IndustrialNet M12 D-Code Field Terminable Plug SPECIFICATION SHEET specifications IndustrialNet M12 D-Code Industrial M12 D-Code Field Terminable Plug shall be applicable Field Terminable Plug for use in manufacturing as well as other industrial environments Field and shall meet or exceed the requirements of the ANSI/TIA-568-C.2 terminable plug: ISPS5E44MFA Category 5e, ISO 11801 Class D, and ODVA Ethernet/IP standards. The M12 D-Code plug shall be constructed of a zinc die cast IndustrialNet Category 5e SF/UTP housing with 360 shielding. The plug shall incorporate an ingress Copper Cable protection rating of IP65/IP67 and offer an extended temperature CM 2-pair: ISFCH5C02A*-XG range as required for more demanding applications. The plug Flame retardant, halogen-free shall be easily field attachable without any special tools and 2-pair/ shall be capable of termination to a 2-pair stranded or solid color Teal: ISFX5502ATL-LED twisted pair copper cable. The plug shall be capable of up to 10 2-pair/ re-terminations with the same gauge cable. color Red: ISFX5502ARD-LED IndustrialNet Category 6/5e RJ45 technical information Field Terminable Plug Electrical/ Exceeds channel and component requirements of Field mechanical performance: ANSI/TIA-568-C.2 Category 5e and ISO 11801 Class D standards terminable plug: ISPS688FA at swept frequencies up to 100MHz and meets ODVA Ethernet/IP IndustrialNet Category 5e electrical and mechanical performance requirements Shielded 600 V-Rated Patch Cords IEC compliance: Meets IEC 61076-2-101, IEC 60532-4, and IEC 60529 CM/CMX: **ISTPHCH1MTL IP compliance: Rated IP65 / IP67 IndustrialNet M12 D-Code to RJ45 Panel Mount Adapter UL compliance: UL 1977 recognized Panel RoHS compliancy status: Compliant mount adapter: ICAM12DRJS PoE compliance: Meets IEEE 802.3af and IEEE 802.3at for PoE applications Mini-Com Modular Patch Panel Temperature rating: -25C to 85C (-13F to 185F) operating and storage 8-port: CDPP8RG DIN Rail Adapter Wiring scheme: 4-position 1-port: CADIN1IW*** Conductor Stranded AWG 26/7-22/7 termination range: Solid AWG 26/1-22/1 *To designate color, add suffix TL (Teal), Insulation 1.1 2.1mm (0.043 0.079 inch) BL (Black), RD (Red), BU (Blue) termination range: GY (Gray), or YL (Yellow). **For other lengths, change the length Cable jacket 4.5 8.8mm (0.177 0.346 inch) designation (1M) of the part number to the diameter range: desired length (0.3M, 0.6M, 2M, 3M, 5M, or 10M) to designate color, replace TL (Teal) Packaging: 1 unit per polyethylene bag, 25 units per carton suffix with BL (Black), RD (Red), or YL (Yellow). For example, the part number of a 2-meter teal patch cord is ISTPHCH2MTL. key features and benefits ***For standard colors other than Off White, Robust construction Zinc die cast housing with 360 shielding for secure data replace IW in part number with BL (Black), transmission in high noise (EMI/RFI) environments provides EI (Electric Ivory), IG (International Gray), or WH (White). an ingress protection rating of IP65/IP67 for use in harsh environments Field attachable Can be terminated in seconds without any special tools and is re-terminable up to 10 times with the same gauge cable Extended -25C to 85C (-13F to 185F) temperature range applications IndustrialNet M12 D-Code Field Terminable housing and fully shielded, the plug is ideal for Plug provides an ideal solution to support use in high noise (EMI/RFI) environments. The Industrial Ethernet from the Local Area plug meets the ingress protection rating of Network (LAN) based support offices to the IP65/IP67 for use where wash downs are processing devices on the plant floor. A key common/required in the food and beverage component to the overall industrial Ethernet industry. The plug is easily field attachable for (10/100 Mbps) application, the plug is the on-site termination and also offers an extended interface that protects the integrity of the temperature range -25C to 85C (-13F to Ethernet data transfer from the switch or PLC 185F) for use in more demanding applications out to the devices or up to the horizontal plant such as manufacturing facilities where backbone. Constructed of a robust die cast temperature extremes are the norm. www.panduit.com IndustrialNet M12 D-Code Field Terminable Plug 2.07 52.6 M12 Thread Position 3 Position 4 0.39 9.8 0.417 10.60 0.59 0.77 15.0 19.5 Position 2 Position 1 0.67/17 Across Flats Dimensions are in inches. Dimensions in brackets are metric . WORLDWIDE SUBSIDIARIES AND SALES OFFICES PANDUIT US/CANADA PANDUIT EUROPE LTD. PANDUIT SINGAPORE PTE. LTD. PANDUIT JAPAN PANDUIT LATIN AMERICA PANDUIT AUSTRALIA PTY. LTD. Phone: 800.777.3300 London, UK Republic of Singapore Tokyo, Japan Guadalajara, Mexico Victoria, Australia Phone: 44.20.8601.7200 Phone: 65.6305.7575 Phone: 81.3.6863.6000 Phone: 52.33.3777.6000 Phone: 61.3.9794.9020 For a copy of Panduit product warranties, log on to www.panduit.com/warranty For more information 2016 Panduit Corp. Visit us at www.panduit.com/ia ALL RIGHTS RESERVED. iai panduit.com COSP338--WW-ENG 2/2016