ELECTRICAL SOLUTIONS A. System Overview Flex Conductor, Two-Hole, Long Barrel with Window Lug, 90 Angle For Use with Flexible, Extra-Flexible, and Code Stranded Copper Conductors B1. Cable Ties Type LCCX-F Can be used with code conductor and flex conductor class: G, H, I, Inspection window to visually assure full conductor insertion K, M and Diesel Locomotive Tin-plated to inhibit corrosion B2. Long barrel maximizes number of crimps and provides premium Cable UL Listed and CSA Certified to 35 KV** and temperature rated to wire pull-out strength and electrical performance Accessories 90C when crimped with Panduit and specified competitor Generously beveled wire entry prevents bent back strands when crimping tools and dies inserting conductor into barrel Meets J-STD-607-A and TIA-942 requirements for network B3. Color-coded barrels marked with Panduit and specified competitor systems grounding applications Stainless Steel Ties die index numbers for proper crimp die selection Available with NEMA hole sizes and spacing C1. INSPECTION W Wiring WINDOW Duct HOLE SPACING C2. T Surface Raceway 90 B C3. Abrasion L Protection Figure Dimensions Stud Stud Burndy T&B Wire C4. Flex Conductor Size (In.) Code Hole Hole Panduit Panduit Die Die Strip Std. Cable Class Diesel Conductor Size Spacing Color Die Index Index Index Length Pkg. Management Part Number G, H, I, K, M Locomotive Size (In.) (In.) W B T L Code No. No. No. (In.) Qty. LCCX8-10AF-L 10 .63 .41 .70 .08 1.53 Red P21 49 21 3/4 50 LCCX8-10BF-L 10 .75 .41 .70 .08 1.65 Red P21 49 21 3/4 50 D1. LCCX8-14AF-L 1/4 .63 .48 .70 .07 1.62 Red P21 49 21 3/4 50 Terminals 8 AWG 8 AWG 8 AWG LCCX8-14BF-L 1/4 .75 .48 .70 .07 1.74 Red P21 49 21 3/4 50 LCCX8-14DF-L 1/4 1.00 .48 .70 .07 1.99 Red P21 49 21 3/4 50 LCCX8-38DF-L D2. 3/8 1.00 .60 .70 .05 2.21 Red P21 49 21 3/4 50 Power LCCX6-10BF-L 10 .75 .46 1.07 .08 1.69 Blue P24 7 24 1 1/8 50 Connectors LCCX6-14AF-L 1/4 .63 .48 1.07 .08 1.66 Blue P24 7 24 1 1/8 50 LCCX6-14BF-L 1/4 .75 .48 1.07 .08 1.78 Blue P24 7 24 1 1/8 50 D3. LCCX6-14DF-L 1/4 1.00 .48 1.07 .08 2.03 Blue P24 7 24 1 1/8 50 6 AWG 6 AWG 6 AWG Grounding LCCX6-38AF-L 3/8 .63 .62 1.07 .06 1.88 Blue P24 7 24 1 1/8 50 Connectors LCCX6-38CF-L 3/8 .88 .62 1.07 .06 2.13 Blue P24 7 24 1 1/8 50 LCCX6-38DF-L 3/8 1.00 .62 1.07 .06 2.25 Blue P24 7 24 1 1/8 50 E1. LCCX4-14AF-L 1/4 .63 .55 1.05 .09 1.74 Gray P29 8 29 1 1/8 50 Labeling LCCX4-14BF-L Systems 1/4 .75 .55 1.05 .09 1.87 Gray P29 8 29 1 1/8 50 5, 4, 3 4 AWG 4 AWG LCCX4-38BF-L AWG 3/8 .75 .62 1.05 .08 2.09 Gray P29 8 29 1 1/8 50 LCCX4-38DF-L 3/8 1.00 .62 1.05 .08 2.34 Gray P29 8 29 1 1/8 50 E2. LCCX2-14AF-E* 1/4 .63 .70 1.36 .11 1.94 Brown P33 10 33 1 7/16 20 Labels LCCX2-14BF-E* 1/4 .75 .70 1.36 .11 2.06 Brown P33 10 33 1 7/16 20 2 AWG 2 AWG 2 AWG LCCX2-38DF-E* 3/8 1.00 .70 1.36 .11 2.51 Brown P33 10 33 1 7/16 20 E3. LCCX2-12F-E* 1/2 1.75 .75 1.36 .09 3.68 Brown P33 10 33 1 7/16 20 Pre-Printed LCCX1-14AF-X 1/4 .63 .76 1.44 .12 2.08 Green P37 11 37 1 1/2 10 & Write-On LCCX1-14BF-X Markers 1/4 .75 .76 1.44 .12 2.20 Green P37 11 37 1 1/2 10 LCCX1-14DF-X 1/4 1.00 .76 1.44 .12 2.45 Green P37 11 37 1 1/2 10 1 AWG 1 AWG 1 AWG LCCX1-56CF-X E4. 5/16 .88 .76 1.44 .12 2.38 Green P37 11 37 1 1/2 10 Permanent LCCX1-56DF-X 5/16 1.00 .76 1.44 .12 2.51 Green P37 11 37 1 1/2 10 Identification LCCX1-38DF-X 3/8 1.00 .76 1.44 .12 2.58 Green P37 11 37 1 1/2 10 LCCX1/0-14AF-X E5. 1/4 .63 .85 1.50 .13 2.22 Pink P42 12 42 1 9/16 10 Lockout/ LCCX1/0-14BF-X 1/4 .75 .85 1.50 .13 2.34 Pink P42 12 42 1 9/16 10 Tagout 1/0 AWG 1/0 AWG 1/0 AWG LCCX1/0-38DF-X 3/8 1.00 .85 1.50 .13 2.66 Pink P42 12 42 1 9/16 10 & Safety Solutions LCCX1/0-12F-X 1/2 1.75 .85 1.50 .13 3.82 Pink P42 12 42 1 9/16 10 See pages D3.70 D3.73 F. for tool and die information. Index *Not UL Listed or CSA Certified with Class K flex conductor when crimped with Burndy tools. **Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 V. Order number of pieces required, in multiples of Standard Package Quantity. Prime items appear in BOLD.ELECTRICAL SOLUTIONS A. System Overview Flex Conductor, Two-Hole, Long Barrel with Window Lug, 90 Angle (continued) B1. Cable Ties Figure Dimensions Stud Stud Burndy T&B Wire Flex Conductor Size (In.) Code Hole Hole Panduit Panduit Die Die Strip Std. Class Diesel Conductor Size Spacing Color Die Index Index Index Length Pkg. B2. Part Number G, H, I, K, M Locomotive Size (In.) (In.) W B T L Code No. No. No. (In.) Qty. Cable LCCX2/0-14AF-X 1/4 .63 .96 1.50 .13 2.29 Black P45 13 45 1 9/16 10 Accessories LCCX2/0-14BF-X 1/4 .75 .96 1.50 .13 2.42 Black P45 13 45 1 9/16 10 2/0 AWG 2/0 AWG 2/0 AWG LCCX2/0-38DF-X 3/8 1.00 .96 1.50 .13 2.73 Black P45 13 45 1 9/16 10 B3. LCCX2/0-12F-X 1/2 1.75 .96 1.50 .13 3.89 Black P45 13 45 1 9/16 10 Stainless Steel Ties LCCX3/0-14BF-X 1/4 .75 1.06 1.56 .14 2.50 Orange P50 14 50 1 5/8 10 3/0 AWG 3/0 AWG 3/0 AWG LCCX3/0-38DF-X 3/8 1.00 1.06 1.56 .14 2.84 Orange P50 14 50 1 5/8 10 LCCX4/0-14BF-X 1/4 .75 1.19 2.24 .16 2.69 Purple P54 15 54 2 5/16 10 C1. Wiring LCCX4/0-38DF-X 3/8 1.00 1.19 2.24 .16 2.88 Purple P54 15 54 2 5/16 10 4/0 AWG 4/0 AWG 4/0 AWG Duct LCCX4/0-12F-X 1/2 1.75 1.19 2.24 .16 4.06 Purple P54 15 54 2 5/16 10 LCCX250-14BF-X 1/4 .75 1.28 2.24 .17 2.46 Yellow P62 16 62 2 5/16 10 250 kcmil 262.6 kcmil LCCX250-38DF-X 3/8 1.00 1.28 2.24 .17 2.94 Yellow P62 16 62 2 5/16 10 C2. Surface LCCX300-38DF-6 300 kcmil 313.1 kcmil 3/8 1.00 1.39 2.30 .18 3.02 Red P71 18 71H 2 3/8 6 Raceway LCCX350-14BF-6 1/4 .75 1.54 2.50 .22 2.65 Blue P76 19 76H 2 9/16 6 LCCX350-38DF-6 3/8 1.00 1.54 2.50 .22 3.13 Blue P76 19 76H 2 9/16 6 350 kcmil 373.7 kcmil C3. LCCX350-12F-6 1/2 1.75 1.54 2.50 .22 4.31 Blue P76 19 76H 2 9/16 6 Abrasion See pages D3.70 D3.73 for tool and die information. Protection *Not UL Listed or CSA Certified with Class K flex conductor when crimped with Burndy tools. **Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 V. C4. NEMA hole sizes and spacing. Cable Management Flex Conductor, Two-Hole, Long Barrel with Window, Narrow Tongue Lug D1. For use with Flexible and Extra-Flexible Stranded Copper Copper Conductors Terminals Narrow tongue width for limited space applications Inspection window to visually assure full conductor insertion Can be used with flex conductor class: G, H, I, K, M and Diesel Tin-plated to inhibit corrosion D2. Locomotive UL Listed and CSA Certified to 35 KV** and temperature rated to Power Long barrel maximizes number of crimps and provides premium 90C when crimped with Panduit and specified competitor Connectors wire pull-out strength and electrical performance crimping tools and dies Generously beveled wire entry prevents bent back strands when Meets J-STD-607-A and TIA-942 requirements for network D3. inserting conductor into barrel systems grounding applications Grounding Color-coded barrels marked with Panduit and specified competitor Available with NEMA hole sizes and spacing Connectors die index numbers for proper crimp die selection E1. W Labeling Systems HOLE SPACING L E2. Labels B INSPECTION WINDOW E3. Pre-Printed T & Write-On Markers Figure Dimensions Stud Stud Burndy T&B Wire E4. Flex Conductor Size (In.) Hole Hole Panduit Panduit Die Die Strip Std. Permanent Class Diesel Size Spacing Color Die Index Index Index Length Pkg. Identification Part Number G,H, I, K, M Locomotive (In.) (In.) W B T L Code No. No. No. (In.) Qty. LCCXN450-12-6 450 kcmil 444.4 kcmil 1/2 1.75 1.19 2.69 0.33 6.41 Brown P87 20 87H 2 3/4 6 E5. Lockout/ LCCXN500-12-6 500 kcmil 535.3 kcmil 1/2 1.75 1.30 2.88 0.32 6.71 Pink P99 L99 99H 2 15/16 6 Tagout LCCXN650-12-6 646.4 kcmil 1/2 1.75 1.35 2.94 0.36 6.78 Black P106 24 106 3 6 & Safety Solutions See pages D3.70 D3.73 for tool and die information. **Consult cable manufacturer for voltage stress relief instructions with applications greater than 2000 V. F. NEMA hole sizes and spacing. Index For technical assistance in the U.S., call 866-405-6654 (outside the U.S., see inside back cover for directory) D2.95