ST OptiCam Pre-Polished Fiber Optic Connectors SPECIFICATION SHEET specifications ST pre-polished fiber optic connectors shall be TIA/EIA-604 FOCIS-2 compliant and contain a factory-terminated fiber, eliminating field polishing and adhesive. ST pre-polished connectors shall have an average insertion loss of 0.3dB per mated pair for multimode and ST OptiCam Pre-Polished Connectors singlemode fiber. ST pre-polished connectors shall captivate fiber with Zirconia Ceramic Ferrules and buffer in one action allowing for up to two re-terminations with 10Gig 50/125m (laser no degradation in performance. optimized) simplex: FSTMCXAQ 50/125m simplex: FSTMC5BL technical information 62.5/125m simplex: FSTMC6BL 9/125m simplex: FSTSCBU Standards requirements: TIA/EIA-604 FOCIS-2 compliant exceeds TIA/EIA-568-B.3 requirements ST OptiCam Pre-Polished Connectors with Composite Ferrules Fiber compatibility: 62.5/125m OM1, 50/125m OM2, 10Gig 50/125m laser optimized OM3/OM4 and 9/125m OS1/OS2 50/125m simplex: FSTMPC5BL Fiber size and type: 900m tight-buffered fiber 62.5/125m simplex: FSTMPC6BL 250m coated fiber, by using F250BT-C 250 micron fiber build-up OptiCam 1.6/2.0mm Boot Assemblies tube kit or FO6CB or FO12CB fan-out kit 10Gig multimode (aqua): FMCBT2AQ-X* Jacketed cable size: 1.6mm 2.0mm and 3.0mm jacketed cable with optional boots Multimode (black): FMCBT2BL-X Ferrule type: Zirconia ceramic or composite ferrule with a pre-polished fiber stub Singlemode (blue): FSCBT2BU-X Insertion loss: Ceramic: 0.3dB average (multimode and singlemode) OptiCam 3.0mm Boot Assemblies Composite: 0.3dB average (multimode) 10Gig multimode (aqua): FMCBT3AQ-X* Return loss: Ceramic: >20dB (multimode), >26dB (10Gig multimode), Multimode (black): FMCBT3BL-X >50dB (singlemode) Singlemode (blue): FSCBT3BU-X Composite: >20dB (multimode) *X = Bag of 10 Boots 100 per carton. key features and benefits OptiCam Termination Tooling OptiCam Termination Kit: FCAMKIT ST OptiCam Connectors OptiCam Conversion Kit Factory pre-polished fiber Eliminates inconsistent and time-consuming field polishing to deliver (upgrades Opti-Crimp stub endface required optical performance reduces termination time (less than Kit to also terminate half the time of field polish connectors) and the number of OptiCam Connectors): FPPKIT-CVY installation tools required Field Polish Kit Upgrade Dual cam design with Secures both the fiber and the buffer during the camming step to (upgrades Field Polish fiber and buffer clamps facilitate consistent termination results reduces the termination time Kit to also terminate compared to conventional termination methods OptiCam Connectors): FIELDKITUPG ST cradles (2 per pkg.): FSTC Allows up to two re-terminations to achieve optimum termination results reduces the number of rejected connectors and terminations Mini-Com ST Adapter Modules to provide yield rates approaching 100% for lower installed costs Multimode: CMST** Translucent Facilitates inspection of the fiber termination quality results in rapid Singlemode: CMSTZ** housing assembly installations, improved termination yields, and lower installed costs **Substitute for module color: EI = Electric Ivory, Mechanical cable retention Consistently provides higher than industry standard cable retention BU = Blue, BL = Black, IW = Off White, requires no adhesive, speeding installation AW = Arctic White. Choice of zirconia ceramic Provides material option with comparable performance to meet Opticom ST Fiber Adapter Panels or composite ferrules application requirements zirconia ceramic provides the highest durability 6 simplex MM adapters: FAP6WST for repeated matings 6 simplex SM adapters: FAP6WSTZ OptiCam Termination Tool 8 simplex MM adapters: FAP8WST Universal termination tool Secures both fiber and buffer in one action for all OptiCam Connectors 8 simplex SM adapters: FAP8WSTZ with connector specific cradles (included) ensures fast, consistent, and Opti-Core ST Patch Cords optimal terminations Duplex ST to ST: F D2-2MY Integrated visual Offers visual indication of proper termination after the cam step has Simplex ST to ST: F S2-2MY termination indicator (VTI) been completed virtually eliminates operator error to deliver a higher yield for a lower installed cost Duplex ST to SC: F D2-3MY Simplex ST to SC: F S2-3MY applications Add -C to simplex connector part numbers for bulk packs of 100 connectors. ST fiber optic connectors are widely used in fiber ST OptiCam Connectors eliminate the need for end Substitute for fiber type: 6 = 62.5/125m OM1, optic backbone and horizontal applications for face polishing and adhesive providing easier, faster 5 = 50/125m OM2, X = 10Gig 50/125m high-speed data transmission. Typical applications installation, especially in remote areas and confined OM3/OM4 or 9 = 9/125m OS1/OS2. for ST OptiCam Connectors include maintenance spaces. The hand-held OptiCam Termination Tool or emergency restoration of fiber networks and gives installers the flexibility to terminate in very Substitute for length in meters: 1, 2, 3, 5 or 10. retrofit/initial install in both behind-the-wall (BTW) close proximity to the application without having to Contact Customer Service for other and in the permanent side of panelized interconnect switch tools or find benchtop space. available lengths. and cross-connect. www.panduit.com ST OptiCam Pre-Polished Fiber Optic Connectors performance information Test Parameter Description Result Exceeds TIA/EIA-568-B.3 requirements Qualification test suite Complete testing protocol per TIA/EIA-568-B.3 (TIA/EIA-568-B.3 requirements) using TIA/EIA FOTPs that include mechanical, environmental, and optical test sequences Connector intermatability Dimensional and material compliance to All connectors are FOCIS compliant TIA/EIA standards with TIA/EIA-604-2-A Exceeds TIA/EIA-568-B.3 test requirements: Repeated mating 500 mate/unmate cycles <0.1dB additional insertion loss Max. insertion loss: 0.75dB Min. return loss: 20dB Cable retention (straight pull): TIA/EIA-568-B.3 requirement: Exceeds TIA/EIA-568-B.3 requirements: 0.5 lbs. load applied with <0.5dB increase in 1.0 lbs. avg. load applied with <0.2dB 900m tight-buffered fiber insertion loss after test increase in insertion loss after test Jacketed cable 11.24 lbs. load applied with <0.5dB increase in 11.24 lbs. load applied with <0.1dB increase insertion loss after test in insertion loss after test* *Jacketed cable retention tensile load may vary based on specific manufacturer s jacketed cable diameter and aramid yarn count. selection information Connector Ferrule Ferrule Backbone Boot Average Return Part Number Fiber Color Insertion Loss** Type Material Finish Color Loss Zirconia 10 GbE 50/125m FSTMCXAQ Simplex SPC Aqua Aqua 0.3dB >26dB Ceramic (laser optimized) OM3/OM4 Zirconia FSTMC5BL Simplex Ceramic 50/125m OM2 SPC Black Black 0.3dB >20dB FSTMPC5BL Simplex Composite Zirconia FSTMC6BL Simplex Ceramic Electric 62.5/125m OM1 SPC Black 0.3dB >20dB Ivory FSTMPC6BL Simplex Composite Zirconia FSTSCBU Simplex 9/125m OS1/OS2 UPC Blue Blue 0.3dB >50dB Ceramic **All connector insertion loss values calculated from tests taken with precision launch jumper assemblies per TIA/EIA-FOTP-171. OptiCam Boot Assemblies For 1.6/2.0mm Jacketed Cable ST OptiCam Pre-Polished OptiCam Termination Tool Simplex Connector .95 24.1 FSCBT2BU-X For 3.0mm Jacketed Cable 2.23 56.6 .95 FSTMC*** OCTT (Patch cords available separately 24.1 or in termination kits) FSCBT3BU-X ***Substitute for fiber type: For multimode, insert XAQ for 10Gig 50/125m, 5BL for 50/125m, or 6BL for 62.5/125m. For composite ferrules, insert a P after the M in the part number. For singlemode, insert BU for 9/125m, and replace M with S. Singlemode boot assembly part numbers (blue) are shown. For multimode boot assemblies, replace S (Singlemode) in part number with M (Multimode) and replace BU (Blue) with AQ (Aqua) or BL (Black). Dimensions are in inches Dimensions in brackets are in millimeters WORLDWIDE SUBSIDIARIES AND SALES OFFICES PANDUIT CANADA PANDUIT EUROPE LTD. PANDUIT SINGAPORE PTE. LTD. PANDUIT JAPAN PANDUIT LATIN AMERICA PANDUIT AUSTRALIA PTY. LTD. Markham, Ontario London, UK Republic of Singapore Tokyo, Japan Jalisco, Mexico Victoria, Australia cs-cdn panduit.com cs-emea panduit.com cs-ap panduit.com cs-japan panduit.com cs-la panduit.com cs-aus panduit.com Phone: 800.777.3300 Phone: 44.20.8601.7200 Phone: 65.6305.7575 Phone: 81.3.6863.6000 Phone: 52.33.3777.6000 Phone: 61.3.9794.9020 For a copy of Panduit product warranties, log on to www.panduit.com/warranty For more information 2009 Panduit Corp. Visit us at www.panduit.com ALL RIGHTS RESERVED. Contact Customer Service by email: cs panduit.com WW-FBSP22 or by phone: 800-777-3300 and reference FBSP22 9/2009