www.panduit.com modules and patch cords. Mini-Com TX6 PLUS UTP Jack Module Test Results Typical Test Results (dB) Performance Test Test Method 20 MHz 100 MHz 200 MHz 250 MHz NEXT > 68.0 > 54.0 > 48.0 > 46.0 PS NEXT > 64.0 > 50.0 > 44.0 > 42.0 Category 6 NEXT > 57.1 > 43.0 > 37.1 > 35.1 ANSI/TIA-568-C.2 PS NEXT > 54.1 > 40.1 > 34.1 > 32.2 Standard Attenuation < 0.10 < 0.21 < 0.28 < 0.32 Return Loss > 30 > 24.0 > 18.0 > 16.0 Consult technical support for cable brand specific channel test results. Mechanical Test Test Method Measurement Typical Test Results Normal Force Load (grams) >100 IEC 512-6d Vibration Circuit Resistance (mOhms) < 40 IEC 512-9a Durability Circuit Resistance (mOhms) < 40 IEC 512-13b Mating/Unmating Mating Force (N) < 20 Un-mating Force (N) < 20 Electrical Test Test Method Measurement Typical Test Results Low Level Circuit Resistance IEC 512-2a Resistance (mOhms) < 40 Dielectric Withstand Voltage IEC 512-4a 1000 V, 1 minute Passed Insulation Resistance IEC 512-3a Resistance (MOhms) > 500 Environmental Test Method Measurement Typical Test Results Temperature Life IEC 512-9b Circuit Resistance (mOhms) < 40 Humidity IEC 512-11c Circuit Resistance (mOhms) < 40 Thermal Shock IEC 512-11d Circuit Resistance (mOhms) < 40 Climatic Sequence IEC 512-11a Circuit Resistance (mOhms) < 40 Flowing Mixed Gas Corrosion IEC 512-11g Circuit Resistance (mOhms) < 40 0.71 18.08 Twist Preservation Cap 0.63 1.43 15.88 36.37 Module Housing Dimensions are in inches. Dimensions in brackets are metric . WORLDWIDE SUBSIDIARIES AND SALES OFFICES PANDUIT CANADA PANDUIT EUROPE LTD. PANDUIT SINGAPORE PTE. LTD. PANDUIT JAPAN PANDUIT LATIN AMERICA PANDUIT AUSTRALIA PTY. LTD. Markham, Ontario London, UK Republic of Singapore Tokyo, Japan Guadalajara, Mexico Victoria, Australia cs-cdn panduit.com cs-emea panduit.com cs-ap panduit.com cs-japan panduit.com cs-la panduit.com cs-aus panduit.com Phone: 800.777.3300 Phone: 44.20.8601.7200 Phone: 65.6305.7575 Phone: 81.3.6863.6000 Phone: 52.33.3777.6000 Phone: 61.3.9794.9020 For a copy of Panduit product warranties, log on to www.panduit.com/warranty For more information 2015 Panduit Corp. Visit us at www.panduit.com ALL RIGHTS RESERVED. Contact Customer Service by email: cs panduit.com COSP235-WW-ENG or by phone: 800.777.3300 and reference COSP235 5/2016