NetKey Category 6 Punchdown Jack Modules DATA SHEET specifications NetKey Network Components Category 6/Class E, 8-position keystone jack module terminates unshielded twisted 4-pair, 22 26 AWG, 100 NetKey Category 6 Jack Modules ohm cable. Punchdown tool properly terminates each Module: NK688M* conductor for optimum performance. Universal label is Convenience color-coded T568A and T568B wiring schemes. pack of 25 modules: NK688M*-Q NetKey Category 6 Patch Cords Foot lengths: NK6PC3**Y Meter lengths: NK6PC1M Y NetKey Modular Patch Panels technical information 24-port, 1 RU: NKPP24P Category 6/Class Exceeds ANSI/TIA-568-C.2 Category 6 and ISO 11801 Class E 48-port, 2 RU: NKPP48P E channel and channel requirements at swept frequencies up to 250 MHz Termination and Cable Prep Tools component performance: Exceeds ANSI/TIA-568-C.2 and ISO 11801 Category 6 Punchdown tool: PDT110 component requirements at swept frequencies up to 250 MHz Punchdown base: NKSPB Meets with ANSI/TIA-1096-A contacts plated with 50 microinches + FCC and ANSI compliance: JackRapid of gold for superior performance Termination Tool: JR-PAN-2 Cable Meets IEC 60603-7 and IEC 60512-99-001 IEC compliance: snipping tool: CWST Cable Rated for 2500 cycles with IEEE 802.3af/802.3at and proposed PoE compliance: stripping tool: CJAST 802.3bt type 3 and type 4 cULus Listed UL 1863 and CAN/CSA-C22.2 (UL File E129886) Safety compliance: *To designate a color, add suffix IW (Off White), EI (Electric Ivory), IG (Intl Gray), Operating temperature: -10C to 65C (14F to 149F) WH (White), BL (Black), OR (Orange), RD (Red), BU (Blue), GR (Green) or YL (Yellow). RoHS compliance: Compliant **For standard lengths other than 3 feet (5, 7,10, 14 or 20) change the length designation in part number to the desired length. For standard cable colors other than Off White, add suffix BU (Blue), GR (Green), RD (red) or YL (Yellow) before the Y at the key features and benefits end of the part number. For example, the part number for a blue 5 foot patch cord is Confidence that each jack module delivers the specified 100% performance tested NK6PC5BUY. performance For standard lengths other than 1 meter (2, 3, 4 or 5) change the length designation 110 style punchdown Utilizes industry standard termination style and includes a wire in part number to the desired length. For retention cap termination standard cable colors other than Off White, add suffix BU (Blue), GR (Green), RD (Red) Universal keystone jack modules snap in and out of all NetKey Modular or YL (Yellow) before the Y at the end of the Faceplates, Modular Patch Panels, and Surface Mount Boxes for part number. For example, the part number fast moves, adds, and changes for a blue 5 meter patch cord is NK6PC5MBUY. Terminates the NetKey Keystone Marked with quality control number for traceability Individually serialized Punchdown Jack Module and NetKey Patch Panel. Convenience packaging 25 jacks packaged in one easy to open container, eliminating the (optional) time to open each individual package and reducing on-site waste Terminates the NetKey Keystone Punchdown Jack Module. Fluke JackRapid ideal for high volume installations Termination Tool available through distribution. To locate the local office, visit www.flukenetworks.com/contact. +JackRapid is a trademark of Fluke Networks. applications Applications include: Ethernet 10BASE-T, 100BASE-T (Fast Ethernet), and 1000BASE-T (Gigabit Ethernet) 155 Mb/s ATM, 622 Mb/s ATM, 1.2 Gb/s ATM Token Ring 4/16 Voice over internet protocol (VoIP) www.panduit.com NetKey Category 6 Punchdown Jack Modules Test Results Mechanical Test Test Method Measurement Typical Test Results Normal Load (grams) > 100 Vibration IEC 512-6d Circuit Resistance (mOhms) < 40 Shock IEC 512-6c Contact Disturbance (microsecond) < 5 Durability IEC 512-6a Circuit Resistance (mOhms) < 20 Mating Force (N) < 20 Mating/Un-mating IEC 512-6b Un-mating Force (N) < 20 Termination Cycles IEC 352 Number of Cycles > 20 Mating Cycles IEC 60603-7 Number of Plug Insertions > 2500 Electrical Test Test Method Measurement Typical Test Results Low Level Circuit Resistance IEC 512-2a Resistance (mOhms) < 20 Dielectric Withstand Voltage IEC 512-4a 1000 V, 1 minute Passed Insulation Resistance IEC 512-3a Resistance (mOhms) > 500 Mechanical Test Test Method Measurement Typical Test Results Temperature Life IEC 512-9b Circuit Resistance (mOhms) < 40 Humidity IEC 512-11c Circuit Resistance (mOhms) < 40 Thermal Shock IEC 512-11d Circuit Resistance (mOhms) < 40 Climatic Sequence IEC 512-11a Circuit Resistance (mOhms) < 40 Flowing Mixed Gas Corrosion IEC 512-11g Circuit Resistance (mOhms) < 40 0.875 22.23 1.16 29.50 0.645 16.38 Dimensions are in inches Dimensions in brackets are metric WORLDWIDE SUBSIDIARIES AND SALES OFFICES PANDUIT CANADA PANDUIT EUROPE LTD. PANDUIT SINGAPORE PTE. LTD. PANDUIT JAPAN PANDUIT LATIN AMERICA PANDUIT AUSTRALIA PTY. LTD. Markham, Ontario London, UK Republic of Singapore Tokyo, Japan Guadalajara, Mexico Victoria, Australia cs-cdn panduit.com cs-emea panduit.com cs-ap panduit.com cs-japan panduit.com cs-la panduit.com cs-aus panduit.com Phone: 800.777.3300 Phone: 44.20.8601.7200 Phone: 65.6305.7575 Phone: 81.3.6863.6000 Phone: 52.33.3777.6000 Phone: 61.3.9794.9020 For a copy of Panduit product warranties, log on to www.panduit.com/warranty For more information 2016 Panduit Corp. Visit us at www.panduit.com ALL RIGHTS RESERVED. Contact Customer Service by email: cs panduit.com NKDS28--WW-ENG or by phone: 800.777.3300 2016-09-26