TM specifications Small form factor fiber optic modules shall be compliant with the TIA FOCIS-6 Fiber Jack (FJ) NETWORK CONNECTIVITY GROUP interface specification. RJ-45 style module shall be field terminable in one module space with no SPEC SHEET adapter. The module shall contain a factory terminated pre-polished multimode fiber, requiring no field polishing and no adhesive. The fibers shall terminate in 2.5mm ferrules with a non- optical disconnect and typical insertion loss of 0.35dB per connector. MINI-COM OPTI-CRIMP FJ Fiber Optic Module Pre-polished Crimp technical information OPTI-CRIMP Multimode Module 62.5/125m: FJJSMM5C** Fiber compatibility: 3.0mm jacketed or 900m buffered, 62.5/125m and 50/125m: FJJSMM50C** 50/125m multimode OPTI-PLUG Fiber Optic Connector Ferrule type: Ceramic (Zirconia) with a pre-polished fiber stub Multimode: FJEPGM5C** Plug to Plug Coupler Insertion loss: 0.35dB typical Plug to plug coupler: FJGCCEI Return loss: Greater than 20dB (primarily used in testing) Pre-polished Termination Tooling key features and ...benefits Pre-polished crimp termination kit: FJMKIT Pre-polished fiber stub Eliminates polishing steps, speeding installation To upgrade from FJKITG, purchase FJQCVR fiber cleaver tool Mechanical crimp cable Consistently provides higher than industry standard cable OPTI-CRIMP Multimode Module retention retention requires no adhesive, speeding installation Pre-polished Replacement Ferrules Small form factor Double the port density in one module space 62.5/125m: FJJSMFRL-X connector at the outlet and in the telecommunications closet 50/125m: FJJSM50FRL-X Proven 2.5mm ferrules Uses standard termination tools and procedures Multimode Duplex Patch Cords OPTI-PLUG connector Robust design Protects fibers from mechanical and environmental stress to OPTI-PLUG connector: F D6P-6PM OPTI-PLUG connector Non-optical disconnect Maintains data transmission under tensile load to OPTI-JACK module: F D6P-6JM OPTI-PLUG connector RJ-45 form factor Familiar to end-users, snaps into all MINI-COM to SC: F D6P-3M outlets and modular patch panels OPTI-PLUG connector to ST: F D6P-2M Field terminable module Allows flexibility to assemble special length patch OPTI-PLUG connector and connector cords on site to FC: F D6P-4M OPTI-PLUG connector Adapterless Fewer components to order and inventory (Keyed W) to SC: F D6PW-3M OPTI-PLUG connector Flush mount Unused ports do not protrude from the wall can be (Keyed W) to ST: F D6PW-2M used with shuttered faceplates All key type (W, X, Y, Z) patch cords available Available in 62.5/125m (6) and 50/125m (5) TIA standardization FOCIS-6 interface approved for the TIA, required for Available in standard (1, 2, 3 and 10 meters) TIA/EIA-568-B.3 and custom lengths Keyed solution available Provides network security limits access to highly sensitive, **Substitute for classified and segregated networks Colors: EI = Electric Ivory BL = Black BU = Blue applications IW = Off White OR = Orange Fiber-to-the-desk: The pre-polished Keyed network security: Four color-coded, WH = White mechanical crimp version ofOPTI-JACK (FJ) keyed configurations of the module and Keyed Colors: WBL = Keyed W in Black fiber optic module is the ultimate desktop fiber connector are available to provide mechanical XRD = Keyed X in Red YOR = Keyed Y in Orange connector. The 2.5mm ferrule provides and visual differentiation to prevent ZYL = Keyed Z in Yellow robustness required for this demanding unintentional insertion into adjacent ports. X = Bag of 10 ferrules and crimp sleeves environment. The FJ interface module and Provides network security for military, connector design is familiar to the end user government, financial and educational and is polarized to prevent mismatch of applications. Universal keyed connector installer tip transmit and receive cables. Because there is available for testing purposes. no adapter, unused ports remain flush with Telecommunications closet: The high port the wall and away from damage. Shuttered density of the OPTI-CRIMP module reduces the Reduces faceplates can be used for further protection space requirements for fiber terminations in installation time of the unused ports. The modularity with the closet. This allows the end user to use over standard copper connectors allows for the complete less rack space and purchase fewer fiber OPTI-JACK modules data-communications solution to every enclosures. The multiple color options allow workstation in one outlet. color coding of different networks or areas of by 70%. the building for easier troubleshooting. Visit our website at: www.panduit.com/ncg MINI-COM OPTI-CRIMP FJ Fiber Optic Module Pre-polished Crimp Standards Compliant Connector Performance TIA ISO/IEC Performance Test Procedure and Description TIA/EIA-568-B.3 Required Performance 455 874-1 After Test 100 cycles -180 to 180 degrees <0.2dB 1 -- Flex max. insertion loss 0.75dB, min. return loss 20dB additional loss 8 drops from 1.8m <0.1dB 2 4.5.11 Impact max. insertion loss 0.75dB, min. return loss 20dB additional loss 4 days at 60C followed by post-conditioning FOTP-6 <0.2dB 4 4.5.18 High Temperature max. insertion loss 0.75dB, min. return loss 20dB additional loss 4 days at 90-95% RH and 40C <0.1dB 5 4.4.19 Humidity max. insertion loss 0.75dB, min. return loss 20dB max. change during test 0.4dB additional loss 11.24 lbs. at 0 degrees, 4.4 lbs. at 90 degrees <0.2dB 6 4.5.4 Cable Retention max. insertion loss 0.75dB, min. return loss 20dB max. change during test 0.5dB additional loss 500 mate/unmate cycles <0.1dB 21 4.5.32 Durability max. insertion loss 0.75dB, min. return loss 20dB additional loss 0.35dB 34 4.4.7 Insertion Loss max. insertion loss 0.75dB, min. return loss 20dB typical 10 cycles 2.5 cw, 5 ccw, 2.5 cw <0.1dB 36 4.5.5 Twist max. insertion loss 0.75dB, min. return loss 20dB additional loss 107 -- Return Loss 20dB minimum return loss >20dB 7.4 lbs. at 0 degrees <0.1dB 185 4.5.6 Coupling Strength max. insertion loss 0.75dB, min. return loss 20dB additional loss 4 days at 0C <0.1dB 188 4.5.17 Low Temperature max. insertion loss 0.75dB, min. return loss 20dB max. change during test 0.3dB additional loss NOTE: Above tests performed at 850 and 1300nm on 3.0mm jacketed fiber cable48 12.1 .53 13.4 .25 6.4 A & B DESIGNATION .25 2.17 6.4 UNDER BOOT AFTER ASSEMBLY 55.0 .48 .26 12.2 .71 6.6 18.0 1.96 49.7 .26 6.7 Keyed W - Black Keyed X - Red Keyed Y - Orange Keyed Z - Yellow Dimensions are in inches (Dimensions in parentheses are in millimeters) Our products are warranted to be free from defects in material and workmanship at the time of sale but our This warranty is made in lieu of and excludes all other warranties, expressed or implied. THE IMPLIED obligation under this warranty is limited to the replacement of any product proved to be defective within 6 WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR USE ARE SPECIFICALLY months (for product) or 90 days (for tools) from the date of delivery. Tool warranty is void if Panduit tools EXCLUDED. Neither seller nor manufacturer shall be liable for any other injury, loss or damage whether direct are modified, altered or misused in any way. Use of Panduit tooling with any product other than the specified or consequential, arising out of the use of, or the inability to use, the product. Panduit products for which the tool was designed, constitutes misuse. Before using, user shall determine The information contained in this literature is based on our experience to date and is believed to be reliable. the suitability of the product for his intended use and user assumes all risk and liability whatsoever in It is intended as a guide for use by persons having technical skill at their own discretion and risk. We do not connection therewith. guarantee favorable results or assume any liability in connection with its use. Dimensions contained herein are for reference purposes only. For specific dimensional requirements consult the factory. This publication is WORLD HEADQUARTERS not to be taken as a license to operate under, or a recommendation to infringe any existing patents. This PANDUIT CORP. supersedes and voids all previous literature, etc. Tinley Park, Illinois, USA Phone: 888-506-5400, ext. 6914 For Pricing and Further Information 708-532-1800, ext. 6914 Fax: 708-460-2897 Contact your local authorized NETWORK CONNECTIVITY GROUP Email: info panduit.com PANDUIT PAN-NET Distributor or Sales Office Internet: www.panduit.com/ncg PANDUIT CANADA EUROPEAN HEADQUARTERS ASIAN HEADQUARTERS PANDUIT CORP. PANDUIT MEXICO/LATIN AMERICA PANDUIT (AUST.) PTY. LTD. Div. of PANDUIT CORP. PANDUIT EUROPE LTD. PANDUIT SINGAPORE PTE. LTD. Japan Branch & CARIBBEAN Phone: (61) 3-9794 9020 Markham, Ontario London, UK Republic of Singapore Phone (81) (3) 3767-7011 Phone: (52) 3 666-2501 Phone: 905-475-6922 Phone: 44(0) 208-601-7200 Phone: (65) 379 6700 PANDUIT Corp. 2001 SA-NC09SP01A ALL RIGHTS RESERVED Printed in U.S.A. WORLDWIDE SUBSIDIARIES AND SALES OFFICES